Skip to content

TCL vs Viessmann heat pumps

Measured against models of the same size and duct type, Viessmann scores higher on 5 of the 6 ratings. TCL has 192 outdoor models, Viessmann has 43 outdoor models. TCL and Viessmann have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
TCL and Viessmann on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Viessmann scores higher on 5 of the 6 ratings.
  • TCL
  • Viessmann
  • Other ranked manufacturers
TCLViessmann

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingTCLViessmann
Efficiency index50%median —60%median —
COP at 5°F36%median 1.8953%median 2.00
Capacity retention at 5°F52%median 75%73%median 88%
HSPF253%median 9.574%median 9.5
SEER259%median 20.059%median 17.0
EER241%median 11.250%median 11.0
Heating capacity at 5°F52%median 17,000 Btu/h74%median 25,000 Btu/h
Outdoor models19243
AHRI certifications701171

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardTCLViessmann
CEE 2025 Tier 1 (Split ASHP)75%144 models83.7%36 models
CEE 2026 Tier 1 (Split ASHP)75%144 models83.7%36 models
CEE Advanced Tier (Split ASHP)0%0 models4.7%2 models
Xcel Energy Colorado cold-climate ASHP (2025)71.9%138 models79.1%34 models
DOE Cold Climate Heat Pump Challenge0%0 models4.7%2 models
ENERGY STAR Cold Climate64.6%124 models69.8%30 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • TCL
  • Viessmann
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeTCLViessmann
Ducted, up to 1.5 tons12 · index 59%8 · index 68%
Ducted, 2 tons12 · index 49%7 · index 59%
Ducted, 2.5 to 3 tons21 · index 58%16 · index 55%
Ducted, 3.5 to 4.5 tons22 · index 50%11 · index 57%
Non-ducted, up to 1.5 tons95 · index 50%5 · index 78%
Non-ducted, 2 tons20 · index 43%2 · index 80%
Non-ducted, 2.5 to 3 tons29 · index 48%6 · index 58%
Non-ducted, 3.5 to 4.5 tons12 · index 46%4 · index 52%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeTCLCold-climate score, best modelViessmannCold-climate score, best model
Ducted, up to 1.5 tons68.6(50 is the typical model of its size class)THH18TEI2NAG0F24with ducted air handler THH18IEI2NAG0F24Also listed as H18TDHXPC12 of 12 models qualify · AHRI 21808309187.0(50 is the typical model of its size class) (higher)D5CUHAH18AAKwith ducted air handler D5MUWAQ18XA37 of 8 models qualify · AHRI 218668521
Ducted, 2 tons69.6(50 is the typical model of its size class)H24TDHXPCwith ducted air handler H24FAHUDE11 of 12 models qualify · AHRI 21833248385.8(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK7 of 7 models qualify · AHRI 217178805
Ducted, 2.5 to 3 tons67.2(50 is the typical model of its size class)THH30TEI2NAG0F24with ducted air handler THH30IEI2NAG0F24Also listed as H30TDHXPC19 of 21 models qualify · AHRI 21808287783.6(50 is the typical model of its size class) (higher)D5CMHAH36EAK11 of 16 models qualify · AHRI 217178827
Ducted, 3.5 to 4.5 tons69.4(50 is the typical model of its size class)H48SDH20XQCwith ducted air handler H48APH20UDEAlso listed as THH48HDI2NAJ0H2622 of 22 models qualify · AHRI 21845381982.6(50 is the typical model of its size class) (higher)D5CMHAH48FAK10 of 11 models qualify · AHRI 217178830
Non-ducted, up to 1.5 tons72.4(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2571 of 95 models qualify · AHRI 21802841397.0(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK5 of 5 models qualify · AHRI 217178781
Non-ducted, 2 tons63.4(50 is the typical model of its size class)TSH24HDI2NAN0T26with ductless indoor unit TSH24IDI2NAN0T26Also listed as H24SBH23XQC12 of 21 models qualify · AHRI 21808286490.1(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ductless indoor unit D5FSCAH24XAK2 of 2 models qualify · AHRI 217178803
Non-ducted, 2.5 to 3 tons68.7(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2519 of 28 models qualify · AHRI 21802841489.4(50 is the typical model of its size class) (higher)D5CLHAH36AAKwith ductless indoor unit D5FCFAH36XAK4 of 6 models qualify · AHRI 217178810
Non-ducted, 3.5 to 4.5 tons48.5(50 is the typical model of its size class)TMH48HEI2NAS0U2511 of 12 models qualify · AHRI 21802841675.6(50 is the typical model of its size class) (higher)D5CMHAH48FAK4 of 4 models qualify · AHRI 217178831

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeTCLAll-around score, best modelViessmannAll-around score, best model
Ducted, up to 1.5 tons73.5(50 is the typical model of its size class)TMH18HEI2NAS0U25*Also listed as H18FMHD3XPC12 of 12 models have all five ratings · AHRI 21862504687.8(50 is the typical model of its size class) (higher)D5CSHAH09AAKwith ducted air handler D5FSDAH12XAK8 of 8 models have all five ratings · AHRI 217178787
Ducted, 2 tons70.1(50 is the typical model of its size class)H24SDH20XQCwith ducted air handler H24APH20UDEAlso listed as THH24HDI2NAJ0H2614 of 14 models have all five ratings · AHRI 21845381580.3(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK7 of 7 models have all five ratings · AHRI 217178805
Ducted, 2.5 to 3 tons80.6(50 is the typical model of its size class)TMH27HEI2NAS0U25*Also listed as H27FMHD4XPC19 of 19 models have all five ratings · AHRI 21862504785.6(50 is the typical model of its size class) (higher)D5CMHAH30EAK16 of 16 models have all five ratings · AHRI 217178824
Ducted, 3.5 to 4.5 tons66.2(50 is the typical model of its size class)TMH42HDI2NAO0U25Also listed as TMH42HDI2NAO0U2522 of 22 models have all five ratings · AHRI 21846778685.0(50 is the typical model of its size class) (higher)D5CMHAH48FAK11 of 11 models have all five ratings · AHRI 217178830
Non-ducted, up to 1.5 tons83.7(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2585 of 96 models have all five ratings · AHRI 21802841396.9(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK5 of 5 models have all five ratings · AHRI 217178781
Non-ducted, 2 tons67.0(50 is the typical model of its size class)TSH24HDI2NAN0T26with ductless indoor unit TSH24IDI2NAN0T26Also listed as H24SBH23XQC18 of 19 models have all five ratings · AHRI 21808286480.5(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ductless indoor unit D5FSHAH24XAK2 of 2 models have all five ratings · AHRI 217178802
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2528 of 29 models have all five ratings · AHRI 21802841485.8(50 is the typical model of its size class) (higher)D5CMHAH30EAK6 of 6 models have all five ratings · AHRI 217178823
Non-ducted, 3.5 to 4.5 tons70.2(50 is the typical model of its size class)TMH48HEI2NAS0U2512 of 12 models have all five ratings · AHRI 21802841676.6(50 is the typical model of its size class) (higher)D5CMHAH48FAK4 of 4 models have all five ratings · AHRI 217178829

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingTCLViessmann
COP at 5°Fbeats 88% · 2.25TSH24HDI2NAL0B25Also listed as H24SVH20XQCNon-ducted, 2 tonsbeats 97% · 2.40D5CSHAH06AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 125%H24TDHXPCDucted, 2 tonsbeats 100% · 116%D5CMHAH30EAKNon-ducted, 2.5 to 3 tons
HSPF2beats 96% · 10.5TMH36HEI2NAM5U24Also listed as H36FMH21XPCDucted, 2.5 to 3 tonsbeats 99% · 14.8D5CSHAH06AAKNon-ducted, up to 1.5 tons
SEER2beats 100% · 22.0TMH27HEI2NAS0U25*Also listed as H27FMHD4XPCDucted, 2.5 to 3 tonsbeats 99% · 20.5D5CMHAH48FAKDucted, 3.5 to 4.5 tons
EER2beats 97% · 14.0TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U25Non-ducted, 2.5 to 3 tonsbeats 99% · 18.0D5CSHAH06AAKNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 30,000 Btu/hH24TDHXPCDucted, 2 tonsbeats 98% · 19,600 Btu/hD5CUHAH18AAKDucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
TCL vs Viessmann: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • TCL (median, middle 50%)
  • Viessmann (median, middle 50%)
Heating capacity, % of its 47°F maximum70%76%COP at maximum capacity1.902.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
TCL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TCL, 47°F110100%100%100%100%100%
TCL, 17°F11067%72%74%82%92%
TCL, 5°F11058%65%70%72%77%
TCL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TCL, 47°F1102.52.83.013.53.71
TCL, 17°F1101.992.092.22.32.47
TCL, 5°F1101.81.81.922.03
Viessmann: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Viessmann, 47°F39100%100%100%100%100%
Viessmann, 17°F3969%78%79%86%90%
Viessmann, 5°F3959%70%76%82%83%
Viessmann: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Viessmann, 47°F392.983.13.243.453.58
Viessmann, 17°F392.022.162.292.422.61
Viessmann, 5°F391.841.9222.12.15

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter