Skip to content

CEE 2026 Tier 1 (Split ASHP): 6,849 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
6,849
Qualifying certifications
201,713
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,218 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,237
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,153 rated models · median 72%87% of rated models reach 50% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,157
80 to under 85%798
85 to under 90%375
90 to under 95%719
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF212,299 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0382
8.0 to under 8.3721
8.3 to under 8.5177
8.5 to under 8.81,449
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,370
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,323 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,102
15.5 to under 16.0283
16.0 to under 16.5623
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5915
20.5 to under 21.0161
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER212,319 rated models · median 11.6At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0213
9.0 to under 9.5700
9.5 to under 10.0831
10.0 to under 10.5880
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0950
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.6
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.9% · 2,869 of 4,712
2 tons66.2% · 1,157 of 1,747
2.5–3 tons54.6% · 1,485 of 2,722
3.5–4.5 tons44.4% · 1,193 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.6%1,975 / 6,060
Non-ducted67.8%2,765 / 4,081
Ducted and non-ducted96.5%2,109 / 2,185

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree572 of 71779.8%
Midea403 of 54673.8%
Carrier288 of 81635.3%
BlueRidge141 of 19273.4%
Lennox137 of 33141.4%
Daikin137 of 39434.8%
TCL134 of 17775.7%
Trane133 of 36336.6%
Mitsubishi Electric126 of 15680.8%
Hisense122 of 16175.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 29 of 274
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
701BMS36UYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS36CCBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.0CEE 25CEE 26XcelES CC3215853951
702BMS48HHUYCBLUERIDGE · BMS Serieswith ducted air handler BMS48HCDBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted2.0091%10.816.7CEE 25CEE 26XcelES CC3215853962
703BMS48UYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS48CCBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.0CEE 25CEE 26XcelES CC3215853952
704BMS60UYCBLUERIDGEwith ducted air handler BMS60HCDBlueRidge5 tons58,000 Btu/h · Ducted and non-ducted2.2067%9.717.0CEE 25CEE 262215853955
705BMS626HHYCBLUERIDGE · BMS Serieswith ducted air handler BMC6LCDBlueRidge0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC3215853938
706BMS635SHYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS635SHYWBlueRidge0.5 tons6,000 Btu/h · Non-ducted2.00150%15.635.0CEE 25CEE 26XcelES CC1215853907
707BMS919YCBLUERIDGE · BMS Serieswith ductless indoor unit BMS919YWBlueRidge1 ton9,000 Btu/h · Non-ducted2.1670%9.719.0CEE 25CEE 26XcelES CC1215853883
708BMS922XCBLUERIDGE · BMS Serieswith ductless indoor unit BMS922XWBlueRidge1 ton9,000 Btu/h · Non-ducted1.9570%9.021.5CEE 25CEE 26XcelES CC1215853887
709BMS922YCBLUERIDGE · BMS Serieswith ductless indoor unit BMS922YWBlueRidge1 ton9,000 Btu/h · Non-ducted1.9970%9.421.6CEE 25CEE 26XcelES CC1215853889
710BMS925XCBLUERIDGE · BMS Serieswith ductless indoor unit BMS925XWBlueRidge1 ton9,000 Btu/h · Non-ducted2.2272%10.025.4CEE 25CEE 26XcelES CC1215853895
711BMS926YCBLUERIDGE · BMS Serieswith ductless indoor unit BMC9HHYWBlueRidge1 ton9,000 Btu/h · Ducted and non-ducted2.3780%12.525.8CEE 25CEE 26XcelES CC6215853897
712BMS927HHYCBLUERIDGE · BMS Serieswith ducted air handler BMC9LCDBlueRidge1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.4CEE 25CEE 26XcelES CC6215853939
713BMS933SHYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS933SHYWBlueRidge1 ton9,000 Btu/h · Non-ducted2.00113%14.633.3CEE 25CEE 26XcelES CC1215853908
714BMSAH18HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH18IBlueRidge1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC2215853875
715BMSAH24HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH24IBlueRidge2 tons24,000 Btu/h · Ducted2.1486%10.018.6CEE 25CEE 26XcelES CC2215853876
716BMSAH30HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH30IBlueRidge2.5 tons30,000 Btu/h · Ducted1.97101%10.817.2CEE 25CEE 26XcelES CC2215853877
717BMSAH36HHCBLUERIDGE · BMS Serieswith ducted air handler BMS2AH36IBlueRidge3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC2215853872
718BMSAH48HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH48IBlueRidge4 tons48,000 Btu/h · Ducted2.00100%9.517.5CEE 25CEE 26XcelES CC2215853879
719BMSAH60HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH60IBlueRidge4.5 tons54,000 Btu/h · Ducted1.9098%9.517.5CEE 25CEE 26XcelES CC2215853880
720BMSAHS1819CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH18IBlueRidge1.5 tons18,000 Btu/h · Ducted2.0062%9.118.8CEE 25CEE 261215853863
721BMSAHS2418CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH24IBlueRidge2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC1215853864
722BMSAHS3616CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH36IBlueRidge3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC1215853866
723BMSAHS4816CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH48IBlueRidge4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC1215853867
724BNG2A18SCNBLUERIDGE · BNG Serieswith ducted air handler BNGFA18DH2BlueRidge1.5 tons18,000 Btu/h · Ducted2.0062%9.118.8CEE 25CEE 263216997498
725BNG2A24SCNBLUERIDGE · BNG Serieswith ducted air handler BNGFA24DH2BlueRidge2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC3216997499

Explore qualifying models by COP at 5°F