Both views use the same certified data. This device remembers your choice.
CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 55.6%
- Qualifying models
- 7,576
- Qualifying certifications
- 217,907
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.3% · 3,270 of 5,427
- 2 tons65.9% · 1,279 of 1,941
- 2.5 to 3 tons54.8% · 1,612 of 2,942
- 3.5 to 4.5 tons44.6% · 1,264 of 2,834
- 5 tons and up31.8% · 151 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.3% · 3,270 of 5,427 |
| 2 tons | 65.9% · 1,279 of 1,941 |
| 2.5 to 3 tons | 54.8% · 1,612 of 2,942 |
| 3.5 to 4.5 tons | 44.6% · 1,264 of 2,834 |
| 5 tons and up | 31.8% · 151 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.8% | 2,113 / 6,438 |
| Non-ducted | 66.3% | 3,223 / 4,861 |
| Ducted and non-ducted | 96.6% | 2,240 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 412 of 555 | 74.2% |
| Carrier | 313 of 846 | 37% |
| Daikin | 145 of 410 | 35.4% |
| TCL | 144 of 192 | 75% |
| BlueRidge | 142 of 194 | 73.2% |
| Lennox | 139 of 341 | 40.8% |
| Trane | 134 of 370 | 36.2% |
| York | 130 of 239 | 54.4% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 6926M6S60HN/O6S4PTRUST AIR CONDITIONERS | TRUST AIR CONDITIONERS | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 67% | 9.2 | 18.0 | CEE 25CEE 26 | 3 | 217678181 |
| 6927M6S60HS/O6S4PTRUST AIR CONDITIONERS | TRUST AIR CONDITIONERS | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 67% | 9.2 | 18.0 | CEE 25CEE 26 | 3 | 217678178 |
| 6928OAH09H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ducted air handler IUMDL09H/I63P | TRUST AIR CONDITIONERS | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.89 | 112% | 12.5 | 21.4 | CEE 25CEE 26XcelES CC | 5 | 217678077 |
| 6929OAH12H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ductless indoor unit IUMC412H/I61P | TRUST AIR CONDITIONERS | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 96% | 11.6 | 22.2 | CEE 25CEE 26XcelES CC | 6 | 217678072 |
| 6930OAH18H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ducted air handler IUMDH18H/I63P | TRUST AIR CONDITIONERS | 1.5 tons17,500 Btu/h · Ducted and non-ducted | 2.10 | 92% | 11.1 | 18.4 | CEE 25CEE 26XcelES CC | 7 | 217678082 |
| 6931OAH24H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ductless indoor unit IUMC424H/I61P | TRUST AIR CONDITIONERS | 2 tons23,400 Btu/h · Ducted and non-ducted | 2.23 | 95% | 11.6 | 20.7 | CEE 25CEE 26XcelES CC | 4 | 217678074 |
| 6932OAH30H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ductless indoor unit IUMW130H/I61P | TRUST AIR CONDITIONERS | 3 tons33,000 Btu/h · Non-ducted | 1.91 | 96% | 10.5 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 217678070 |
| 6933OAH36H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ducted air handler IUMDH36H/I63P | TRUST AIR CONDITIONERS | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.10 | 90% | 11.1 | 17.7 | CEE 25CEE 26XcelES CC | 3 | 217678084 |
| 6934OAH48H/O6S4PTRUST AIR CONDITIONERS · OAH Serieswith ducted air handler IUMDH48H/I63P | TRUST AIR CONDITIONERS | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.00 | 91% | 10.8 | 16.7 | CEE 25CEE 26XcelES CC | 3 | 217678085 |
| 6935OUS06H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMC106H/I61P | TRUST AIR CONDITIONERS | 0.5 tons6,500 Btu/h · Non-ducted | 2.40 | 109% | 12.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217678094 |
| 6936OUS09H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMW109H/I61P | TRUST AIR CONDITIONERS | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.33 | 82% | 13.0 | 24.6 | CEE 25CEE 26XcelES CC | 5 | 217678061 |
| 6937OUS12H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMCO12H/I61P | TRUST AIR CONDITIONERS | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.51 | 74% | 11.0 | 24.6 | CEE 25CEE 26XcelES CC | 6 | 217678112 |
| 6938OUS18H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ducted air handler IUMDH18H/I63P | TRUST AIR CONDITIONERS | 1.5 tons17,500 Btu/h · Ducted and non-ducted | 2.41 | 71% | 11.3 | 20.0 | CEE 25CEE 26XcelES CC | 7 | 217678109 |
| 6939OUS24H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMC424H/I61P | TRUST AIR CONDITIONERS | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.30 | 74% | 10.5 | 22.0 | CEE 25CEE 26XcelES CC | 4 | 217678101 |
| 6940OUS36H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMC436H/I61P | TRUST AIR CONDITIONERS | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.3 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217678102 |
| 6941OUS48H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMC448H/I61P | TRUST AIR CONDITIONERS | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 217678103 |
| 6942OUS60H/O6S4PTRUST AIR CONDITIONERSwith ducted air handler IUMDH60H/I63P | TRUST AIR CONDITIONERS | 5 tons58,000 Btu/h · Ducted and non-ducted | 2.20 | 67% | 9.7 | 17.0 | CEE 25CEE 26 | 2 | 217678174 |
| 6943HP12TFEXTR454BTURBOFIN · T-prowith ductless indoor unit HP12TFINTR454B | TURBOFIN | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 100% | 10.5 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218037123 |
| 6944HP18TFEXTR454BTURBOFIN · T-prowith ductless indoor unit HP18TFINTR454B | TURBOFIN | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 99% | 10.0 | 23.5 | CEE 25CEE 26XcelES CC | 1 | 218037124 |
| 6945HP18TFEXTR454B*TURBOFIN · T-prowith ductless indoor unit HP18TFINTR454B | TURBOFIN | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 99% | 10.0 | 23.5 | CEE 25CEE 26XcelES CC | 1 | 218160714 |
| 6946HP24TFEXTR454BTURBOFIN · T-prowith ductless indoor unit HP24TFINTR454B | TURBOFIN | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 93% | 10.0 | 22.5 | CEE 25CEE 26XcelES CC | 1 | 218037125 |
| 6947FM9K115-OTURBROwith ductless indoor unit FM9K115- I | TURBRO | 1 ton9,000 Btu/h · Non-ducted | 2.06 | 22% | 8.6 | 19.0 | CEE 25CEE 26Xcel | 2 | 217040575 |
| 6948GREENLAND-12K115/OTURBRO · T-Prowith ductless indoor unit GREENLAND-12K115/I | TURBRO | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217222926 |
| 6949GREENLAND-12K230/OTURBRO · T-Prowith ductless indoor unit GREENLAND-12K230/I | TURBRO | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217222927 |
| 6950GREENLAND-18K230/OTURBRO · T-Prowith ductless indoor unit GREENLAND-18K230/I | TURBRO | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217222928 |