Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.1%
Qualifying models
7,036
Qualifying certifications
221,680
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%92% of rated models reach 45% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF212,304 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0381
8.0 to under 8.3723
8.3 to under 8.5178
8.5 to under 8.81,451
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,371
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons62.1% · 2,928 of 4,715
2 tons67.6% · 1,181 of 1,748
2.5–3 tons57.3% · 1,560 of 2,724
3.5–4.5 tons45.5% · 1,222 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.5%2,089 / 6,056
Non-ducted69%2,820 / 4,087
Ducted and non-ducted97.2%2,127 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree580 of 71780.9%
Midea412 of 54675.5%
Carrier328 of 81640.2%
Daikin150 of 39438.1%
Lennox147 of 33743.6%
BlueRidge145 of 19275.5%
Trane140 of 36338.6%
TCL134 of 17775.7%
Hisense129 of 16180.1%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 55 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1351T5H8T36*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *97VTN1002122ACarrier3 tons36,000 Btu/h · Ducted2.4051%8.515.0CEE 25CEE 26849216357662
1352T5H8T48*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier4 tons48,500 Btu/h · Ducted2.3451%8.118.0CEE 25CEE 26602216152755
1353T5H8T60*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith indoor coil EVM5X61M24A*+WALLCON and furnace *80CSU0802120BCarrier4.5 tons55,500 Btu/h · Ducted2.3652%8.515.5CEE 25CEE 26433216346853
1354W5H5S24*K*AAA*GRANDAIREwith ducted air handler AE*S+CM24C3J+TDRCarrier2 tons21,400 Btu/h · Ducted2.6160%7.515.2CEE 25CEE 261,256215876955
1355W5H5S31*K*AAA*GRANDAIRE · 15 SEER2 HPwith indoor coil W5A*43M21XA and furnace WFEU060B048BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.5CEE 25452217692221
1356W5H5S36*K*AAA*GRANDAIREwith ducted air handler L(E,G)M48BJCarrier3 tons33,600 Btu/h · Ducted2.4655%7.814.8CEE 25798218158210
1357W5H8T24*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D3617XCarrier2 tons24,000 Btu/h · Ducted2.1646%7.818.0CEE 25621218695386
1358W5H8T36*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler WCGL605*DCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.0CEE 25CEE 26418215628959
1359W5H8T48*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler WCGL605*DCarrier4 tons48,500 Btu/h · Ducted2.3251%8.118.0CEE 25CEE 26328215560728
1360W5H8T60*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith indoor coil W5VM61M24XA and furnace WFET110C066ACarrier4.5 tons56,000 Btu/h · Ducted2.3453%8.516.0CEE 25CEE 26199215626662
1361W5H9V18AKAAAGrandaire · W5H Serieswith ducted air handler WCVL185CBCarrier1.5 tons18,000 Btu/h · Ducted2.0095%9.719.0CEE 25CEE 26XcelES CC1218160681
1362W5H9V24AKAAAGrandaire · W5H Serieswith ducted air handler WCVL245CBCarrier2 tons23,000 Btu/h · Ducted1.8790%10.018.3CEE 25CEE 26XcelES CC8218160676
1363W5H9V30AKAAAGrandaire · W5H Serieswith ducted air handler WCVL305CBCarrier2.5 tons30,000 Btu/h · Ducted1.9696%10.016.8CEE 25CEE 26XcelES CC1218160682
1364W5H9V36AKAAAGrandaire · W5H Serieswith ducted air handler WCVL365CCCarrier3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC17218160677
1365W5H9V48AKAAAGrandaire · W5H Serieswith ducted air handler WCVL485CDCarrier4 tons48,000 Btu/h · Ducted1.9092%9.516.5CEE 25CEE 26XcelES CC11218160678
1366W5H9V60AKAAAGrandairewith ducted air handler (H,G)73L*60+TXV+TDCarrier4 tons47,000 Btu/h · Ducted1.8389%8.115.2CEE 25CEE 26XcelES CC5218695899
1367WD5CUHAH18AAK+TIC2025-0016GRANDAIREwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.0CEE 25CEE 26Xcel111217399873
1368WD5CUHAH24AAKGRANDAIREwith ducted air handler FMA5X24**ALCarrier2 tons22,600 Btu/h · Ducted2.1091%9.017.0CEE 25CEE 26Xcel250216739138
1369XH524E2S11*KENMORE · LX SERIESwith ducted air handler CTM30B5ACS1+JME12B2SN1Carrier2 tons24,000 Btu/h · Ducted2.2854%8.115.2CEE 25CEE 2678216942245
1370XH536E2S11*KENMORE · LX SERIESwith ducted air handler CTM36C5CDS1+JME16C2SN1Carrier2.5 tons32,800 Btu/h · Ducted2.4457%8.115.2CEE 25CEE 26288216941318
1371XH618E2S11KENMORE · LX SERIESwith indoor coil CTF24B5ABS2 and furnace Z8VT080B12SMPC1Carrier1.5 tons18,000 Btu/h · Ducted2.3454%8.016.0CEE 25CEE 2697218601707
1372XH624E2S11*KENMORE · LX SERIESwith ducted air handler CTF36B5ADS1+JME12B2SN1Carrier2 tons24,000 Btu/h · Ducted2.3053%8.116.0CEE 25CEE 26176217020791
1373XH630E2S11KENMORE · LX SERIESwith ducted air handler JHE30B5AD2SS2Carrier2.5 tons30,000 Btu/h · Ducted2.3653%8.016.0CEE 25CEE 2645218821625
1374XH636E2S11*KENMORE · LX SERIESwith ducted air handler CTF48D5CFS1+JMC20D2SN1Carrier3 tons36,000 Btu/h · Ducted2.5053%8.517.0CEE 25CEE 26355217738966
1375XH648E2S11*KENMORE · LX SERIESwith ducted air handler JHC60D5CH2SS1Carrier4 tons48,000 Btu/h · Ducted2.4058%8.116.0CEE 25CEE 26389217020819

Explore qualifying models by COP at 5°F