Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.1%
Qualifying models
7,036
Qualifying certifications
221,680
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%92% of rated models reach 45% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF212,304 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0381
8.0 to under 8.3723
8.3 to under 8.5178
8.5 to under 8.81,451
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,371
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons62.1% · 2,928 of 4,715
2 tons67.6% · 1,181 of 1,748
2.5–3 tons57.3% · 1,560 of 2,724
3.5–4.5 tons45.5% · 1,222 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.5%2,089 / 6,056
Non-ducted69%2,820 / 4,087
Ducted and non-ducted97.2%2,127 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree580 of 71780.9%
Midea412 of 54675.5%
Carrier328 of 81640.2%
Daikin150 of 39438.1%
Lennox147 of 33743.6%
BlueRidge145 of 19275.5%
Trane140 of 36338.6%
TCL134 of 17775.7%
Hisense129 of 16180.1%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 232 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
5776VUH24-VA6BA(O)SAMYOU · VSHPwith ducted air handler VUH24-VA6BA(I)SAMYOU2 tons24,000 Btu/h · Ducted1.9695%11.021.0CEE 25CEE 26XcelES CC1218597510
5777VUH36-VA6BA(O)SAMYOU · VSHPwith ducted air handler VUH36-VA6BA(I)SAMYOU3 tons34,200 Btu/h · Ducted2.1073%10.220.2CEE 25CEE 26XcelES CC1217447526
5778VUH48-VA6BA(O)SAMYOU · VSHPwith ducted air handler VUH48-VA6BA(I)SAMYOU4 tons48,000 Btu/h · Ducted2.1093%11.020.0CEE 25CEE 26XcelES CC1218597509
5779VUH60-VA6BA(0)SAMYOU · VSHPwith ducted air handler VUH60-VA6BA(I)SAMYOU4.5 tons52,500 Btu/h · Ducted2.1682%10.819.6CEE 25CEE 26XcelES CC1218361278
5780STR-H121S/US1ASatoriwith ductless indoor unit STR-H121S/US1ASatori1 ton12,000 Btu/h · Non-ducted2.1072%10.023.0CEE 25CEE 26Xcel1217120283
5781STR-H182S/US1ASatoriwith ductless indoor unit STR-H182S/US1ASatori1.5 tons18,000 Btu/h · Non-ducted1.8072%10.023.0CEE 25CEE 26Xcel1217120284
5782STR-H242S/US1ASatoriwith ductless indoor unit STR-H242S/US1ASatori2 tons23,000 Btu/h · Non-ducted1.8074%9.523.0CEE 25CEE 26Xcel1217120285
578318H521ZOMISEA BREEZE · 18H Serieswith ductless indoor unit 18H521ZIMISEA BREEZE1.5 tons18,000 Btu/h · Non-ducted1.9961%9.120.2CEE 25CEE 261216014095
57849H521YOMISEA BREEZE · 9H Serieswith ductless indoor unit 9H521YIMISEA BREEZE1 ton9,000 Btu/h · Non-ducted1.9570%9.021.5CEE 25CEE 26XcelES CC1216014093
5785CSZ36H525ZMOSEA BREEZE+ · CSZ Sseieswith ductless indoor unit FC36H525ZMISEA BREEZE+3 tons36,400 Btu/h · Non-ducted2.02104%10.820.0CEE 25CEE 26XcelES CC2216014140
5786CSZ48H525ZMOSEA BREEZE+ · CSZ Sseieswith ductless indoor unit CA48H525ZMISEA BREEZE+4 tons48,000 Btu/h · Non-ducted1.9690%11.018.0CEE 25CEE 26XcelES CC2216014141
5787HMZ18H525ZMOSEA BREEZE+ · HMZ SeriesSEA BREEZE+1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.0CEE 25CEE 26XcelES CC3216014159
5788HMZ27H525ZMOSEA BREEZE+ · HMZ SeriesSEA BREEZE+2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.0CEE 25CEE 26XcelES CC3216014162
5789HMZ36H525ZMOSEA BREEZE+ · HMZ SeriesSEA BREEZE+3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.0CEE 25CEE 26XcelES CC3216014165
5790HMZ48H525ZMOSEA BREEZE+ · HMZ SeriesSEA BREEZE+4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.0CEE 25CEE 26XcelES CC3216014168
5791HMZ55H525ZMOSEA BREEZE+ · HMZ SeriesSEA BREEZE+4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1087%10.720.0CEE 25CEE 26XcelES CC3216014172
5792HSZ09H525ZMOSEA BREEZE+ · HS serieswith ducted air handler D09H525ZMISEA BREEZE+1 ton9,000 Btu/h · Ducted and non-ducted1.85120%13.820.5CEE 25CEE 26XcelES CC5216014123
5793HSZ12H525ZMOSEA BREEZE+ · HS serieswith ductless indoor unit CA12H525ZMISEA BREEZE+1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.2CEE 25CEE 26XcelES CC5216014125
5794HSZ18H525ZMOSEA BREEZE+ · HSZ Serieswith ducted air handler AH18H525ZMISEA BREEZE+1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.018.0CEE 25CEE 26XcelES CC7216014178
5795HSZ24H525ZMOSEA BREEZE+ · HS serieswith ductless indoor unit WM24H525ZMISEA BREEZE+2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.0CEE 25CEE 26XcelES CC5216014135
5796MZ18H525ZMOSEA BREEZE+ · MZ SeriesSEA BREEZE+1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC3216014146
5797MZ27H525ZMOSEA BREEZE+ · MZ SeriesSEA BREEZE+2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.0CEE 25CEE 26XcelES CC3216014147
5798MZ36H525ZMOSEA BREEZE+ · MZ SeriesSEA BREEZE+3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.0CEE 25CEE 26XcelES CC3216014150
5799MZ48H525ZMOSEA BREEZE+ · MZ SeriesSEA BREEZE+4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.4CEE 25CEE 26XcelES CC3216014154
5800MZ60H525ZMOSEA BREEZE+SEA BREEZE+5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2065%9.522.0CEE 25CEE 263216014156

Explore qualifying models by COP at 5°F