Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026 Tier 1 (Split ASHP): 6,849 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 55.6%
- Qualifying models
- 6,849
- Qualifying certifications
- 199,354
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,237 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 520 |
| 50 to under 55% | 565 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,400 |
| 75 to under 80% | 1,157 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 719 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,111 |
| 7.8 to under 8.0 | 383 |
| 8.0 to under 8.3 | 720 |
| 8.3 to under 8.5 | 177 |
| 8.5 to under 8.8 | 1,449 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,501 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,369 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,002 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,103 |
| 15.5 to under 16.0 | 282 |
| 16.0 to under 16.5 | 623 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 848 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 680 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 916 |
| 20.5 to under 21.0 | 160 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 18 |
| 27.0 to under 27.5 | 60 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 95 |
| 8.5 to under 9.0 | 213 |
| 9.0 to under 9.5 | 700 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 880 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,678 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,871 |
| 12.5 to under 13.0 | 948 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 274 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 179 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.6 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.9% · 2,869 of 4,712
- 2 tons66.2% · 1,157 of 1,747
- 2.5–3 tons54.6% · 1,485 of 2,722
- 3.5–4.5 tons44.4% · 1,193 of 2,687
- 5 tons and up31.7% · 145 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.9% · 2,869 of 4,712 |
| 2 tons | 66.2% · 1,157 of 1,747 |
| 2.5–3 tons | 54.6% · 1,485 of 2,722 |
| 3.5–4.5 tons | 44.4% · 1,193 of 2,687 |
| 5 tons and up | 31.7% · 145 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.6% | 1,975 / 6,060 |
| Non-ducted | 67.8% | 2,765 / 4,081 |
| Ducted and non-ducted | 96.5% | 2,109 / 2,185 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 572 of 717 | 79.8% |
| Midea | 403 of 546 | 73.8% |
| Carrier | 288 of 816 | 35.3% |
| BlueRidge | 141 of 192 | 73.4% |
| Lennox | 137 of 331 | 41.4% |
| Daikin | 137 of 394 | 34.8% |
| TCL | 134 of 177 | 75.7% |
| Trane | 133 of 363 | 36.6% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
| Hisense | 122 of 161 | 75.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 101ACIQ-24-HPDACIQwith ducted air handler CM24A2J+TDR | ACIQ | 2 tons21,200 Btu/h · Ducted | 2.86 | 78% | 8.1 | 15.2 | CEE 25CEE 26XcelES CC | 11 | 217617062 |
| 102ACIQ-24TD-HPACiQwith ducted air handler ACIQ-24TD-AH | ACIQ | 2 tons24,000 Btu/h · Ducted | 1.80 | 75% | 9.0 | 18.0 | CEE 25CEE 26Xcel | 1 | 217006581 |
| 103ACIQ-24Z-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24W-HP230C | ACIQ | 2 tons24,000 Btu/h · Non-ducted | 2.14 | 71% | 9.3 | 18.7 | CEE 25CEE 26XcelES CC | 1 | 216032330 |
| 104ACIQ-24ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24W-HH-MD | ACIQ | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.34 | 83% | 13.5 | 21.0 | CEE 25CEE 26XcelES CC | 5 | 216032337 |
| 105ACIQ-24ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24W-HH-MD | ACIQ | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.54 | 78% | 11.7 | 23.0 | CEE 25CEE 26XcelES CC | 7 | 218471560 |
| 106ACIQ-27Z-HH-M4CACIQ · ACIQ Series | ACIQ | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 216032364 |
| 107ACIQ-30-EHPDACIQwith ducted air handler DM36E3J+TDR | ACIQ | 2 tons26,400 Btu/h · Ducted | 2.24 | 62% | 7.5 | 15.2 | CEE 25CEE 26 | 14 | 217617066 |
| 108ACIQ-30-HPDACIQwith ducted air handler AE*S+CM30B3J+TDR | ACIQ | 2.5 tons27,400 Btu/h · Ducted | 2.77 | 70% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 21 | 217617040 |
| 109ACIQ-30Z-HP230CACIQ · ACIQwith ductless indoor unit ACIQ-30W-HP230C | ACIQ | 2.5 tons30,000 Btu/h · Non-ducted | 1.88 | 66% | 9.2 | 20.0 | CEE 25CEE 26 | 1 | 216032331 |
| 110ACIQ-36-EHPDACIQwith ducted air handler DM36E3J+TDR | ACIQ | 3 tons33,000 Btu/h · Ducted | 2.55 | 71% | 8.1 | 14.3 | CEE 25CEE 26XcelES CC | 9 | 217617068 |
| 111ACIQ-36-HP32ACIQ · R32 Extreme Heat Unitarywith ducted air handler ACIQ-36-AH32 | ACIQ | 3 tons34,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 18.2 | CEE 25CEE 26XcelES CC | 1 | 215387239 |
| 112ACIQ-36-HPDACIQwith ducted air handler DM36E3J+TDR | ACIQ | 3 tons33,000 Btu/h · Ducted | 2.53 | 76% | 8.1 | 15.2 | CEE 25CEE 26XcelES CC | 11 | 217617069 |
| 113ACIQ-36TD-HPACiQwith ducted air handler ACIQ-36TD-AH | ACIQ | 3 tons34,000 Btu/h · Ducted | 1.90 | 76% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 217006582 |
| 114ACIQ-36Z-HH-M5CACIQ · ACIQ Series | ACIQ | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.7 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 216032367 |
| 115ACIQ-36ZPL-HP230CACIQ · ACIQ Serieswith ducted air handler ACIQ-36CD-HH-MC | ACIQ | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.10 | 90% | 11.1 | 17.7 | CEE 25CEE 26XcelES CC | 3 | 216032348 |
| 116ACIQ-42-HPDACIQwith ducted air handler AE*L+DM59A4J+TDR | ACIQ | 3 tons38,500 Btu/h · Ducted | 2.81 | 78% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 8 | 218614991 |
| 117ACIQ-48-EHPDACIQwith ducted air handler AE*L+DM48E3J+TDR | ACIQ | 3.5 tons41,500 Btu/h · Ducted | 2.25 | 68% | 7.5 | 14.8 | CEE 25CEE 26XcelES CC | 6 | 217617039 |
| 118ACIQ-48-HP32ACIQ · R32 Extreme Heat Unitarywith ducted air handler ACIQ-48-AH32 | ACIQ | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 215387240 |
| 119ACIQ-48-HPDACIQwith ducted air handler AE*L+CM59A4J+TDR | ACIQ | 3.5 tons44,000 Btu/h · Ducted | 2.81 | 73% | 8.5 | 15.5 | CEE 25CEE 26XcelES CC | 18 | 217617038 |
| 120ACIQ-48Z-HH-M6CACIQ · ACIQ Series | ACIQ | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 216032370 |
| 121ACIQ-48ZPL-HP230CACIQ · ACIQ Serieswith ducted air handler ACIQ-48CC-HH-MC | ACIQ | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.00 | 91% | 10.8 | 16.7 | CEE 25CEE 26XcelES CC | 3 | 216032343 |
| 122ACIQ-55Z-HH-M6CACIQ · ACIQ Series | ACIQ | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 216032374 |
| 123ACIQ-60-HP32ACIQ · R32 Extreme Heat Unitarywith ducted air handler ACIQ-60-AH32 | ACIQ | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215387241 |
| 124ACIQ-60-HPDACIQwith ducted air handler CM59A4J+TDR | ACIQ | 4 tons45,000 Btu/h · Ducted | 2.14 | 62% | 7.5 | 14.8 | CEE 25CEE 26XcelES CC | 9 | 217617065 |
| 125ACIQ-K09Z-32-HP115BACiQwith ductless indoor unit ACIQ-K09W-BL-32-HP115B | ACIQ | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 80% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 2 | 218157782 |