CEE 2026 Tier 1 (Split ASHP): 6,854 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
6,854
Qualifying certifications
202,824
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,222 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,351
2.00 to under 2.102,428
2.10 to under 2.201,325
2.20 to under 2.30777
2.30 to under 2.40512
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,157 rated models · median 72%87% of rated models reach 50% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,156
80 to under 85%799
85 to under 90%375
90 to under 95%720
95 to under 100%582
100 to under 105%758
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF212,307 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,112
7.8 to under 8.0381
8.0 to under 8.3724
8.3 to under 8.5177
8.5 to under 8.81,450
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,372
9.8 to under 10.0306
10.0 to under 10.31,627
10.3 to under 10.5228
10.5 to under 10.8603
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,331 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,004
14.5 to under 15.0192
15.0 to under 15.51,100
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5681
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.019
27.0 to under 27.561
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER212,327 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.594
8.5 to under 9.0214
9.0 to under 9.5703
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,679
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5275
14.5 to under 15.0114
15.0 to under 15.5180
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.9% · 2,870 of 4,716
2 tons66.2% · 1,157 of 1,748
2.5–3 tons54.6% · 1,489 of 2,726
3.5–4.5 tons44.4% · 1,193 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.6%1,974 / 6,057
Non-ducted67.7%2,768 / 4,089
Ducted and non-ducted96.5%2,112 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree572 of 71779.8%
Midea403 of 54673.8%
Carrier288 of 81635.3%
BlueRidge141 of 19273.4%
Lennox139 of 33741.2%
Daikin137 of 39434.8%
TCL134 of 17775.7%
Trane133 of 36336.6%
Mitsubishi Electric126 of 15680.8%
Hisense122 of 16175.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 104 of 275
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2576GFU24HP230V1R32AOGREE · E Serieswith ducted air handler GFU24HP230V1R32AHGree2 tons24,000 Btu/h · Ducted2.0096%10.018.0CEE 25CEE 26XcelES CC1218450826
2577GFU36HP230V1R32AOGREE · E Serieswith ducted air handler GFU24HP230V1R32AHGree2 tons24,000 Btu/h · Ducted2.0096%10.018.0CEE 25CEE 26XcelES CC4218450822
2578GFU48HP230V1R32AOGREE · E Serieswith ducted air handler GFU48HP230V1R32AHGree4 tons48,000 Btu/h · Ducted2.00100%10.019.0CEE 25CEE 26XcelES CC1218450827
2579GFU60HP230V1R32AOGREE · E Serieswith ducted air handler GFU60HP230V1R32AHGree4.5 tons53,000 Btu/h · Ducted2.10100%10.518.5CEE 25CEE 26CEE AdvXcelDOEES CC4218450825
2580GK-H02TC/NHA-D(U)GREE · DC inverter rooftop unitGree2 tons24,000 Btu/h · Ducted2.05126%8.818.0CEE 25CEE 26XcelES CC1216763049
2581GK-H03TC/NHA-D(U)GREE · DC inverter rooftop unitGree3 tons34,000 Btu/h · Ducted2.0589%8.518.0CEE 25CEE 26XcelES CC1215866830
2582GK-H04TC/NHA-D(U)GREE · DC inverter rooftop unitGree4 tons47,000 Btu/h · Ducted2.04110%8.518.0CEE 25CEE 26XcelES CC1216763053
2583GK-H05TC/NHA-D(U)GREE · DC inverter rooftop unitGree4.5 tons56,000 Btu/h · Ducted2.0491%8.318.0CEE 25CEE 26XcelES CC1215866831
2584GMV-V36WL/NHC-T(U)GREE · Ultra Heat GMV6 MiniGree3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.4070%9.823.5CEE 25CEE 26XcelES CC3217123443
2585GMV-V48WL/NHC-T(U)GREE · Ultra Heat GMV6 MiniGree4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3070%9.023.5CEE 25CEE 26XcelES CC3217123444
2586GMV-V60WL/NHC-T(U)GREE · Ultra Heat GMV6 MiniGree5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2072%9.222.5CEE 25CEE 26XcelES CC3216772249
2587GS09HP115V1AOGREE · Charmowith ductless indoor unit GS09HP115V1AIGree1 ton9,100 Btu/h · Non-ducted1.8676%8.820.5CEE 25CEE 26XcelES CC1218361219
2588GS09HP115V1CLOGREE · Cliviawith ductless indoor unit GS09HP115V1CLIGree1 ton9,100 Btu/h · Non-ducted1.8395%10.527.0CEE 25CEE 26XcelES CC1218716413
2589GS09HP115V1PUOGREE · Pularwith ductless indoor unit GS09HP115V1PUIGree1 ton9,100 Btu/h · Non-ducted1.8395%10.527.0CEE 25CEE 26XcelES CC1218425004
2590GS09HP115V1ZEOGREE · ZENOwith ductless indoor unit GS09HP115V1ZEIGree1 ton9,100 Btu/h · Non-ducted1.8070%8.618.5CEE 25CEE 26Xcel1218471541
2591GS09HP230V1ASOGREE · Charmowith ductless indoor unit GS09HP230V1ASIGree1 ton9,100 Btu/h · Non-ducted1.9476%8.820.5CEE 25CEE 26XcelES CC1218361218
2592GS09HP230V1CLOGREE · Ductedwith ducted air handler GS09HP230V1DAIGree1 ton9,100 Btu/h · Ducted and non-ducted2.1490%9.222.0CEE 25CEE 26XcelES CC6218807664
2593GS09HP230V1PUOGREE · Ductedwith ducted air handler GS09HP230V1DAIGree1 ton9,100 Btu/h · Ducted and non-ducted2.1590%9.222.0CEE 25CEE 26XcelES CC6218636377
2594GS09HP230V1RYOGREE · Airywith ductless indoor unit GS09HP230V1RYIGree1 ton9,100 Btu/h · Non-ducted2.11108%11.230.0CEE 25CEE 26CEE AdvXcelDOEES CC1218425006
2595GS09HP230V1ZEOGREE · ZENOwith ductless indoor unit GS09HP230V1ZEIGree1 ton9,100 Btu/h · Non-ducted1.8576%8.618.8CEE 25CEE 26Xcel1218471540
2596GS12HP115V1CLOGREE · Cliviawith ductless indoor unit GS12HP115V1CLIGree1 ton12,000 Btu/h · Non-ducted1.9579%9.524.5CEE 25CEE 26XcelES CC1218716416
2597GS12HP115V1PUOGREE · Cliviawith ductless indoor unit GS12HP115V1PUIGree1 ton12,000 Btu/h · Non-ducted1.9579%9.524.5CEE 25CEE 26XcelES CC1218425007
2598GS12HP230V1CLOGREE · Cliviawith ductless indoor unit GS12HP230V1CLIGree1 ton12,000 Btu/h · Ducted and non-ducted1.9592%9.524.5CEE 25CEE 26XcelES CC6218716415
2599GS12HP230V1PUOGREE · Cliviawith ductless indoor unit GS12HP230V1PUIGree1 ton12,000 Btu/h · Ducted and non-ducted1.9592%9.524.5CEE 25CEE 26XcelES CC6218425008
2600GS12HP230V1RYOGREE · Airywith ductless indoor unit GS12HP230V1RYIGree1 ton12,000 Btu/h · Non-ducted2.00100%10.029.5CEE 25CEE 26XcelES CC1218425009

Explore qualifying models by COP at 5°F