Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.1%
- Qualifying models
- 7,036
- Qualifying certifications
- 221,680
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,238 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 519 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,401 |
| 75 to under 80% | 1,156 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 720 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,111 |
| 7.8 to under 8.0 | 381 |
| 8.0 to under 8.3 | 723 |
| 8.3 to under 8.5 | 178 |
| 8.5 to under 8.8 | 1,451 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,500 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,371 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,002 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,101 |
| 15.5 to under 16.0 | 284 |
| 16.0 to under 16.5 | 624 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 849 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 680 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 917 |
| 20.5 to under 21.0 | 162 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 18 |
| 27.0 to under 27.5 | 60 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 95 |
| 8.5 to under 9.0 | 214 |
| 9.0 to under 9.5 | 702 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 881 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,678 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,869 |
| 12.5 to under 13.0 | 951 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 274 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 179 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons62.1% · 2,928 of 4,715
- 2 tons67.6% · 1,181 of 1,748
- 2.5–3 tons57.3% · 1,560 of 2,724
- 3.5–4.5 tons45.5% · 1,222 of 2,687
- 5 tons and up31.7% · 145 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 62.1% · 2,928 of 4,715 |
| 2 tons | 67.6% · 1,181 of 1,748 |
| 2.5–3 tons | 57.3% · 1,560 of 2,724 |
| 3.5–4.5 tons | 45.5% · 1,222 of 2,687 |
| 5 tons and up | 31.7% · 145 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.5% | 2,089 / 6,056 |
| Non-ducted | 69% | 2,820 / 4,087 |
| Ducted and non-ducted | 97.2% | 2,127 / 2,189 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 580 of 717 | 80.9% |
| Midea | 412 of 546 | 75.5% |
| Carrier | 328 of 816 | 40.2% |
| Daikin | 150 of 394 | 38.1% |
| Lennox | 147 of 337 | 43.6% |
| BlueRidge | 145 of 192 | 75.5% |
| Trane | 140 of 363 | 38.6% |
| TCL | 134 of 177 | 75.7% |
| Hisense | 129 of 161 | 80.1% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1101290VAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)30C3J+TDR and furnace 88*TB66135C24 | Carrier | 2 tons21,800 Btu/h · Ducted | 2.79 | 83% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 738 | 217676739 |
| 1102290VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 3 tons35,400 Btu/h · Ducted | 2.04 | 72% | 9.5 | 19.5 | CEE 25CEE 26XcelES CC | 1,240 | 215670617 |
| 1103290VAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CP49D3J+TDR and furnace 88*TB36070C14 | Carrier | 3.5 tons43,000 Btu/h · Ducted | 2.70 | 87% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 884 | 217676989 |
| 1104290VAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)60C3J+TDR and furnace 83*CB60100C21 | Carrier | 4.5 tons51,000 Btu/h · Ducted | 2.38 | 87% | 8.1 | 18.0 | CEE 25CEE 26XcelES CC | 385 | 217676854 |
| 1105291VAN054**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 21 VS Cold Climate Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 88*TB48090C17 | Carrier | 4 tons47,000 Btu/h · Ducted | 2.08 | 98% | 10.5 | 18.5 | CEE 25CEE 26XcelES CC | 469 | 215588078 |
| 1106293VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 83*CB36040C17 | Carrier | 2 tons23,200 Btu/h · Ducted | 2.10 | 81% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 437 | 217624600 |
| 1107293VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 3 tons35,000 Btu/h · Ducted | 2.10 | 75% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 944 | 215933965 |
| 1108293VAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)48C3J+TDR and furnace 88*TB66135C24 | Carrier | 3.5 tons41,500 Btu/h · Ducted | 2.68 | 81% | 9.5 | 21.5 | CEE 25CEE 26XcelES CC | 748 | 217676882 |
| 1109293VAN060**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 5 tons58,000 Btu/h · Ducted | 2.18 | 74% | 9.0 | 20.0 | CEE 25CEE 26XcelES CC | 311 | 215931487 |
| 111037MAHAQ06AA3CARRIER · 45M Serieswith ducted air handler 45MBDAQ06XA3 | Carrier | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 13 | 215323798 |
| 111137MAHAQ09AA3CARRIER · 45M Serieswith ducted air handler 45MBDAQ12XA3 | Carrier | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.89 | 112% | 12.5 | 21.5 | CEE 25CEE 26XcelES CC | 25 | 215323802 |
| 111237MAHAQ12AA3CARRIER · 45M Serieswith ductless indoor unit 45MCCAQ12XA3 | Carrier | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 92% | 10.2 | 23.0 | CEE 25CEE 26XcelES CC | 25 | 215323804 |
| 111337MAHAQ18AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ18XB3 | Carrier | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.20 | 92% | 10.1 | 18.2 | CEE 25CEE 26XcelES CC | 33 | 215318764 |
| 111437MAHAQ24AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ24XA3 | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.34 | 83% | 13.5 | 21.2 | CEE 25CEE 26XcelES CC | 21 | 215323746 |
| 111537MAHAQ33AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ36XB3 | Carrier | 3 tons33,000 Btu/h · Ducted and non-ducted | 2.00 | 97% | 10.0 | 16.7 | CEE 25CEE 26XcelES CC | 9 | 215318766 |
| 111637MARAQ09AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ09XA3 | Carrier | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.37 | 80% | 12.5 | 26.0 | CEE 25CEE 26XcelES CC | 25 | 215323749 |
| 111737MARAQ12AA1CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ12XA1 | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.33 | 64% | 9.5 | 23.5 | CEE 25CEE 26 | 5 | 215323748 |
| 111837MARAQ12AA3CARRIER · 45M Serieswith ductless indoor unit 45MBFAQ12XA3 | Carrier | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.51 | 74% | 11.0 | 24.7 | CEE 25CEE 26XcelES CC | 25 | 215323824 |
| 111937MARAQ18AA3CARRIER · 45M Serieswith ducted air handler 45MBDAQ18XH3 | Carrier | 1.5 tons17,500 Btu/h · Ducted and non-ducted | 2.41 | 71% | 11.4 | 20.0 | CEE 25CEE 26XcelES CC | 33 | 215323832 |
| 112037MARAQ24AA3CARRIER · 45M Serieswith ductless indoor unit 45MAHAQ24XA3 | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.54 | 78% | 11.7 | 23.1 | CEE 25CEE 26XcelES CC | 21 | 215323752 |
| 112137MARAQ30AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ30XB3 | Carrier | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.10 | 68% | 8.8 | 17.0 | CEE 25CEE 26 | 9 | 215413022 |
| 112237MBHAQ36AA3CARRIER · 45M Serieswith ducted air handler 45MBDAQ36XH3 | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.10 | 90% | 11.1 | 17.8 | CEE 25CEE 26XcelES CC | 16 | 215323844 |
| 112337MBHAQ48AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ48XA3 | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.00 | 92% | 10.2 | 17.0 | CEE 25CEE 26XcelES CC | 16 | 215318770 |
| 112437MBRAQ36AA3CARRIER · 45M Serieswith ductless indoor unit 45MBCAQ36XA3 | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.4 | 20.0 | CEE 25CEE 26XcelES CC | 16 | 215323850 |
| 112537MBRAQ48AA3CARRIER · 45M Serieswith ductless indoor unit 45MBCAQ48XA3 | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.1 | CEE 25CEE 26XcelES CC | 16 | 215323853 |