Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Trane vs York heat pumps
Measured against models of the same size and duct type, York scores higher on 3 of the 6 ratings. Trane has 363 outdoor models, York has 229 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Trane
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Trane | York |
|---|---|---|
| Efficiency index | 50%median — · 19th ranked | 54%median — · 14th ranked |
| COP at 5°F | 68% (higher)median 2.24 · 1st ranked | 67% (higher)median 2.16 · 2nd ranked |
| Capacity retention at 5°F | 43%median 65% · 24th ranked | 51%median 70% · 14th ranked |
| HSPF2 | 36%median 7.5 · 27th ranked | 44%median 8.0 · 20th ranked |
| SEER2 | 40%median 15.5 · 25th ranked | 40%median 15.2 · 26th ranked |
| EER2 | 66% (higher)median 11.7 · 3rd ranked | 57% (higher)median 11.7 · 10th ranked |
| Heating capacity at 5°F | 44%median 21,800 Btu/h · 24th ranked | 53%median 20,000 Btu/h · 14th ranked |
| Outdoor models | 363 | 229 |
| AHRI certifications | 84,774 | 94,251 |
Share of models meeting each standard
| Standard | Trane | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 38.6%140 models | 52.8%121 models |
| CEE 2026 Tier 1 (Split ASHP) | 36.6%133 models | 52.8%121 models |
| CEE Advanced Tier (Split ASHP) | 2.5%9 models | 7.9%18 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 25.6%93 models | 38.9%89 models |
| DOE Cold Climate Heat Pump Challenge | 2.5%9 models | 7.9%18 models |
| ENERGY STAR Cold Climate | 17.9%65 models | 35.4%81 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Trane
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Trane | York |
|---|---|---|
| Ducted, up to 1.5 tons | 18 · index 46% | 22 · index 54% |
| Ducted, 2 tons | 42 · index 44% | 20 · index 49% |
| Ducted, 2.5–3 tons | 102 · index 49% | 59 · index 50% |
| Ducted, 3.5–4.5 tons | 131 · index 53% | 69 · index 49% |
| Ducted, 5 tons and up | 46 · index 49% | 13 · index 42% |
| Non-ducted, up to 1.5 tons | 15 · index 53% | 43 · index 62% |
| Non-ducted, 2 tons | 4 · index 42% | 16 · index 63% |
| Non-ducted, 2.5–3 tons | 7 · index 56% | 15 · index 53% |
| Non-ducted, 3.5–4.5 tons | 3 · index 63% | 5 · index 54% |
| Non-ducted, 5 tons and up | 2 · index 68% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | TraneCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 92.5(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB5 of 20 models qualify · AHRI 216794262 | 80.4(50 is the typical model of its size class)YPAS18BLFASDQ1with ducted air handler YPPIMB18UFA1DQ9 of 20 models qualify · AHRI 218694255 |
| Ducted, 2 tons | 90.0(50 is the typical model of its size class)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A115 of 40 models qualify · AHRI 218792275 | 90.2(50 is the typical model of its size class) (higher)HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDR12 of 22 models qualify · AHRI 218026253 |
| Ducted, 2.5–3 tons | 84.6(50 is the typical model of its size class)5TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCB24 of 102 models qualify · AHRI 216797087 | 92.3(50 is the typical model of its size class) (higher)HH836E2S11with indoor coil D(A,C,E)36A4K+TDR and furnace Z9ET080C16SMPS122 of 61 models qualify · AHRI 218350129 |
| Ducted, 3.5–4.5 tons | 93.0(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP38 of 131 models qualify · AHRI 216794596 | 90.4(50 is the typical model of its size class)HH860E2S11with ducted air handler DM59A4K+JMC20D2SN1+TDR18 of 67 models qualify · AHRI 218026269 |
| Ducted, 5 tons and up | 81.1(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025 | 63.4(50 is the typical model of its size class)PH9E60N00D212 of 13 models qualify · AHRI 218450295 |
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082 | 91.6(50 is the typical model of its size class) (higher)YPAS18BLFASDQ1with ductless indoor unit YPCIB18UFA1DQ36 of 43 models qualify · AHRI 218694256 |
| Non-ducted, 2 tons | 37.7(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437 | 96.3(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ13 of 16 models qualify · AHRI 218694257 |
| Non-ducted, 2.5–3 tons | 73.8(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026 | 97.5(50 is the typical model of its size class) (higher)YPAS30BLFASDQ1with ductless indoor unit YPCIB30UFA1DQ11 of 15 models qualify · AHRI 218694248 |
| Non-ducted, 3.5–4.5 tons | 67.2(50 is the typical model of its size class) (higher)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027 | 59.1(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPPFCB48UFA1DQ3 of 5 models qualify · AHRI 218696687 |
| Non-ducted, 5 tons and up | 64.1(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028 | No models in this size class |
All-around best
| Size and duct type | TraneAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 84.4(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP17 of 17 models have all five ratings · AHRI 216794699 | 80.3(50 is the typical model of its size class)YPAS12BLFASDQ1with ducted air handler YPPIMB12UFA1DQ21 of 21 models have all five ratings · AHRI 218694251 |
| Ducted, 2 tons | 86.7(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A131 of 31 models have all five ratings · AHRI 218792275 | 77.6(50 is the typical model of its size class)HH824E2S11with ducted air handler D(A,C,E)36A4K+JME08B2SN1+TDR25 of 25 models have all five ratings · AHRI 218026254 |
| Ducted, 2.5–3 tons | 88.5(50 is the typical model of its size class)5TWV0X36A1with indoor coil 5PX*D010AS3 and furnace S8V2D120M5PDBAlso sold as American Standard 5A6V0X36A171 of 107 models have all five ratings · AHRI 216453109 | 91.1(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ducted air handler YPPIMB30UFA1DQ39 of 55 models have all five ratings · AHRI 218694240 |
| Ducted, 3.5–4.5 tons | 88.9(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP102 of 138 models have all five ratings · AHRI 216794476 | 85.7(50 is the typical model of its size class)HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDR44 of 68 models have all five ratings · AHRI 218014963 |
| Ducted, 5 tons and up | 74.7(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025 | 70.1(50 is the typical model of its size class)PH9E60N00D216 of 14 models have all five ratings · AHRI 218450295 |
| Non-ducted, up to 1.5 tons | 72.2(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082 | 89.2(50 is the typical model of its size class) (higher)YRACXJ12WHAAwith ductless indoor unit YRAKXJ12PHAA43 of 43 models have all five ratings · AHRI 218037193 |
| Non-ducted, 2 tons | 48.8(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437 | 84.5(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ16 of 16 models have all five ratings · AHRI 218694257 |
| Non-ducted, 2.5–3 tons | 76.2(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026 | 85.0(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ductless indoor unit YPCIB30UFA1DQ15 of 15 models have all five ratings · AHRI 218694244 |
| Non-ducted, 3.5–4.5 tons | 73.9(50 is the typical model of its size class) (higher)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027 | 60.5(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPCIB48UFA1DQ5 of 5 models have all five ratings · AHRI 218694246 |
| Non-ducted, 5 tons and up | 67.9(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Trane | York |
|---|---|---|
| COP at 5°F | beats 100% · 3.205TWR4036A1Ducted, 2.5–3 tons | beats 100% · 3.55UPC24CN23STG1Ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 136%5A6H7036A1Ducted, 2.5–3 tons | beats 100% · 123%YRACXJ24WHBANon-ducted, 2 tons |
| HSPF2 | beats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5–3 tons | beats 100% · 12.0YPAS30BUFASDQ1Non-ducted, 2.5–3 tons |
| SEER2 | beats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5–3 tons | beats 100% · 22.0YH960E2C11Also sold as Coleman XH960E2C11Ducted, 3.5–4.5 tons |
| EER2 | beats 99% · 14.43TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAANon-ducted, 2.5–3 tons | beats 99% · 14.4YPAS36BLFASDQ1Non-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons | beats 100% · 23,000 Btu/hYRACXJ18WHAAAlso listed as YRACXJ18WHBANon-ducted, up to 1.5 tons |