Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.2%
Qualifying models
7,790
Qualifying certifications
238,391
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%93% of rated models reach 45% (the lowest path) on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.076% of rated models reach 8 (the lowest path) on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.170% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.5At least 84% of rated models reach 9.8 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons61.8% · 3,352 of 5,427
2 tons67.4% · 1,308 of 1,941
2.5 to 3 tons57.3% · 1,685 of 2,942
3.5 to 4.5 tons45.6% · 1,293 of 2,834
5 tons and up32% · 152 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.7%2,236 / 6,438
Non-ducted67.9%3,299 / 4,861
Ducted and non-ducted97.2%2,255 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree593 of 72981.3%
Midea418 of 55575.3%
Carrier354 of 84641.8%
Daikin162 of 41039.5%
Lennox147 of 34143.1%
BlueRidge146 of 19475.3%
TCL144 of 19275%
Trane143 of 37038.6%
Hisense134 of 16879.8%
York130 of 23954.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 303 of 312
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
7551XH648E2S11COLEMANwith indoor coil D(A,C,E)60A4K+TDR and furnace Z9ES120D20SMPS1York3.5 tons44,500 Btu/h · Ducted2.9172%8.116.0CEE 25CEE 26Xcel3,189218448057
7552XH660E2S11COLEMANwith ducted air handler DM59A4K+JMC20D2SN1+TDRYork4.5 tons51,000 Btu/h · Ducted2.8665%8.216.0CEE 25CEE 261,535218026324
7553XH936E2C11COLEMAN · LX SERIESwith ducted air handler JHC36B5AD2SS1+CCYork3 tons35,000 Btu/h · Ducted2.0093%9.019.0CEE 25CEE 26XcelES CC823218026877
7554XH960E2C11COLEMAN · LX SERIESwith ducted air handler JHC48D5CG2SS1+CCYork4 tons48,000 Btu/h · Ducted2.0095%8.521.0CEE 25CEE 26XcelES CC829218026835
7555YD524E2D11YORK · YD5with ducted air handler JDE24E5XX2DS1York2 tons24,000 Btu/h · Ducted1.8472%8.518.0CEE 25CEE 26XcelES CC6218450367
7556YD536E2D11YORK · YD5with ducted air handler JDE36E5XX2DS1York3 tons34,200 Btu/h · Ducted1.9065%8.517.0CEE 25CEE 26XcelES CC12218619077
7557YD560E2D11YORK · YD5with indoor coil CDM48C5XXS1 and furnace Y82E080C16LMPS1York3.5 tons43,000 Btu/h · Ducted1.9072%8.516.0CEE 25CEE 26XcelES CC16218787951
7558YDC36E2D11YORK · YDCwith ducted air handler JDU36F5XX2DS1York3 tons36,400 Btu/h · Ducted2.10100%10.019.0CEE 25CEE 26CEE AdvXcelDOEES CC7218619070
7559YDC60E2D11YORK · YDCwith ducted air handler JDU48F5XX2DS1York4 tons48,500 Btu/h · Ducted2.10100%10.019.0CEE 25CEE 26CEE AdvXcelDOEES CC7218450357
7560YDV36E2D11YORK · YDVwith ducted air handler JDE24E5XX2DS1York2 tons24,000 Btu/h · Ducted2.0173%9.520.0CEE 25CEE 26XcelES CC10218450360
7561YDV60E2D11YORK · YDVwith ducted air handler JDE48F5XX2DS1York4 tons47,000 Btu/h · Ducted2.0070%9.518.5CEE 25CEE 26XcelES CC7218450361
7562YH524E2S11YORKwith ducted air handler L(E,F)W30CJYork2 tons23,600 Btu/h · Ducted2.3762%7.815.2CEE 25CEE 26256216436783
7563YH536E2S11YORKwith ducted air handler L(E,G)M36EKYork2.5 tons32,600 Btu/h · Ducted2.8665%7.514.5CEE 25CEE 26803218805067
7564YH548E2S11YORKwith ducted air handler L(E,G)M60AKYork4 tons46,000 Btu/h · Ducted2.7963%7.815.2CEE 25CEE 261,139218805070
7565YH560E2S11YORKwith ducted air handler L(E,G)M60CKYork4 tons49,500 Btu/h · Ducted2.7069%7.514.8CEE 25CEE 26401218805071
7566YH618E2S11YORK · LX SERIESwith ducted air handler CTF30B5ACS1+JME12B2SN1York1.5 tons17,000 Btu/h · Ducted2.3453%8.016.0CEE 25CEE 26502218416881
7567YH624E2S11YORKwith indoor coil CH36A3K+TDR and furnace Y81E100B12LMPS1York2 tons21,600 Btu/h · Ducted2.5963%7.815.5CEE 25CEE 26459217284406
7568YH630E2S11YORKwith ducted air handler A(E,F)W36J+TDRYork2.5 tons27,800 Btu/h · Ducted2.4463%7.515.2CEE 25CEE 26192218640167
7569YH636E2S11YORKwith ducted air handler A(E,F)M36J+TDRYork2.5 tons32,200 Btu/h · Ducted2.8366%8.016.0CEE 25CEE 26701217752631
7570YH648E2S11YORKwith ducted air handler D(A,C,E)60D3J+TDRYork3.5 tons44,500 Btu/h · Ducted2.9075%8.114.3CEE 25CEE 26Xcel720217455200
7571YH660E2S11YORKwith ducted air handler D(A,C,E)60D3J+TDRYork4.5 tons51,000 Btu/h · Ducted2.8368%8.114.3CEE 25CEE 26446217455239
7572YH936E2C11YORK · LX SERIESwith ducted air handler JHC36B5AD2SS1+CCYork3 tons35,000 Btu/h · Ducted2.0093%9.019.0CEE 25CEE 26XcelES CC278218026602
7573YH960E2C11YORK · LX SERIESwith ducted air handler JHC48D5CG2SS1+CCYork4 tons48,000 Btu/h · Ducted2.0095%8.521.0CEE 25CEE 26XcelES CC264218026601
7574YHKF12YJ6DXUO-XYORKwith ductless indoor unit YHKF12XJ6DXU-RXYork1 ton12,000 Btu/h · Non-ducted2.1567%10.021.0CEE 25CEE 261216740987
7575YHKF12YJMEXVO-XYORKwith ductless indoor unit YHKF12XJMEXV-RXYork1 ton12,000 Btu/h · Non-ducted2.3278%10.123.0CEE 25CEE 26Xcel1216720983

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter