Both views use the same certified data. This device remembers your choice.
CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.2%
- Qualifying models
- 7,790
- Qualifying certifications
- 238,391
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons61.8% · 3,352 of 5,427
- 2 tons67.4% · 1,308 of 1,941
- 2.5 to 3 tons57.3% · 1,685 of 2,942
- 3.5 to 4.5 tons45.6% · 1,293 of 2,834
- 5 tons and up32% · 152 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 61.8% · 3,352 of 5,427 |
| 2 tons | 67.4% · 1,308 of 1,941 |
| 2.5 to 3 tons | 57.3% · 1,685 of 2,942 |
| 3.5 to 4.5 tons | 45.6% · 1,293 of 2,834 |
| 5 tons and up | 32% · 152 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.7% | 2,236 / 6,438 |
| Non-ducted | 67.9% | 3,299 / 4,861 |
| Ducted and non-ducted | 97.2% | 2,255 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 593 of 729 | 81.3% |
| Midea | 418 of 555 | 75.3% |
| Carrier | 354 of 846 | 41.8% |
| Daikin | 162 of 410 | 39.5% |
| Lennox | 147 of 341 | 43.1% |
| BlueRidge | 146 of 194 | 75.3% |
| TCL | 144 of 192 | 75% |
| Trane | 143 of 370 | 38.6% |
| Hisense | 134 of 168 | 79.8% |
| York | 130 of 239 | 54.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 976BMS500-AAS036-1CSXLDBOSCH · BMS Serieswith ductless indoor unit BMS500-AAU036-1AHCXD | Bosch | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.3 | 20.0 | CEE 25XcelES CC | 2 | 215223311 |
| 977BMS500-AAS048-1CSXLDBOSCH · BMS Serieswith ductless indoor unit BMS500-AAU048-1AHCXD | Bosch | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.0 | CEE 25CEE 26XcelES CC | 2 | 215223313 |
| 978BMS500-AAS060-1CSXLDBOSCH · BMS Serieswith ducted air handler BMS500-AAU060-1AHDXD | Bosch | 5 tons58,000 Btu/h · Ducted | 2.20 | 67% | 9.7 | 17.0 | CEE 25CEE 26 | 1 | 215223315 |
| 979BOHA-24MTB-M18SBOSCHwith ducted air handler AE*S+CM24C3K+TDR | Bosch | 1.5 tons20,600 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.73 | 80% | 8.1 | 17.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 31 | 218362610 |
| 980BOHA-24RTB-M18SBOSCHwith ducted air handler AE*S+CM24C3K+TDR | Bosch | 1.5 tons20,600 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.67 | 80% | 8.1 | 16.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 28 | 218362611 |
| 981BOHA-36MTB-M18SBOSCHwith indoor coil D(A,C,E)37D3J+TDR and furnace BGH97M080B3A | Bosch | 2.5 tons31,600 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.61 | 90% | 7.8 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 44 | 218362622 |
| 982BOHA-36RTB-M18SBOSCHwith indoor coil D(A,C,E)37D3J+TDR and furnace BGH97M080B3A | Bosch | 2.5 tons31,600 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.53 | 90% | 8.1 | 16.0 | CEE 25CEE 26XcelES CC | 44 | 218362623 |
| 983BOHA-60MTB-M18SBOSCHwith ducted air handler AE*L+DM59A4Z+TXV+TDR | Bosch | 3.5 tons43,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.77 | 82% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 49 | 218693498 |
| 984BOHA-60RTB-M18SBOSCHwith ducted air handler AE*L+DM60B4Z+TXV+TDR | Bosch | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.64 | 73% | 8.1 | 15.5 | CEE 25CEE 26XcelES CC | 52 | 218693503 |
| 985BOVA-24RXB-M15SBOSCHwith ducted air handler AE*S+DM24B3Z+TXV+TDR | Bosch | 2 tons21,600 Btu/h · Ducted | 2.39 | 89% | 8.1 | 17.5 | CEE 25CEE 26XcelES CC | 60 | 218693519 |
| 986BOVA-36RTB-M20SBOSCHwith ducted air handler L(E,G)M24FJ | Bosch | 2 tons21,400 Btu/h · Ducted | 2.69 | 93% | 8.1 | 18.0 | CEE 25CEE 26XcelES CC | 319 | 217887950 |
| 987BOVA-36RXB-M15SBOSCHwith ducted air handler DP37D3Z+TXV+TDR | Bosch | 2.5 tons31,400 Btu/h · Ducted | 2.40 | 67% | 7.8 | 14.3 | CEE 25CEE 26XcelES CC | 216 | 217958209 |
| 988BOVA-60MTB-M19EBOSCHwith ducted air handler AE*L+DM60B4Z+TXV+TDR | Bosch | 4 tons49,000 Btu/h · Ducted | 2.47 | 120% | 9.5 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 193 | 218693518 |
| 989BOVA-60RTB-M20SBOSCHwith ducted air handler AE*L+DM60B4Z+TXV+TDR | Bosch | 4 tons47,500 Btu/h · Ducted | 2.50 | 91% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 248 | 218693514 |
| 990BOVA-60RXB-M15SBOSCHwith indoor coil DP49D3Z+TXV+TDR and furnace BGH96M080B3C | Bosch | 3.5 tons40,500 Btu/h · Ducted | 2.44 | 75% | 7.8 | 16.0 | CEE 25CEE 26XcelES CC | 268 | 217958361 |
| 991BOVB-24RTB-M15SBOSCH · IDS Light-LGWPwith ducted air handler BIVB-24RCB-M20X | Bosch | 2 tons24,000 Btu/h · Ducted | 1.84 | 72% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 41 | 217895354 |
| 992BOVB-36MTB-M19EBOSCH · IDS Ultrawith ducted air handler BIVB-36MCB-M19X | Bosch | 3 tons36,400 Btu/h · Ducted | 2.10 | 100% | 10.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 76 | 217903121 |
| 993BOVB-36RTB-M15SBOSCH · IDS Light-LGWPwith ducted air handler BIWA-36RXB-M16X | Bosch | 3 tons33,600 Btu/h · Ducted | 1.90 | 65% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 67 | 217895630 |
| 994BOVB-36RTB-M20SBOSCH · IDS Premium LGWPwith ducted air handler BIVB-24RCB-M20X | Bosch | 2 tons24,000 Btu/h · Ducted | 2.01 | 73% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 87 | 217895327 |
| 995BOVB-60MTB-M19EBOSCH · IDS Ultrawith ducted air handler BIVB-48MCB-M19X | Bosch | 4 tons48,500 Btu/h · Ducted | 2.10 | 100% | 10.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 44 | 217895311 |
| 996BOVB-60RTB-M15SBOSCH · IDS Light-LGWPwith indoor coil BMAC4860CBTA and furnace BGH96M100C5C | Bosch | 4.5 tons53,000 Btu/h · Ducted | 1.94 | 66% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 61 | 217895617 |
| 997BOVB-60RTB-M20SBOSCHwith ducted air handler AFM47J+TDR | Bosch | 3.5 tons42,000 Btu/h · Ducted | 2.39 | 98% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 50 | 219136851 |
| 998BPBA-36RCB-M18SBOSCH · IDP Premium LGWP | Bosch | 3 tons34,200 Btu/h · Ducted | 1.80 | 64% | 8.1 | 18.0 | CEE 25CEE 26 | 1 | 216011942 |
| 999BPBA-60RCB-M18SBOSCH · IDP Premium LGWP | Bosch | 5 tons57,000 Btu/h · Ducted | 1.85 | 70% | 9.0 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 216011943 |
| 1000BPBB-36RTB-M18SBOSCH · IDP Premium LGWP | Bosch | 3 tons34,200 Btu/h · Ducted | 1.80 | 64% | 8.1 | 18.0 | CEE 25CEE 26 | 1 | 217895358 |