Both views use the same certified data. This device remembers your choice.
CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.2%
- Qualifying models
- 7,790
- Qualifying certifications
- 238,391
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons61.8% · 3,352 of 5,427
- 2 tons67.4% · 1,308 of 1,941
- 2.5 to 3 tons57.3% · 1,685 of 2,942
- 3.5 to 4.5 tons45.6% · 1,293 of 2,834
- 5 tons and up32% · 152 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 61.8% · 3,352 of 5,427 |
| 2 tons | 67.4% · 1,308 of 1,941 |
| 2.5 to 3 tons | 57.3% · 1,685 of 2,942 |
| 3.5 to 4.5 tons | 45.6% · 1,293 of 2,834 |
| 5 tons and up | 32% · 152 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.7% | 2,236 / 6,438 |
| Non-ducted | 67.9% | 3,299 / 4,861 |
| Ducted and non-ducted | 97.2% | 2,255 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 593 of 729 | 81.3% |
| Midea | 418 of 555 | 75.3% |
| Carrier | 354 of 846 | 41.8% |
| Daikin | 162 of 410 | 39.5% |
| Lennox | 147 of 341 | 43.1% |
| BlueRidge | 146 of 194 | 75.3% |
| TCL | 144 of 192 | 75% |
| Trane | 143 of 370 | 38.6% |
| Hisense | 134 of 168 | 79.8% |
| York | 130 of 239 | 54.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 4376EL21KLV-036-230A**LENNOX · Elite EL21KLV Serieswith indoor coil CK40HT-30B-**+TDR and furnace ML180UH070V48B | Lennox | 3 tons33,800 Btu/h · Ducted | 2.48 | 73% | 9.0 | 18.5 | CEE 25CEE 26XcelES CC | 1,064 | 217443282 |
| 4377EL21KLV-048-230A**LENNOX · Elite EL21KLV Serieswith ducted air handler CBK45UHET-060-230- | Lennox | 4 tons47,000 Btu/h · Ducted | 2.20 | 79% | 9.0 | 19.5 | CEE 25CEE 26XcelES CC | 570 | 217121640 |
| 4378EL21KLV-060-230A**LENNOX · Elite EL21KLV Serieswith indoor coil CK40[C,U]T-60C-**+TDR and furnace SL280UH090V60C | Lennox | 4.5 tons55,000 Btu/h · Ducted | 2.18 | 65% | 8.5 | 20.5 | CEE 25CEE 26XcelES CC | 344 | 217117024 |
| 4379HP19V24S1AComfort-Airewith ducted air handler AH19X24S1A | Lennox | 2 tons24,000 Btu/h · Ducted | 1.80 | 75% | 9.0 | 18.0 | CEE 25CEE 26Xcel | 1 | 217604099 |
| 4380HP19V24S1A-CYComfort-Airewith ducted air handler AH19X24S1A-CY | Lennox | 2 tons24,000 Btu/h · Ducted | 1.80 | 75% | 9.0 | 18.0 | CEE 25CEE 26Xcel | 1 | 217604103 |
| 4381HP19V36S1AComfort-Airewith ducted air handler AH19X36S1A | Lennox | 2 tons24,000 Btu/h · Ducted | 1.90 | 83% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 217604100 |
| 4382HP19V36S1A-CYComfort-Airewith ducted air handler AH19X36S1A-CY | Lennox | 2 tons24,000 Btu/h · Ducted | 1.90 | 83% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 217604104 |
| 4383HSA1424S1-**ACOMFORT-AIREwith indoor coil D(A,C,E)24B4J+TDR and furnace GDD80C090B4MP | Lennox | 2 tons21,600 Btu/h · Ducted | 2.69 | 63% | 8.1 | 15.2 | CEE 25CEE 26 | 123 | 218447787 |
| 4384HSA1936V1-**ACOMFORT-AIRE · HSA19 Serieswith indoor coil 7ED48CX-**+TDR and furnace GDD92C090C4MP | Lennox | 3 tons34,800 Btu/h · Ducted | 2.20 | 48% | 8.5 | 16.0 | CEE 25CEE 26Xcel | 150 | 217504735 |
| 4385HSA1960V1-**ACOMFORT-AIRE · HSA19 Serieswith ducted air handler HMA60VX1*- | Lennox | 4.5 tons54,500 Btu/h · Ducted | 2.20 | 56% | 8.5 | 16.5 | CEE 25CEE 26 | 89 | 217504594 |
| 4386LI012HO-210P332LENNOXwith ductless indoor unit LI012HI-210P332 | Lennox | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 78% | 8.5 | 21.5 | CEE 25CEE 26Xcel | 1 | 216623852 |
| 4387LI012HO-210V332LENNOXwith ductless indoor unit LI012HI-210V332 | Lennox | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 71% | 8.5 | 21.5 | CEE 25CEE 26Xcel | 1 | 216623851 |
| 4388LI018HO-210P332LENNOXwith ductless indoor unit LI018HI-210P332 | Lennox | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 70% | 8.5 | 21.5 | CEE 25CEE 26Xcel | 1 | 216623853 |
| 4389LI024HO-210P332LENNOXwith ductless indoor unit LI024HI-210P332 | Lennox | 2 tons22,000 Btu/h · Non-ducted | 1.95 | 64% | 9.5 | 22.0 | CEE 25CEE 26 | 1 | 216623854 |
| 4390LI036HO-210P332LENNOXwith ductless indoor unit LI036HI-210P332 | Lennox | 3 tons33,600 Btu/h · Non-ducted | 1.80 | 72% | 8.5 | 21.0 | CEE 25CEE 26Xcel | 1 | 216623855 |
| 4391LISH036202U332LENNOX · All MATCHwith ductless indoor unit LIUH036202U332 | Lennox | 3 tons33,600 Btu/h · Non-ducted | 1.80 | 65% | 8.5 | 21.0 | CEE 25CEE 26 | 1 | 218806393 |
| 4392ML14KP1-024-230A**LENNOXwith indoor coil D(A,C,E)24B4J+TDR and furnace ML180UH030V36A | Lennox | 2 tons22,600 Btu/h · Ducted | 2.64 | 64% | 7.8 | 15.5 | CEE 25CEE 26 | 1,105 | 217334490 |
| 4393ML14KP1-036-230A**LENNOXwith ducted air handler AE*S+DM36B4J+TDR | Lennox | 3 tons33,400 Btu/h · Ducted | 2.24 | 54% | 7.5 | 14.3 | CEE 25CEE 26 | 633 | 217229808 |
| 4394ML15KSPV-018-230A**LENNOX · Merit ML15KSPV SERIESwith ducted air handler CBK43UHET-018-DV- | Lennox | 1.5 tons18,600 Btu/h · Ducted | 2.00 | 74% | 8.8 | 16.1 | CEE 25CEE 26XcelES CC | 236 | 218616017 |
| 4395ML15KSPV-030-230A**LENNOX · Merit ML15KSPV SERIESwith ducted air handler CBK43UHET-036-DV | Lennox | 2.5 tons29,600 Btu/h · Ducted | 2.20 | 65% | 9.2 | 16.4 | CEE 25CEE 26Xcel | 491 | 218616039 |
| 4396ML15KSPV-036-230A**LENNOX · Merit ML15KSPV SERIESwith ducted air handler CBK47UHET-042-230- | Lennox | 3 tons36,000 Btu/h · Ducted | 2.30 | 62% | 8.6 | 16.2 | CEE 25 | 770 | 218616047 |
| 4397ML15KSPV-042-230A**LENNOX · Merit ML15KSPV SERIESwith ducted air handler CBK47UHET-042-230- | Lennox | 3.5 tons42,500 Btu/h · Ducted | 2.20 | 63% | 9.0 | 17.1 | CEE 25 | 396 | 218616055 |
| 4398ML15KSPV-048-230A**LENNOX · Merit ML15KSPV SERIESwith ducted air handler CBK45UHET-060-230- | Lennox | 4 tons47,000 Btu/h · Ducted | 2.30 | 64% | 9.4 | 17.3 | CEE 25 | 463 | 218616062 |
| 4399ML16KP2-024-230A**LENNOX · Merit ML16KP2 SERIESwith ducted air handler CBK47UHET-030-230- | Lennox | 2 tons24,000 Btu/h · Ducted | 2.14 | 47% | 8.2 | 16.5 | CEE 25CEE 26 | 219 | 218457548 |
| 4400ML16KP2-036-230A**LENNOX · Merit ML16KP2 SERIESwith indoor coil CK40DT-50/60C-**+TDR and furnace ML180DF110E60C | Lennox | 3 tons36,000 Btu/h · Ducted | 2.10 | 51% | 8.5 | 16.5 | CEE 25CEE 26 | 475 | 218457660 |