CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 55.6%
- Qualifying models
- 7,576
- Qualifying certifications
- 217,907
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.3% · 3,270 of 5,427
- 2 tons65.9% · 1,279 of 1,941
- 2.5 to 3 tons54.8% · 1,612 of 2,942
- 3.5 to 4.5 tons44.6% · 1,264 of 2,834
- 5 tons and up31.8% · 151 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.3% · 3,270 of 5,427 |
| 2 tons | 65.9% · 1,279 of 1,941 |
| 2.5 to 3 tons | 54.8% · 1,612 of 2,942 |
| 3.5 to 4.5 tons | 44.6% · 1,264 of 2,834 |
| 5 tons and up | 31.8% · 151 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.8% | 2,113 / 6,438 |
| Non-ducted | 66.3% | 3,223 / 4,861 |
| Ducted and non-ducted | 96.6% | 2,240 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 412 of 555 | 74.2% |
| Carrier | 313 of 846 | 37% |
| Daikin | 145 of 410 | 35.4% |
| TCL | 144 of 192 | 75% |
| BlueRidge | 142 of 194 | 73.2% |
| Lennox | 139 of 341 | 40.8% |
| Trane | 134 of 370 | 36.2% |
| York | 130 of 239 | 54.4% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 4326KUMXA301ALG · KUMXA301A | LG | 2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.24 | 100% | 9.8 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214848477 |
| 4327KUMXA361ALG · KUMXA361A | LG | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.27 | 100% | 11.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402345 |
| 4328KUMXA421ALG · KUMXA421A | LG | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.29 | 100% | 11.0 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402347 |
| 4329KUMXA481ALG · KUMXA481A | LG | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.34 | 100% | 10.5 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215408636 |
| 4330KUMXB181ALG · KUMXB181A | LG | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.30 | 80% | 9.8 | 22.5 | CEE 25CEE 26Xcel | 3 | 214848481 |
| 4331KUMXB241ALG · KUMXB241A | LG | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.51 | 75% | 9.8 | 22.5 | CEE 25CEE 26Xcel | 3 | 214848483 |
| 4332KUMXB301ALG · KUMXB301A | LG | 2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.38 | 75% | 9.5 | 22.0 | CEE 25CEE 26Xcel | 3 | 215402335 |
| 4333KUMXB361ALG · KUMXB361A | LG | 2.5 tons32,800 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.38 | 70% | 9.5 | 21.5 | CEE 25CEE 26Xcel | 3 | 215402337 |
| 4334KUMXB481ALG · KUMXB481A | LG | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.12 | 73% | 9.5 | 20.5 | CEE 25CEE 26Xcel | 3 | 215402339 |
| 4335KUMXB541ALG · KUMXB541A | LG | 4 tons50,500 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 70% | 9.5 | 20.6 | CEE 25CEE 26Xcel | 3 | 215402341 |
| 4336KUMXB601ALG · KUMXB601A | LG | 4.5 tons56,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.34 | 82% | 10.0 | 20.5 | CEE 25CEE 26Xcel | 3 | 215402343 |
| 4337KUSAB091ALG · KUSAB091Awith ductless indoor unit KNUAB091A | LG | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 87% | 10.9 | 23.8 | CEE 25CEE 26XcelES CC | 2 | 215413005 |
| 4338KUSAB092ALG · KUSAB092Awith ductless indoor unit KNUAB092A | LG | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 87% | 10.9 | 23.8 | CEE 25CEE 26Xcel | 2 | 218861276 |
| 4339KUSAB121ALG · KUSAB121Awith ductless indoor unit KNUAB121A | LG | 1 ton12,000 Btu/h · Non-ducted | 1.99 | 74% | 10.5 | 22.5 | CEE 25CEE 26XcelES CC | 2 | 215413007 |
| 4340KUSAB122ALG · KUSAB122Awith ductless indoor unit KNUAB122A | LG | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 74% | 10.5 | 22.5 | CEE 25CEE 26Xcel | 2 | 218861278 |
| 4341KUSAB181ALG · KUSAB181Awith ductless indoor unit KNUAB181A | LG | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 70% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 2 | 215413009 |
| 4342KUSAB182ALG · KUSAB182Awith ductless indoor unit KNUAB182A | LG | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 70% | 10.0 | 23.0 | CEE 25CEE 26Xcel | 2 | 218861280 |
| 4343KUSAC091ALG · KUSAC091Awith ductless indoor unit KNSAC091A | LG | 1 ton9,000 Btu/h · Non-ducted | 1.81 | 71% | 9.2 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 214931158 |
| 4344KUSAC091BLG · KUSAC091Bwith ductless indoor unit KNSAC091B | LG | 1 ton9,000 Btu/h · Non-ducted | 1.81 | 71% | 9.2 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 214931170 |
| 4345KUSAC121ALG · KUSAC121Awith ductless indoor unit KNSAC121A | LG | 1 ton11,000 Btu/h · Non-ducted | 1.80 | 70% | 9.0 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 214931160 |
| 4346KUSAC121BLG · KUSAC121Bwith ductless indoor unit KNSAC121B | LG | 1 ton11,000 Btu/h · Non-ducted | 1.80 | 70% | 9.0 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 214931172 |
| 4347KUSAC181ALG · KUSAC181Awith ductless indoor unit KNSAC181A | LG | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 70% | 9.4 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 214931161 |
| 4348KUSAC241ALG · KUSAC241Awith ductless indoor unit KNSAC241A | LG | 2 tons21,200 Btu/h · Non-ducted | 1.80 | 63% | 8.8 | 20.0 | CEE 25CEE 26 | 1 | 214931163 |
| 4349KUSAD091ALG · KUSAD091Awith ductless indoor unit KNSAD091A | LG | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 86% | 9.2 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 217486288 |
| 4350KUSAD091BLG · KUSAD091Bwith ductless indoor unit KNSAD091B | LG | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 86% | 9.2 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 217486286 |