CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.2%
Qualifying models
7,790
Qualifying certifications
238,391
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%93% of rated models reach 45% (the lowest path) on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.076% of rated models reach 8 (the lowest path) on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.170% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.5At least 84% of rated models reach 9.8 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons61.8% · 3,352 of 5,427
2 tons67.4% · 1,308 of 1,941
2.5 to 3 tons57.3% · 1,685 of 2,942
3.5 to 4.5 tons45.6% · 1,293 of 2,834
5 tons and up32% · 152 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.7%2,236 / 6,438
Non-ducted67.9%3,299 / 4,861
Ducted and non-ducted97.2%2,255 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree593 of 72981.3%
Midea418 of 55575.3%
Carrier354 of 84641.8%
Daikin162 of 41039.5%
Lennox147 of 34143.1%
BlueRidge146 of 19475.3%
TCL144 of 19275%
Trane143 of 37038.6%
Hisense134 of 16879.8%
York130 of 23954.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 59 of 312
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1451T5H3V60*K*AAA*TEMPSTAR · SmartSense 23 VS HPwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716BCarrier4.5 tons56,000 Btu/h · Ducted2.1075%8.518.0CEE 25CEE 26XcelES CC180215931663
1452T5H6S24*K*AAA*TEMPSTAR · MAINLINE 16 SEER2 HPwith ducted air handler FMA5X30**ALCarrier2 tons24,000 Btu/h · Ducted2.2649%8.516.5CEE 25CEE 261,165214424130
1453T5H6S31*K*AAA*TEMPSTAR · MAINLINE 16 SEER2 HPwith indoor coil EA*5X37M21A*+WALLCON and furnace *80CSU0401712BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.5CEE 25653217717192
1454T5H8T24*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *80MSU0401712ACarrier2 tons23,800 Btu/h · Ducted2.2445%8.518.0CEE 251,060216366447
1455T5H8T36*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith indoor coil EA*5X37M21A and furnace *97VTN1002122ACarrier3 tons36,000 Btu/h · Ducted2.4051%8.515.5CEE 25CEE 26849216357662
1456T5H8T48*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith ducted air handler FTMA5B60L0DCarrier4 tons48,500 Btu/h · Ducted2.3451%8.118.0CEE 25CEE 26602216152755
1457T5H8T60*K*AAA*TEMPSTAR · Mainline 18 SEER2 HPwith indoor coil EVM5X61M24A*+WALLCON and furnace *80CSU0802120BCarrier4.5 tons55,500 Btu/h · Ducted2.3652%8.515.5CEE 25CEE 26433216346853
1458W5H5S24*K*AAA*GRANDAIREwith ducted air handler AE*S+CM24C3J+TDRCarrier2 tons21,400 Btu/h · Ducted2.6160%7.515.2CEE 25CEE 261,496215876955
1459W5H5S31*K*AAA*GRANDAIRE · 15 SEER2 HPwith indoor coil W5A*43M21XA and furnace WFEU060B048BCarrier2.5 tons29,200 Btu/h · Ducted2.0646%8.015.5CEE 25558217692221
1460W5H5S36*K*AAA*GRANDAIREwith ducted air handler L(E,G)M48BJCarrier3 tons33,600 Btu/h · Ducted2.4655%7.814.8CEE 251,077218158210
1461W5H8T24*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D3617XCarrier2 tons24,000 Btu/h · Ducted2.1646%7.818.0CEE 25763218695386
1462W5H8T36*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler WCGL605*DCarrier3 tons36,000 Btu/h · Ducted2.4849%8.517.0CEE 25CEE 26540215628959
1463W5H8T48*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith ducted air handler WCGL605*DCarrier4 tons48,500 Btu/h · Ducted2.3251%8.118.0CEE 25CEE 26424215560728
1464W5H8T60*K*AAA*GRANDAIRE · 2-STAGE 18 SEER HPwith indoor coil W5VM61M24XA and furnace WFET110C066ACarrier4.5 tons56,000 Btu/h · Ducted2.3453%8.516.0CEE 25CEE 26241215626662
1465W5H8V18AKAAAGrandaire · W5H Serieswith ducted air handler WCVL185CBCarrier1.5 tons18,000 Btu/h · Ducted2.0062%9.118.8CEE 25CEE 263218853989
1466W5H8V24AKAAAGrandaire · W5H Serieswith ducted air handler WCVL245CBCarrier2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC3218853990
1467W5H8V30AKAAAGrandairewith ducted air handler WCVL305CCCarrier2.5 tons30,000 Btu/h · Ducted2.0062%8.517.0CEE 253218853991
1468W5H8V36AKAAAGrandaire · W5H Serieswith ducted air handler WCVL365CCCarrier3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC3218853992
1469W5H8V48AKAAAGrandaire · W5H Serieswith ducted air handler WCVL605CDCarrier4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC3218853993
1470W5H9V18AKAAAGrandaire · W5H Serieswith ducted air handler W5HM24X14EACarrier1.5 tons18,000 Btu/h · Ducted2.0695%9.516.1CEE 25CEE 26XcelES CC3218853995
1471W5H9V24AKAAAGrandaire · W5H Serieswith ducted air handler WCVL245CBCarrier2 tons23,000 Btu/h · Ducted1.8790%10.018.3CEE 25CEE 26XcelES CC10218160676
1472W5H9V30AKAAAGrandaire · W5H Serieswith ducted air handler WCVL305CBCarrier2.5 tons30,000 Btu/h · Ducted1.9696%10.016.8CEE 25CEE 26XcelES CC4218160682
1473W5H9V36AKAAAGrandaire · W5H Serieswith ducted air handler WCVL365CCCarrier3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC20218160677
1474W5H9V48AKAAAGrandaire · W5H Serieswith ducted air handler WCVL485CDCarrier4 tons48,000 Btu/h · Ducted1.9092%9.516.5CEE 25CEE 26XcelES CC13218160678
1475W5H9V60AKAAAGrandaire · W5H Serieswith ducted air handler W5HM60X24EACarrier4 tons47,000 Btu/h · Ducted1.8374%8.115.2CEE 25CEE 26XcelES CC7218214197

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter