Skip to content

Ranked by COP at 5°F only: ducted systems, by size

Heating efficiency at 5°F outdoor temperature: units of heat delivered per unit of electricity. This board ranks by that one rating; it is not the overall cold-climate verdict, which is the cold-climate board. Inside one size and duct type the raw ratings are comparable, so these boards rank by the rating itself, more than one model per manufacturer when they earn it. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

New to heat pump ratings? The Simple view explains them in plain words →

LeaderboardsData as of updated · sources

Ducted, up to 1.5 tons: ranked by COP at 5°F only

Ducted, up to 1.5 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
137MUHAQ18AA3CARRIERwith indoor coil D(A,C,E)31A3J+TDR and furnace 58SU*B080M21**20Carrier1.5 tons17,200 Btu/h · Ducted3.3083%9.514.811.016,700CEE 25CEE 26CEE AdvXcelDOEES CC1,618218330915
2HH824E2S11YORKwith indoor coil D(A,C,E)37E2J+TDR and furnace Y82E080B12LMPS1York1.5 tons20,600 Btu/h · Ducted3.2080%9.518.811.718,300CEE 25CEE 26CEE AdvXcelDOEES CC5,553217220152
337MUHAQ18AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier1.5 tons18,000 Btu/h · Ducted3.1883%8.516.011.015,600CEE 25CEE 26XcelES CC1,446218330891
4KUSXB181ALGwith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons16,800 Btu/h · Ducted3.1765%8.115.211.712,900CEE 25CEE 26XcelES CC61217198647
5RP15AY24AJ2NRUUDwith ducted air handler AEN+CM24C2J+TDRRheem1.5 tons20,600 Btu/h · Ducted3.05127%7.514.811.227,400Xcel229218694591
6KUSXA181ALGwith ducted air handler D(A,C,E)25C3D+TDRLG1.5 tons16,900 Btu/h · Ducted3.0165%8.115.211.213,000CEE 25CEE 26XcelES CC47217198610
7SUZ-AA09NL***Mitsubishi Electric · M serieswith ducted air handler PEAD-AA09NLMitsubishi Electric1 ton9,000 Btu/h · Ducted3.0052%11.518.813.26,200CEE 25CEE 26Xcel11215734895
85TWV0X24A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCBTrane1.5 tons19,800 Btu/h · Ducted2.99122%10.021.211.727,000CEE 25CEE 26CEE AdvXcelDOEES CC185216794262
9KUSXB241ALGwith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons20,400 Btu/h · Ducted2.9567%8.515.211.716,000CEE 25CEE 26XcelES CC74217198651
105A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRPTrane1.5 tons19,500 Btu/h · Ducted2.9398%10.021.011.221,800CEE 25CEE 26XcelES CC167217117128

Ducted, up to 1.5 tons board

Ducted, 2 tons: ranked by COP at 5°F only

Ducted, 2 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1UPC24CN23STG1GUARDIANwith ducted air handler JHE24B5AC2SS1York2 tons24,000 Btu/h · Ducted3.5581%9.518.011.724,200CEE 25CEE 26XcelES CC32216409634
2KUSXA301ALGwith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons21,400 Btu/h · Ducted3.4361%8.515.211.715,900CEE 25CEE 26XcelES CC62217198620
337MURAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons23,400 Btu/h · Ducted3.1687%8.514.39.021,200CEE 25CEE 26XcelES CC3,210218331338
4NS18H24HA5***GE Applianceswith ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons22,400 Btu/h · Ducted3.1382%8.515.911.519,500CEE 25CEE 26CEE AdvXcelDOEES CC1,278217596950
537MUHAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons22,000 Btu/h · Ducted3.0698%8.515.59.820,800CEE 25CEE 26XcelES CC4,673218331062
6KUSXB301ALGwith ducted air handler D(A,C,E)31D3D+TDRLG2 tons26,000 Btu/h · Ducted3.0067%8.114.89.820,000CEE 25CEE 26XcelES CC88217198655
7248TAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17Carrier2 tons23,000 Btu/h · Ducted2.9051%8.117.513.012,900CEE 25CEE 261,712217676875
8D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRAlso listed as D5CURAH24AAKCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.09.819,500CEE 25CEE 26XcelES CC5,091217906665
95A6H7024A1AMERICAN STANDARDwith ducted air handler CM24D3J+TDRTrane2 tons21,000 Btu/h · Ducted2.87111%8.115.511.724,400CEE 25CEE 26XcelES CC731217155223
105TWR7024A1TRANEwith ducted air handler CM36B4J+TDRTrane2 tons21,600 Btu/h · Ducted2.85111%8.116.012.024,400CEE 25CEE 26XcelES CC552217754352

Ducted, 2 tons board

Ducted, 2.5–3 tons: ranked by COP at 5°F only

Ducted, 2.5–3 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
17HP14F30P-**ACONCORDwith indoor coil D(A,C,E)37A3K+TDR and furnace 97G2UH110CE20Lennox2.5 tons27,400 Btu/h · Ducted4.0662%7.515.513.016,000CEE 25CEE 261,995218807830
2NS21H36MA5-**AGEwith indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances2.5 tons31,400 Btu/h · Ducted4.0093%10.019.011.230,400CEE 25CEE 26XcelES CC143218792658
35TWR4036A1TRANEwith indoor coil DH60T4J and furnace *UHMC100CCV4Trane2.5 tons32,800 Btu/h · Ducted3.2076%7.814.812.020,400None1,629216952325
45A6H5036A1AMERICAN STANDARDwith indoor coil DH36T4J and furnace S9V2C100U5PSCTrane3 tons33,600 Btu/h · Ducted3.1970%9.016.312.022,200CEE 25CEE 26Xcel1,625217149038
55A6H4036A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace *UHMC100CCV4Trane2.5 tons32,800 Btu/h · Ducted3.1872%7.514.311.722,000None1,445217147162
6KUSXA422ALGwith ducted air handler D(A,C,E)42B4D+TDRLG3 tons37,600 Btu/h · Ducted3.1664%8.516.011.728,600CEE 25CEE 26XcelES CC35217198634
7KUSXB421ALGwith ducted air handler D(A,C,E)48D3D+TDRLG3 tons38,500 Btu/h · Ducted3.1167%8.515.211.728,800CEE 25CEE 26XcelES CC30217198667
8HH836E2S12COLEMANwith indoor coil D(A,C,E)37E3K+TDR and furnace Z8ET100C20LMPS1York2.5 tons32,000 Btu/h · Ducted3.1068%9.017.511.722,200CEE 25CEE 26XcelES CC4,692218772624
95TWR5036A1TRANEwith indoor coil DH60T4J and furnace S8V2B080M4PCBTrane3 tons33,200 Btu/h · Ducted3.0870%8.516.012.521,200CEE 25CEE 26Xcel2,223216952729
10HH836E2S11YORKwith indoor coil D(A,C,E)36B4K+TDR and furnace Y81E080C20LMPS1York3 tons33,200 Btu/h · Ducted3.0890%8.519.011.029,400CEE 25CEE 26CEE AdvXcelDOEES CC8,200217027554

Ducted, 2.5–3 tons board

Ducted, 3.5–4.5 tons: ranked by COP at 5°F only

Ducted, 3.5–4.5 tons: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1KUSXA482ALGwith ducted air handler D(A,C,E)49C3D+TDRLG3.5 tons42,500 Btu/h · Ducted3.1765%9.016.011.732,600CEE 25CEE 26XcelES CC41217198644
25TWR4060A1TRANEwith indoor coil DH60T4J and furnace S8X1D120M5PSCTrane4.5 tons52,000 Btu/h · Ducted3.0970%7.514.811.034,400None416216953201
3SL22KLV-060-230A**LENNOXwith indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60CLennox4.5 tons52,500 Btu/h · Ducted3.09115%9.020.011.260,000CEE 25CEE 26CEE AdvXcelDOEES CC199217443918
4RP15AY48AJ2NRUUDwith ducted air handler AE*L+CM59A4J+TDRRheem3.5 tons43,000 Btu/h · Ducted3.08128%7.815.211.756,500CEE 25CEE 26XcelES CC813216438507
55A6H4060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace S8X1D120M5PSCTrane4.5 tons52,000 Btu/h · Ducted3.0869%7.514.311.036,000None393217147816
65TWR5060A1TRANEwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted3.0670%8.115.511.735,000Xcel642216952883
7RP15AY60AJ2NRUUDwith indoor coil D(A,C,E)60D4J+TDR and furnace R801V1005A21UHNRheem4.5 tons53,000 Btu/h · Ducted3.05115%7.815.211.764,000Xcel411217015517
85A6H5060A1AMERICAN STANDARDwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted3.0570%8.115.411.736,600Xcel643217149553
9XH548E2S11CHAMPION HEATING AND COOLINGwith indoor coil D(A,C,E)48D4K+TDR and furnace Z8ET080C16LMPS1York4 tons45,500 Btu/h · Ducted3.0470%7.815.212.032,000CEE 25CEE 26Xcel4,601217200422
10HH860E2S12COLEMANwith indoor coil D(A,C,E)61B4K+TDR and furnace Z8ES130D20LMPS1York4 tons50,000 Btu/h · Ducted3.0372%7.517.511.036,200CEE 25CEE 26XcelES CC5,640218774462

Ducted, 3.5–4.5 tons board

Ducted, 5 tons and up: ranked by COP at 5°F only

Ducted, 5 tons and up: ranked by COP at 5°F. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1AUWR-6024PHISENSE · Hi-PRO HDwith ducted air handler AUH-6024Also listed as AOH-60U3T24PHisense5 tons57,000 Btu/h · Ducted2.4674%9.019.011.042,000CEE 25CEE 26XcelES CC17214855379
2KUMXB601ALG · KUMXB601ALG5 tons60,000 Btu/h · Ducted2.3382%9.518.511.752,500CEE 25CEE 26Xcel3215402344
37HP14F60P-**ABreeze33 · 7HP14F Serieswith ducted air handler 7AH1AE60PX-Breeze335 tons57,000 Btu/h · Ducted2.2654%7.514.311.730,200None22215747906
4BH714S60P-**ABLUERIDGE · BH714S Serieswith ducted air handler BAH7E60PT-BlueRidge5 tons57,000 Btu/h · Ducted2.2654%7.514.311.730,200None22216371908
5ML14KP1-060-233A**LENNOX · MERIT ML14KP1 Serieswith ducted air handler CBK45UHET-060-230-Also sold as Ducane BHB714S60P-**A; also listed as ML14KP1-060-463ALennox5 tons57,000 Btu/h · Ducted2.2654%7.514.311.730,200None117217321300
6BMS500-AAS060-1CSXLDBOSCH · BMS Serieswith ducted air handler BMS500-AAU060-1AHDXDBosch5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 261215223315
737MBRAQ58AA3CARRIERwith ducted air handler 45MBDAQ58XH3Also sold as Midea D5CLRAH58AAK, MDV MOE30-60HFN10-M2, Arcoaire D5CLRAH58AAKCarrier5 tons58,000 Btu/h · Ducted2.2067%9.817.010.040,000CEE 25CEE 2612215323857
837MBRAQ58AA3MIDEAwith ducted air handler 45MBDAQ58XH3Midea5 tons58,000 Btu/h · Ducted2.2067%9.817.010.040,000CEE 25CEE 263215324101
9MO1BU-H60B-2AMIDEAwith ducted air handler MDHHS-H60B-2AAlso sold as CTMorley MOU-B60L-2; also listed as MOE30-60HFN10-M2PMidea5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 263215471421
10MOS60H2BM0AINNOVAIRwith ducted air handler MDH60H2MHWAInnovair5 tons58,000 Btu/h · Ducted2.2067%9.717.010.040,000CEE 25CEE 262215725466

Ducted, 5 tons and up board

Download CSV of these COP at 5°F boardsEvery board above in one file, ranked by value within each peer group.

Typical COP at 5°F by size and duct type

The median model of each peer group. The spread between groups is why models are only compared within their own.
COP at 5°F by size and duct typeEvery model, one row per peer group; the highlighted row is the one on this board · Low-GWP (R-454B, R-32)
  • All models of the group (shape)
  • Median and middle 50% / 80%
  • Leaderboard models
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsmedian

Source: AHRI Directory · as of

Median COP at 5°F of the representative certification, per peer group
Peer groupModelsMedian COP@5°F
Ducted, up to 1.5 tons1,8271.90
Ducted, 2 tons1,1522.00
Ducted, 2.5–3 tons2,1982.00
Ducted, 3.5–4.5 tons2,6072.00
Ducted, 5 tons and up4582.00
Non-ducted, up to 1.5 tons3,5681.95
Non-ducted, 2 tons9032.00
Non-ducted, 2.5–3 tons1,1402.00
Non-ducted, 3.5–4.5 tons5702.00
Non-ducted, 5 tons and up852.05