Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.1%
Qualifying models
7,036
Qualifying certifications
221,680
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%92% of rated models reach 45% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF212,304 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0381
8.0 to under 8.3723
8.3 to under 8.5178
8.5 to under 8.81,451
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,371
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons62.1% · 2,928 of 4,715
2 tons67.6% · 1,181 of 1,748
2.5–3 tons57.3% · 1,560 of 2,724
3.5–4.5 tons45.5% · 1,222 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.5%2,089 / 6,056
Non-ducted69%2,820 / 4,087
Ducted and non-ducted97.2%2,127 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree580 of 71780.9%
Midea412 of 54675.5%
Carrier328 of 81640.2%
Daikin150 of 39438.1%
Lennox147 of 33743.6%
BlueRidge145 of 19275.5%
Trane140 of 36338.6%
TCL134 of 17775.7%
Hisense129 of 16180.1%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 141 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
35011H18HN2DA**Hotpoint · Hotpointwith ductless indoor unit HW18HN2DAHotpoint1.5 tons18,000 Btu/h · Non-ducted1.8070%9.518.0CEE 25CEE 26XcelES CC1213879381
35021H24HN2DA**Hotpoint · Hotpointwith ductless indoor unit HW24HN2DAHotpoint2 tons24,000 Btu/h · Non-ducted1.8070%9.518.0CEE 25CEE 26XcelES CC1213879382
3503KOBOGWH30ATEXH/OHouse Kobo · Charmowith ductless indoor unit KOBOGWH30ATEXH/IHouse Kobo2.5 tons30,000 Btu/h · Non-ducted1.8077%9.022.0CEE 25CEE 26XcelES CC1217897688
3504KOBOGWH36ATEXH/OHouse Kobo · Charmowith ductless indoor unit KOBOGWH36ATEXH/IHouse Kobo3 tons33,600 Btu/h · Non-ducted1.8072%8.521.0CEE 25CEE 26XcelES CC1217897690
3505ZOC-18HIN4-M-SE18iCongowith ducted air handler ZVMQFA-18HIN4L-M-SE15iCongo1.5 tons18,000 Btu/h · Ducted1.9084%8.415.0CEE 25CEE 26Xcel3217902692
3506ZOC-24HIN4-M-SE18HiCongowith ducted air handler ZVMXFA-24HI1N4-C-M-SE18iCongo2 tons23,000 Btu/h · Ducted1.82100%10.117.3CEE 25CEE 26Xcel1218647966
3507ZOD-30HIN4-M-SE18iCongowith ducted air handler ZVMXFB-30HI1N4-C-M-SE18iCongo2.5 tons30,000 Btu/h · Ducted1.9055%8.517.0CEE 25CEE 264217022539
3508ZOD-36HIN4-M-SE18HiCongowith ducted air handler ZVMXFB-36HI1N4-C-M-SE18iCongo3 tons36,000 Btu/h · Ducted1.80115%10.117.1CEE 25CEE 26Xcel1218647967
3509ZODA-48HIN4-M-SE18H*iCongowith ducted air handler ZVMXFC-48HI1N4-C-M-SE18iCongo4 tons48,000 Btu/h · Ducted1.8596%9.317.1CEE 25CEE 26Xcel1218673039
3510ZOT6P-24HIN4-M-SE20iCongowith ducted air handler ZVMXFB-24HI1N4-M-SE20iCongo2 tons24,000 Btu/h · Ducted2.3088%8.519.7CEE 25CEE 26Xcel2217902688
3511ZOT6P-36HIN4-M-SE20iCongowith ducted air handler ZVMXFB-36HI1N4-M-SE20iCongo3 tons36,000 Btu/h · Ducted2.0064%8.119.3CEE 25CEE 262217902689
3512ZWDA-24HI1N4-M-SE18iCongoiCongo2 tons24,000 Btu/h · Ducted1.94103%9.519.0CEE 25CEE 26Xcel1217022533
3513ZWDA-24HI1N4-M-SE18*iCongoiCongo2 tons24,000 Btu/h · Ducted1.94103%9.519.0CEE 25CEE 26Xcel1218814633
3514ZWDA-48HI1N4-M-SE18iCongoiCongo4 tons48,000 Btu/h · Ducted1.8093%9.019.0CEE 25CEE 26Xcel1217022535
3515ZWDA-48HI1N4-M-SE18*iCongoiCongo4 tons48,000 Btu/h · Ducted1.8093%9.019.0CEE 25CEE 26Xcel1218814635
3516ZWDA-60HI1N4-M-SE18iCongoiCongo4.5 tons55,000 Btu/h · Ducted1.8281%9.018.5CEE 25CEE 26Xcel1217022536
3517ZWDA-60HI1N4-M-SE18*iCongoiCongo4.5 tons55,000 Btu/h · Ducted1.8281%8.818.5CEE 25CEE 26Xcel1218814636
3518ZWDB-48HI1N4S4-M-SE18iCongoiCongo4 tons48,000 Btu/h · Ducted1.8093%9.019.0CEE 25CEE 26Xcel1218467237
3519ZWDB-60HI1N4S4-M-SE18iCongoiCongo4.5 tons55,000 Btu/h · Ducted1.8281%8.818.5CEE 25CEE 26Xcel1218467238
3520F09SAH20BQCiFFALCON · Savein 20Swith ductless indoor unit F09SAH20BQEiFFALCON1 ton9,000 Btu/h · Non-ducted1.8080%9.520.0CEE 25CEE 26XcelES CC1218743751
3521F09SAH21XQCiFFALCON · Savein 20Swith ductless indoor unit F09SAH21XQEiFFALCON1 ton9,000 Btu/h · Non-ducted1.8080%9.521.0CEE 25CEE 26XcelES CC1218743753
3522F09SBH23BQCiFFALCON · BreezeIN R32 23Swith ductless indoor unit F09SBH23BQEiFFALCON1 ton9,000 Btu/h · Non-ducted1.8089%10.023.0CEE 25CEE 26XcelES CC1218451107
3523F09SBH23XQCiFFALCON · BreezeIN R32 23Swith ductless indoor unit F09SBH23XQEiFFALCON1 ton9,000 Btu/h · Non-ducted1.8089%9.523.0CEE 25CEE 26XcelES CC1218451109
3524F12SBH23BQCiFFALCON · BreezeIN R32 23Swith ductless indoor unit F12SBH23BQEiFFALCON1 ton12,000 Btu/h · Non-ducted1.8083%10.024.0CEE 25CEE 26XcelES CC1218451108
3525F12SBH24XQCiFFALCON · BreezeIN R32 23Swith ductless indoor unit F12SBH24XQEiFFALCON1 ton12,000 Btu/h · Non-ducted1.8083%10.024.0CEE 25CEE 26XcelES CC1218451110

Explore qualifying models by COP at 5°F