Skip to content

Ranked by COP at 5°F only: ducted systems, by size

Heating efficiency at 5°F outdoor temperature: units of heat delivered per unit of electricity. Ranked by this one rating only; the overall cold-climate verdict is on the cold-climate board. Inside one size and duct type the raw ratings are comparable, so these boards rank by the rating itself, and a manufacturer can hold more than one place. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

LeaderboardsData as of updated · sources

Ducted, up to 1.5 tons: ranked by COP at 5°F only

Ducted, up to 1.5 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
137MUHAQ18AA3CARRIERwith indoor coil D(A,C,E)31A3J+TDR and furnace 58SU*B080M21**20Carrier1.5 tons17,200 Btu/h · Ducted3.3083%9.514.811.016,700CEE 25CEE 26CEE AdvXcelDOEES CC1,623218330915
2HH824E2S11YORKwith indoor coil D(A,C,E)37E2J+TDR and furnace Y82E080B12LMPS1York1.5 tons20,600 Btu/h · Ducted3.2080%9.518.811.718,300CEE 25CEE 26CEE AdvXcelDOEES CC5,691217220152
337MUHAQ18AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier1.5 tons18,000 Btu/h · Ducted3.1883%8.516.011.015,600CEE 25CEE 26XcelES CC1,446218330891
4KUSXB181ALGwith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons16,800 Btu/h · Ducted3.1765%8.115.211.712,900CEE 25CEE 26XcelES CC99217198647
5RP15AY24AJ2NRUUDwith ducted air handler AEN+CM24C2J+TDRRheem1.5 tons20,600 Btu/h · Ducted3.05127%7.514.811.227,400Xcel230218694591
6KUSXA181ALGwith ducted air handler D(A,C,E)25C3D+TDRLG1.5 tons16,900 Btu/h · Ducted3.0165%8.115.211.213,000CEE 25CEE 26XcelES CC83217198610
75TWV0X24A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCBTrane1.5 tons19,800 Btu/h · Ducted2.99122%10.021.211.727,000CEE 25CEE 26CEE AdvXcelDOEES CC185216794262
8KUSXB241ALGwith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons20,400 Btu/h · Ducted2.9567%8.515.211.716,000CEE 25CEE 26CEE AdvXcelDOEES CC112217198651
95A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRPTrane1.5 tons19,500 Btu/h · Ducted2.9398%10.021.011.221,800CEE 25CEE 26XcelES CC167217117128
10SUZ-AA18NL***Mitsubishi Electric · M serieswith ducted air handler SEZ-AD18NLMitsubishi Electric1.5 tons18,000 Btu/h · Ducted2.9358%10.417.012.810,500CEE 25CEE 2612217232157

Ducted, up to 1.5 tons board

Ducted, 2 tons: ranked by COP at 5°F only

Ducted, 2 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1UPC24CN23STG1GUARDIANwith ducted air handler JHE24B5AC2SS1York2 tons24,000 Btu/h · Ducted3.5581%9.518.011.724,200CEE 25CEE 26XcelES CC34216409634
2KUSXA301ALGwith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons21,400 Btu/h · Ducted3.4361%8.515.211.715,900CEE 25CEE 26XcelES CC96217198620
337MURAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons23,400 Btu/h · Ducted3.1687%8.514.39.021,200CEE 25CEE 26XcelES CC3,264218331338
4NS18H24HA5***GE Applianceswith ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons22,400 Btu/h · Ducted3.1382%8.515.911.519,500CEE 25CEE 26CEE AdvXcelDOEES CC1,318217596950
537MUHAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons22,000 Btu/h · Ducted3.0698%8.515.59.820,800CEE 25CEE 26XcelES CC4,679218331062
6KUSXB301ALGwith ducted air handler D(A,C,E)31D3D+TDRLG2 tons26,000 Btu/h · Ducted3.0067%8.114.89.820,000CEE 25CEE 26XcelES CC132217198655
7248TAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17Carrier2 tons23,000 Btu/h · Ducted2.9051%8.117.513.012,900CEE 25CEE 261,821217676875
8D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRAlso listed as D5CURAH24AAKCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.09.819,500CEE 25CEE 26XcelES CC5,137217906665
95A6H7024A1AMERICAN STANDARDwith ducted air handler CM24D3J+TDRTrane2 tons21,000 Btu/h · Ducted2.87111%8.115.511.724,400CEE 25CEE 26XcelES CC732217155223
105TWR7024A1TRANEwith ducted air handler CM36B4J+TDRTrane2 tons21,600 Btu/h · Ducted2.85111%8.116.012.024,400CEE 25CEE 26XcelES CC553217754352

Ducted, 2 tons board

Ducted, 2.5 to 3 tons: ranked by COP at 5°F only

Ducted, 2.5 to 3 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
17HP14F30P-**ACONCORDwith indoor coil D(A,C,E)37A3K+TDR and furnace 97G2UH110CE20Lennox2.5 tons27,400 Btu/h · Ducted4.0662%7.515.513.016,000CEE 25CEE 262,082218807830
2NS21H36MA5-**AGEwith indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances2.5 tons31,400 Btu/h · Ducted4.0093%10.019.011.230,400CEE 25CEE 26XcelES CC166218792658
35TWR4036A1TRANEwith indoor coil DH60T4J and furnace *UHMC100CCV4Trane2.5 tons32,800 Btu/h · Ducted3.2076%7.514.311.720,400None1,642216952325
45A6H5036A1AMERICAN STANDARDwith indoor coil DH36T4J and furnace S9V2C100U5PSCTrane3 tons33,600 Btu/h · Ducted3.1970%9.016.312.022,200CEE 25CEE 26Xcel1,625217149038
55A6H4036A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace *UHMC100CCV4Trane2.5 tons32,800 Btu/h · Ducted3.1872%7.514.311.722,000None1,446217147162
6KUSXA422ALGwith ducted air handler D(A,C,E)42B4D+TDRLG3 tons37,600 Btu/h · Ducted3.1664%8.516.011.728,600CEE 25CEE 26XcelES CC70217198634
7KUSXB421ALGwith ducted air handler D(A,C,E)48D3D+TDRLG3 tons38,500 Btu/h · Ducted3.1167%8.515.211.728,800CEE 25CEE 26XcelES CC54217198667
8HH836E2S12COLEMANwith indoor coil D(A,C,E)37E3K+TDR and furnace Z8ET100C20LMPS1York2.5 tons32,000 Btu/h · Ducted3.1068%9.017.511.722,200CEE 25CEE 26XcelES CC7,330218772624
95TWR5036A1TRANEwith indoor coil DH60T4J and furnace S8V2B080M4PCBTrane3 tons33,200 Btu/h · Ducted3.0870%8.516.012.521,200CEE 25CEE 26Xcel2,232216952729
10HH836E2S11YORKwith indoor coil D(A,C,E)36B4K+TDR and furnace Y81E080C20LMPS1York3 tons33,200 Btu/h · Ducted3.0890%8.519.011.029,400CEE 25CEE 26CEE AdvXcelDOEES CC8,624217027554

Ducted, 2.5 to 3 tons board

Ducted, 3.5 to 4.5 tons: ranked by COP at 5°F only

Ducted, 3.5 to 4.5 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1KUSXA482ALGwith ducted air handler D(A,C,E)49C3D+TDRLG3.5 tons42,500 Btu/h · Ducted3.1765%9.016.011.732,600CEE 25CEE 26XcelES CC76217198644
25TWR4060A1TRANEwith indoor coil DH60T4J and furnace S8X1D120M5PSCTrane4.5 tons52,000 Btu/h · Ducted3.0970%7.514.311.034,400None428216953201
3SL22KLV-060-230A**LENNOXwith indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60CLennox4.5 tons52,500 Btu/h · Ducted3.09115%9.020.011.260,000CEE 25CEE 26CEE AdvXcelDOEES CC199217443918
4RP15AY48AJ2NRUUDwith ducted air handler AE*L+CM59A4J+TDRRheem3.5 tons43,000 Btu/h · Ducted3.08128%7.815.211.756,500CEE 25CEE 26XcelES CC815216438507
55A6H4060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S8X1D120M5PSCTrane4.5 tons52,000 Btu/h · Ducted3.0869%7.514.311.036,000None393217147816
65TWR5060A1TRANEwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted3.0670%8.115.511.735,000Xcel651216952883
7RP15AY60AJ2NRUUDwith indoor coil D(A,C,E)60D4J+TDR and furnace R801V1005A21UHNRheem4.5 tons53,000 Btu/h · Ducted3.05115%7.815.211.764,000Xcel446217015517
85A6H5060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted3.0570%8.115.411.736,600Xcel643217149553
9XH548E2S11CHAMPION HEATING AND COOLINGwith indoor coil D(A,C,E)48D4K+TDR and furnace Z8ET080C16LMPS1York4 tons45,500 Btu/h · Ducted3.0470%7.815.212.032,000CEE 25CEE 26Xcel4,709217200422
10HH860E2S12COLEMANwith indoor coil D(A,C,E)61B4K+TDR and furnace Z8ES130D20LMPS1York4 tons50,000 Btu/h · Ducted3.0372%7.517.511.036,200CEE 25CEE 26XcelES CC11,233218774462

Ducted, 3.5 to 4.5 tons board

Ducted, 5 tons and up: ranked by COP at 5°F only

Ducted, 5 tons and up: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1AUWR-6024PHISENSE · Hi-PRO HDwith ducted air handler AUH-6024Also listed as AOH-60U3T24PHisense5 tons57,000 Btu/h · Ducted2.4674%9.019.011.042,000CEE 25CEE 26XcelES CC17214855379
2KUMXB601ALG · KUMXB601ALG5 tons60,000 Btu/h · Ducted2.3382%9.518.511.752,500CEE 25CEE 26Xcel3215402344
37HP14F60P-**ABreeze33 · 7HP14F Serieswith ducted air handler 7AH1AE60PX-Breeze335 tons57,000 Btu/h · Ducted2.2654%7.514.311.730,200None22215747906
4BH714S60P-**ABLUERIDGE · BH714S Serieswith ducted air handler BAH7E60PT-BlueRidge5 tons57,000 Btu/h · Ducted2.2654%7.514.311.730,200None26216371908
5ML14KP1-060-233A**LENNOX · MERIT ML14KP1 Serieswith ducted air handler CBK45UHET-060-230-Also sold as Ducane BHB714S60P-**A; also listed as ML14KP1-060-463ALennox5 tons57,000 Btu/h · Ducted2.2654%7.514.311.730,200None117217321300
6BMS500-AAS060-1CSXLDBOSCH · BMS Serieswith ducted air handler BMS500-AAU060-1AHDXDBosch5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 261215223315
737MBRAQ58AA3CARRIERwith ducted air handler 45MBDAQ58XH3Also sold as Midea 37MBRAQ58AA3, Midea D5CLRAH58AAK, MDV MOE30-60HFN10-M2, Arcoaire D5CLRAH58AAKCarrier5 tons58,000 Btu/h · Ducted2.2067%9.817.010.040,000CEE 25CEE 2612215323857
8MO1BU-H60B-2AMIDEAwith ducted air handler MDHHS-H60B-2AAlso sold as CTMorley MOU-B60L-2; also listed as MOE30-60HFN10-M2PMidea5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 263215471421
9MOS60H2BM0AINNOVAIRwith ducted air handler MDH60H2MHWAInnovair5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 262215725466
10BMS60UYCBLUERIDGEwith ducted air handler BMS60HCDAlso listed as BXL1A60SC0BlueRidge5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 262215853955

Ducted, 5 tons and up board

Download CSV of these COP at 5°F boardsEvery board above in one file, ranked by value within each peer group.

Typical COP at 5°F by size and duct type

The median model of each peer group. The spread between groups is why models are only compared within their own.
COP at 5°F by size and duct typeEvery model, one row per peer group; the highlighted row is the one on this board · Low-GWP (R-454B, R-32)
  • All models of the group (shape)
  • Median and middle 50% / 80%
  • Leaderboard models
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsmedian

Source: AHRI Directory · as of

Median COP at 5°F of the representative certification, per peer group
Peer groupModelsMedian COP@5°F
Ducted, up to 1.5 tons1,9821.90
Ducted, 2 tons1,2212.00
Ducted, 2.5 to 3 tons2,3532.00
Ducted, 3.5 to 4.5 tons2,7242.00
Ducted, 5 tons and up4752.00
Non-ducted, up to 1.5 tons4,1741.94
Non-ducted, 2 tons1,0452.00
Non-ducted, 2.5 to 3 tons1,2672.00
Non-ducted, 3.5 to 4.5 tons6062.00
Non-ducted, 5 tons and up892.05

    Send feedback