Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026 Tier 1 (Split ASHP): 6,851 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 55.6%
- Qualifying models
- 6,851
- Qualifying certifications
- 202,087
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,238 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 519 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,401 |
| 75 to under 80% | 1,156 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 720 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,111 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 722 |
| 8.3 to under 8.5 | 178 |
| 8.5 to under 8.8 | 1,451 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,501 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,370 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,002 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,102 |
| 15.5 to under 16.0 | 283 |
| 16.0 to under 16.5 | 624 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 849 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 680 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 918 |
| 20.5 to under 21.0 | 161 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 18 |
| 27.0 to under 27.5 | 60 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 95 |
| 8.5 to under 9.0 | 214 |
| 9.0 to under 9.5 | 702 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 881 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,678 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,870 |
| 12.5 to under 13.0 | 950 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 274 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 179 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.8% · 2,869 of 4,715
- 2 tons66.2% · 1,157 of 1,748
- 2.5–3 tons54.6% · 1,487 of 2,724
- 3.5–4.5 tons44.4% · 1,193 of 2,687
- 5 tons and up31.7% · 145 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.8% · 2,869 of 4,715 |
| 2 tons | 66.2% · 1,157 of 1,748 |
| 2.5–3 tons | 54.6% · 1,487 of 2,724 |
| 3.5–4.5 tons | 44.4% · 1,193 of 2,687 |
| 5 tons and up | 31.7% · 145 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.6% | 1,973 / 6,056 |
| Non-ducted | 67.7% | 2,766 / 4,087 |
| Ducted and non-ducted | 96.5% | 2,112 / 2,189 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 572 of 717 | 79.8% |
| Midea | 403 of 546 | 73.8% |
| Carrier | 288 of 816 | 35.3% |
| BlueRidge | 141 of 192 | 73.4% |
| Lennox | 139 of 337 | 41.2% |
| Daikin | 137 of 394 | 34.8% |
| TCL | 134 of 177 | 75.7% |
| Trane | 133 of 363 | 36.6% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
| Hisense | 122 of 161 | 75.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 3851ML16KP2-024-230A**LENNOX · Merit ML16KP2 SERIESwith ducted air handler CBK47UHET-030-230- | Lennox | 2 tons24,000 Btu/h · Ducted | 2.14 | 47% | 8.2 | 16.5 | CEE 25CEE 26 | 218 | 218457548 |
| 3852ML16KP2-036-230A**LENNOX · Merit ML16KP2 SERIESwith indoor coil CK40DT-50/60C-**+TDR and furnace ML180DF110E60C | Lennox | 3 tons36,000 Btu/h · Ducted | 2.10 | 51% | 8.5 | 16.5 | CEE 25CEE 26 | 475 | 218457660 |
| 3853ML16KP2-048-230A**LENNOX · Merit ML16KP2 SERIESwith indoor coil CK40[C,U]T-60D-**+TDR and furnace ML297UH135XV60D | Lennox | 4 tons46,000 Btu/h · Ducted | 2.26 | 53% | 8.5 | 16.0 | CEE 25CEE 26 | 317 | 218695120 |
| 3854MMLD009S6S-1PLENNOX · Console - Premium (CAC)with ductless indoor unit MFMD009S6-1P | Lennox | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.80 | 80% | 9.7 | 21.0 | CEE 25CEE 26XcelES CC | 5 | 216581328 |
| 3855MMLD012S6S-1PLENNOX · 1-Way Cassette (WindFree™) Premium (CAC)with ductless indoor unit M1WD012S6-1P | Lennox | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.79 | 80% | 9.5 | 21.0 | CEE 25CEE 26XcelES CC | 5 | 216581321 |
| 3856MMLD018S6S-1PLENNOX · MMLD Mini-Splitwith ductless indoor unit M1WD018S6-1P | Lennox | 1.5 tons17,500 Btu/h · Ducted and non-ducted | 1.80 | 100% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 8 | 215810023 |
| 3857MMLD020S6M-1PLENNOX · MMLD Multi-Zone | Lennox | 2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.95 | 100% | 10.5 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 216760278 |
| 3858MMLD024S6M-1PLENNOX · MMLD Multi-Zone | Lennox | 2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.85 | 100% | 10.4 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 216760277 |
| 3859MMLD024S6S-1PLENNOX · MMLD Mini-Splitwith ductless indoor unit M33D024S6-1P | Lennox | 2 tons24,000 Btu/h · Ducted and non-ducted | 1.80 | 100% | 10.2 | 22.0 | CEE 25CEE 26XcelES CC | 4 | 215810028 |
| 3860MMLD030S6M-1PLENNOX · MMLD Multi-Zone | Lennox | 2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.81 | 100% | 10.0 | 22.5 | CEE 25CEE 26XcelES CC | 3 | 216760276 |
| 3861MMLD030S6S-1PLENNOX · MMLD Mini-Splitwith ductless indoor unit M33D030S6-1P | Lennox | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 1.80 | 100% | 10.7 | 22.8 | CEE 25CEE 26XcelES CC | 4 | 215810030 |
| 3862MMLD036S6M-1PLENNOX · MMLD Multi-Zone | Lennox | 3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.04 | 100% | 9.5 | 21.5 | CEE 25CEE 26XcelES CC | 3 | 216760275 |
| 3863MMLD036S6S-1PLENNOX · MMLD Mini-Splitwith ducted air handler MDDD036S6-1P | Lennox | 3 tons36,000 Btu/h · Ducted and non-ducted | 1.80 | 100% | 9.8 | 20.0 | CEE 25CEE 26XcelES CC | 4 | 215810032 |
| 3864MMLD048S6S-1PLENNOX · MMLD Mini-Splitwith ducted air handler MDDD048S6-1P | Lennox | 4 tons47,000 Btu/h · Ducted and non-ducted | 1.80 | 100% | 9.5 | 18.0 | CEE 25CEE 26XcelES CC | 3 | 215810033 |
| 3865MMPD018S6S-1PLENNOX · MMPD Mini-Splitwith ductless indoor unit M33D018S6-1P | Lennox | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 1.80 | 80% | 9.3 | 23.8 | CEE 25CEE 26XcelES CC | 3 | 215810034 |
| 3866MMPD020S6M-1PLENNOX · MMPD Multi-Zone | Lennox | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.81 | 70% | 9.0 | 20.0 | CEE 25CEE 26Xcel | 3 | 216760266 |
| 3867MMPD024S6M-1PLENNOX · MMPD Multi-Zone | Lennox | 2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.81 | 66% | 9.5 | 22.5 | CEE 25CEE 26 | 3 | 216760265 |
| 3868MMPD024S6S-1PLENNOX · MMPD Mini-Splitwith ductless indoor unit M33D024S6-1P | Lennox | 2 tons24,000 Btu/h · Ducted and non-ducted | 1.80 | 80% | 9.6 | 21.6 | CEE 25CEE 26XcelES CC | 3 | 215810035 |
| 3869MMPD030S6S-1PLENNOX · MMPD Mini-Splitwith ductless indoor unit M33D030S6-1P | Lennox | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 1.80 | 80% | 9.5 | 21.7 | CEE 25CEE 26XcelES CC | 3 | 215810036 |
| 3870MMPD036S6M-1PLENNOX · MMPD Multi-Zone | Lennox | 2.5 tons32,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.81 | 73% | 9.5 | 22.5 | CEE 25CEE 26Xcel | 3 | 216760264 |
| 3871MMPD036S6S-1PLENNOX · MMPD Mini-Splitwith ducted air handler MDDD036S6-1P | Lennox | 3 tons36,000 Btu/h · Ducted and non-ducted | 1.80 | 80% | 8.8 | 17.4 | CEE 25CEE 26XcelES CC | 3 | 215810040 |
| 3872MMPD048S6M-1PLENNOX · MMPD Multi-Zone | Lennox | 4 tons46,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.81 | 65% | 9.0 | 21.0 | CEE 25CEE 26 | 3 | 216760263 |
| 3873MWHD009S6S-1PLENNOX · MWHD Mini-Splitwith ductless indoor unit MWHD009S6-1P | Lennox | 1 ton9,000 Btu/h · Non-ducted | 1.91 | 68% | 9.0 | 25.0 | CEE 25CEE 26 | 1 | 216411315 |
| 3874MWHD012S6S-1PLENNOX · MWHD Mini-Splitwith ductless indoor unit MWHD012S6-1P | Lennox | 1 ton12,000 Btu/h · Non-ducted | 1.76 | 67% | 9.0 | 24.0 | CEE 25CEE 26 | 1 | 216411316 |
| 3875MWHD015S6S-1PLENNOX · MWHD Mini-Splitwith ductless indoor unit MWHD015S6-1P | Lennox | 1.5 tons15,000 Btu/h · Non-ducted | 2.24 | 87% | 10.0 | 21.5 | CEE 25CEE 26Xcel | 1 | 216411317 |