Both views use the same certified data. This device remembers your choice.
CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.2%
- Qualifying models
- 7,790
- Qualifying certifications
- 238,391
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons61.8% · 3,352 of 5,427
- 2 tons67.4% · 1,308 of 1,941
- 2.5 to 3 tons57.3% · 1,685 of 2,942
- 3.5 to 4.5 tons45.6% · 1,293 of 2,834
- 5 tons and up32% · 152 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 61.8% · 3,352 of 5,427 |
| 2 tons | 67.4% · 1,308 of 1,941 |
| 2.5 to 3 tons | 57.3% · 1,685 of 2,942 |
| 3.5 to 4.5 tons | 45.6% · 1,293 of 2,834 |
| 5 tons and up | 32% · 152 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.7% | 2,236 / 6,438 |
| Non-ducted | 67.9% | 3,299 / 4,861 |
| Ducted and non-ducted | 97.2% | 2,255 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 593 of 729 | 81.3% |
| Midea | 418 of 555 | 75.3% |
| Carrier | 354 of 846 | 41.8% |
| Daikin | 162 of 410 | 39.5% |
| Lennox | 147 of 341 | 43.1% |
| BlueRidge | 146 of 194 | 75.3% |
| TCL | 144 of 192 | 75% |
| Trane | 143 of 370 | 38.6% |
| Hisense | 134 of 168 | 79.8% |
| York | 130 of 239 | 54.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1176248TAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil C(A,C,D,E)48C3J+TDR and furnace 83*SB60080M21 | Carrier | 3.5 tons44,000 Btu/h · Ducted | 2.93 | 60% | 8.1 | 16.0 | CEE 25CEE 26 | 1,659 | 217677318 |
| 1177248TAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith indoor coil CP61B3J+TDR and furnace 83*SB60080M21 | Carrier | 4.5 tons51,500 Btu/h · Ducted | 2.83 | 61% | 7.8 | 16.5 | CEE 25CEE 26 | 942 | 217677703 |
| 1178249VAN024**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler FT5AN(B,X)C36L | Carrier | 2 tons23,400 Btu/h · Ducted | 2.02 | 87% | 10.0 | 18.5 | CEE 25CEE 26XcelES CC | 1,165 | 217950372 |
| 1179249VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler F55AA*B36L | Carrier | 3 tons33,600 Btu/h · Ducted | 2.18 | 77% | 9.0 | 15.2 | CEE 25CEE 26XcelES CC | 879 | 217928529 |
| 1180249VAN048**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler FT5ANBD60L | Carrier | 4 tons46,000 Btu/h · Ducted | 2.32 | 75% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 573 | 217914936 |
| 1181249VAN060**AA*BRYANT HEATING AND COOLING SYSTEMS · Preferred 19 SEER2 VS HPwith ducted air handler F55AA*D60L | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.16 | 70% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 401 | 217933355 |
| 118227SCA524A**30*CARRIERwith indoor coil C(A,C,D,E)24A3J+TDR and furnace 59TP6C100V21**20 | Carrier | 1.5 tons20,600 Btu/h · Ducted | 2.69 | 72% | 7.5 | 14.3 | CEE 25CEE 26Xcel | 2,981 | 217178131 |
| 118327SCA536A**30*CARRIERwith indoor coil C(A,C,D,E)36B3J+TDR and furnace 58SU*B080M21**20 | Carrier | 2.5 tons31,200 Btu/h · Ducted | 2.66 | 68% | 7.5 | 14.8 | CEE 25 | 2,296 | 217178214 |
| 118427SCA536A**60*CARRIER · COMFORT 15 SEER2 HPwith ducted air handler FJ5AN*C48L | Carrier | 3 tons36,800 Btu/h · Ducted | 2.20 | 48% | 8.0 | 16.0 | CEE 25 | 151 | 217033611 |
| 118527SPA624A**30*CARRIERwith ducted air handler PE(S,T)29J | Carrier | 2 tons21,000 Btu/h · Ducted | 2.64 | 65% | 7.5 | 15.2 | CEE 25CEE 26 | 2,974 | 217006647 |
| 118627SPA631A**30*CARRIER · PERFORMANCE 16 SEER2 HPwith indoor coil CAA**3721AM and furnace 58CU*B040C17**12 | Carrier | 2.5 tons29,200 Btu/h · Ducted | 2.06 | 46% | 8.0 | 15.5 | CEE 25 | 851 | 217689952 |
| 118727SPA636A**30*CARRIERwith ducted air handler PE(S,T)38J | Carrier | 2.5 tons32,400 Btu/h · Ducted | 2.61 | 60% | 7.5 | 14.3 | CEE 25 | 1,976 | 217006650 |
| 118827TPA824A**30*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CAA**3721AM and furnace 58SU*B040M17**12 | Carrier | 2 tons23,800 Btu/h · Ducted | 2.24 | 45% | 8.5 | 18.0 | CEE 25 | 1,782 | 215647843 |
| 118927TPA836A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 3 tons36,000 Btu/h · Ducted | 2.48 | 49% | 8.5 | 17.0 | CEE 25CEE 26 | 1,505 | 215628934 |
| 119027TPA848A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60L | Carrier | 4 tons48,500 Btu/h · Ducted | 2.32 | 51% | 8.1 | 18.0 | CEE 25CEE 26 | 1,252 | 215560636 |
| 119127TPA860A**30*CARRIER · 2-STAGE 18 SEER HPwith indoor coil CVAMA6124XMA and furnace 58TN*B135C24**22 | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.34 | 52% | 8.5 | 15.5 | CEE 25CEE 26 | 766 | 215626616 |
| 119227VNA024A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNXB24L*+UI | Carrier | 2 tons23,400 Btu/h · Ducted | 2.04 | 70% | 9.0 | 17.5 | CEE 25CEE 26XcelES CC | 438 | 215662625 |
| 119327VNA036A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 3 tons35,400 Btu/h · Ducted | 2.04 | 72% | 9.5 | 19.5 | CEE 25CEE 26XcelES CC | 863 | 215670616 |
| 119427VNA048A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 4 tons46,500 Btu/h · Ducted | 2.20 | 70% | 9.5 | 19.5 | CEE 25CEE 26XcelES CC | 427 | 215675343 |
| 119527VNA060A*030*CARRIER · Infinity 20 VS Heat Pumpwith indoor coil CVAMA6021XMA*+UI and furnace 58CU*B040C17**12 | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.15 | 72% | 8.1 | 18.0 | CEE 25CEE 26XcelES CC | 228 | 215682803 |
| 119627VNA154A*030*CARRIER · Infinity 21 VS Cold Climate Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 58TN*B090C17**16 | Carrier | 4 tons47,000 Btu/h · Ducted | 2.08 | 98% | 10.5 | 18.5 | CEE 25CEE 26XcelES CC | 488 | 215588077 |
| 119727VNA324A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CVAMA2517XMA*+UI and furnace 58CU*B040C17**12 | Carrier | 2 tons23,200 Btu/h · Ducted | 2.10 | 81% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 449 | 217624599 |
| 119827VNA336A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 3 tons35,000 Btu/h · Ducted | 2.10 | 75% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 640 | 215933964 |
| 119927VNA348A*030*CARRIER · Infinity 23 VS Heat Pumpwith indoor coil CAA**4821AM*+UI and furnace 58CU*A100C21**20 | Carrier | 3.5 tons43,500 Btu/h · Ducted | 2.00 | 76% | 9.5 | 20.5 | CEE 25CEE 26XcelES CC | 352 | 215933974 |
| 120027VNA360A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UI | Carrier | 5 tons58,000 Btu/h · Ducted | 2.18 | 74% | 9.0 | 20.0 | CEE 25CEE 26XcelES CC | 197 | 215931484 |