Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.2%
Qualifying models
7,790
Qualifying certifications
238,391
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%93% of rated models reach 45% (the lowest path) on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.076% of rated models reach 8 (the lowest path) on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.170% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.5At least 84% of rated models reach 9.8 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons61.8% · 3,352 of 5,427
2 tons67.4% · 1,308 of 1,941
2.5 to 3 tons57.3% · 1,685 of 2,942
3.5 to 4.5 tons45.6% · 1,293 of 2,834
5 tons and up32% · 152 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.7%2,236 / 6,438
Non-ducted67.9%3,299 / 4,861
Ducted and non-ducted97.2%2,255 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree593 of 72981.3%
Midea418 of 55575.3%
Carrier354 of 84641.8%
Daikin162 of 41039.5%
Lennox147 of 34143.1%
BlueRidge146 of 19475.3%
TCL144 of 19275%
Trane143 of 37038.6%
Hisense134 of 16879.8%
York130 of 23954.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 269 of 312
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
6701H55FMHD6XPCTCL · Apex Multi Match SeriesTCL4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9776%9.522.5CEE 25CEE 26XcelES CC3218374505
6702H60SDH20XQCTCL · Apex XS Series Unitary HPwith ducted air handler H60APH20UDETCL4.5 tons54,000 Btu/h · Ducted1.8593%9.517.0CEE 25CEE 26XcelES CC1218453821
6703TH09SVH23BWCTCL · VoxINwith ductless indoor unit TH09SVH23BWETCL1 ton9,000 Btu/h · Non-ducted1.8089%9.823.0CEE 25CEE 26XcelES CC1217626253
6704TH12SVH23BWCTCL · VoxINwith ductless indoor unit TH12SVH23BWETCL1 ton12,000 Btu/h · Non-ducted1.8083%9.823.0CEE 25CEE 26XcelES CC1217626254
6705TH12SVH23XWCTCL · VoxINwith ductless indoor unit TH12SVH23XWETCL1 ton12,000 Btu/h · Non-ducted1.8083%9.823.0CEE 25CEE 26XcelES CC1217626255
6706TH18SVH22XWCTCL · VoxINwith ductless indoor unit TH18SVH22XWETCL1.5 tons18,000 Btu/h · Non-ducted1.8083%9.522.0CEE 25CEE 26XcelES CC1217626256
6707TH24SVH21XWCTCL · VoxINwith ductless indoor unit TH24SVH21XWETCL2 tons23,000 Btu/h · Non-ducted2.1073%9.522.0CEE 25CEE 26XcelES CC1217626257
6708THH18TEI2NAG0F24TCL · Front returnwith ducted air handler THH18IEI2NAG0F24TCL1.5 tons18,000 Btu/h · Ducted1.90100%9.517.0CEE 25CEE 26XcelES CC1218083091
6709THH24HDI2NAJ0H26TCL · R32 AHU Side discharge Hyper Heatwith ducted air handler THH24IDI2NAJ0H26TCL2 tons24,000 Btu/h · Ducted1.85100%10.019.0CEE 25CEE 26XcelES CC1218467218
6710THH24HES2NAGOH24TCL · THH2with indoor coil 5TXCB003AS3 and furnace S9V2B040U3VSBTCL2 tons21,000 Btu/h · Ducted1.8086%8.116.0CEE 25CEE 26XcelES CC139217138415
6711THH24TDI2NAF2H26TCL · R32 AHU Side discharge Hyper Heatwith ducted air handler THH24IDI2NAJ0H26TCL2 tons24,000 Btu/h · Ducted1.8571%8.519.0CEE 25CEE 26XcelES CC2218467222
6712THH24TEI2NAG0F24TCL · Front returnwith ducted air handler THH24IEI2NAG0F24TCL2 tons24,000 Btu/h · Ducted1.90100%9.517.0CEE 25CEE 26XcelES CC1218082876
6713THH24TEI2NAI0H24TCL · AHUD24with ducted air handler THH24IEI2NAI0H24TCL2 tons24,000 Btu/h · Ducted1.8075%9.018.0CEE 25CEE 26XcelES CC1216706225
6714THH30TEI2NAG0F24TCL · Front returnwith ducted air handler THH30IEI2NAG0F24TCL2.5 tons30,000 Btu/h · Ducted1.90100%9.517.0CEE 25CEE 26XcelES CC1218082877
6715THH36HDI2NAJ0H26TCL · R32 AHU Side discharge Hyper Heatwith ducted air handler THH36IDI2NAJ0H26TCL3 tons36,000 Btu/h · Ducted1.85100%9.518.0CEE 25CEE 26XcelES CC1218467219
6716THH36HES2NAGOH24TCL · THH2with indoor coil 5TXCB006AS3 and furnace S9V2B040U3VSBTCL3 tons33,000 Btu/h · Ducted1.8086%8.116.0CEE 25CEE 26XcelES CC143217138426
6717THH36TEI2NAG0F24TCL · Front returnwith ducted air handler THH36IEI2NAG0F24TCL3 tons36,000 Btu/h · Ducted1.80100%9.517.0CEE 25CEE 26XcelES CC1218083092
6718THH36TEI2NAI0D24TCL · AHUD24with ducted air handler THH36IEI2NAI0H24TCL3 tons34,000 Btu/h · Ducted1.9076%9.019.0CEE 25CEE 26XcelES CC2215867859
6719THH48HDI2NAJ0H26TCL · R32 AHU Side discharge Hyper Heatwith ducted air handler THH48IDI2NAJ0H26TCL4 tons48,000 Btu/h · Ducted1.85100%9.518.0CEE 25CEE 26XcelES CC1218467220
6720THH48HES2NAGOH24TCL · THH2with indoor coil 5TXCB006AS3 and furnace S9V2B080D4VSBTCL3.5 tons41,000 Btu/h · Ducted1.8080%8.115.2CEE 25CEE 26XcelES CC135217138435
6721THH55HDI2NAJ0H26TCL · R32 AHU Side discharge Hyper Heatwith ducted air handler THH55IDI2NAJ0H26TCL4.5 tons54,000 Btu/h · Ducted1.8593%9.517.0CEE 25CEE 26XcelES CC1218467221
6722TMH18HDI2NAO0U*TCL · free matcht 24S R32TCL1.5 tons18,000 Btu/h · Non-ducted2.0078%10.025.0CEE 25CEE 26XcelES CC1218471023
6723TMH18HDI2NAO0U25TCL · free matcht 24S R32TCL1.5 tons20,000 Btu/h · Ducted and non-ducted2.0070%9.523.0CEE 25CEE 26XcelES CC2218034144
6724TMH18HDI2NAO0U25*TCL · free matcht 24S R32TCL1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0078%10.025.0CEE 25CEE 26XcelES CC3218035807
6725TMH18HEI2NAO0U24TCL · TUM24TCL1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0080%10.524.0CEE 25CEE 26XcelES CC3215351193

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter