Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ENERGY STAR Cold Climate: 5,143 qualifying heat pumps
Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).
New to heat pump ratings? The Simple view explains them in plain words →
U.S. EPAData as of updated · sources
- Share of models
- 41.7%
- Qualifying models
- 5,143
- Qualifying certifications
- 125,409
- Paths
- Listing
Criteria
No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.
Source: U.S. EPA
Qualification by size
- Up to 1.5 tons47.6% · 2,245 of 4,712
- 2 tons46.4% · 811 of 1,747
- 2.5–3 tons38.6% · 1,051 of 2,722
- 3.5–4.5 tons36.8% · 988 of 2,687
- 5 tons and up10.5% · 48 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 47.6% · 2,245 of 4,712 |
| 2 tons | 46.4% · 811 of 1,747 |
| 2.5–3 tons | 38.6% · 1,051 of 2,722 |
| 3.5–4.5 tons | 36.8% · 988 of 2,687 |
| 5 tons and up | 10.5% · 48 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 26.8% | 1,626 / 6,060 |
| Non-ducted | 42.2% | 1,722 / 4,081 |
| Ducted and non-ducted | 82.2% | 1,795 / 2,185 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 474 of 717 | 66.1% |
| Midea | 349 of 546 | 63.9% |
| Carrier | 218 of 816 | 26.7% |
| Ephoca | 186 of 382 | 48.7% |
| Innova | 161 of 332 | 48.5% |
| BlueRidge | 124 of 192 | 64.6% |
| TCL | 114 of 177 | 64.4% |
| Rheem | 114 of 341 | 33.4% |
| Mitsubishi Electric | 103 of 156 | 66% |
| Lennox | 99 of 331 | 29.9% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 4651TZP15AY42AJ2NTHERMAL ZONEwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | THERMAL ZONE | 3.5 tons39,000 Btu/h · Ducted | 2.20 | 51% | 7.8 | 15.2 | CEE 25ES CC | 67 | 217014484 |
| 4652TMFS24HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS24IDI2NAJ0H26 | THERMOFLUX | 2 tons24,000 Btu/h · Ducted | 1.85 | 100% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 218787998 |
| 4653TMFS36HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS36IDI2NAJ0H26 | THERMOFLUX | 3 tons36,000 Btu/h · Ducted | 1.85 | 100% | 9.5 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218787999 |
| 4654TMFS48HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS48IDI2NAJ0H26 | THERMOFLUX | 4 tons48,000 Btu/h · Ducted | 1.85 | 100% | 9.5 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218788000 |
| 4655TMFS55HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS55IDI2NAJ0H26 | THERMOFLUX | 4.5 tons54,000 Btu/h · Ducted | 1.85 | 93% | 9.5 | 17.0 | CEE 25CEE 26XcelES CC | 1 | 218788001 |
| 4656TIG12K115TOYOTOMI · T-Pro24SEERwith ductless indoor unit TIN12K115 | TOYOTOMI | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218636448 |
| 4657TIG18K230TOYOTOMI · T-Pro24SEERwith ductless indoor unit TIN18K230 | TOYOTOMI | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218636449 |
| 46585A5V0X36A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD04AV31+TDR | Trane | 2 tons26,200 Btu/h · Ducted | 2.27 | 107% | 10.3 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218792276 |
| 46595A5V0X48A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD06AV41+TDR | Trane | 3 tons36,000 Btu/h · Ducted | 1.93 | 100% | 9.7 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 218792278 |
| 46605A5V0X60A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,500 Btu/h · Ducted | 2.05 | 87% | 9.4 | 19.2 | CEE 25CEE 26XcelES CC | 1 | 218792280 |
| 46615A5V0X61A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,000 Btu/h · Ducted | 2.22 | 100% | 10.0 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218792282 |
| 46625A6H7024A1AMERICAN STANDARDwith ducted air handler CM24D3J+TDR | Trane | 2 tons21,000 Btu/h · Ducted | 2.87 | 111% | 8.1 | 15.5 | CEE 25CEE 26XcelES CC | 731 | 217155223 |
| 46635A6H7036A1AMERICAN STANDARDwith ducted air handler D(A,C,E)36B4J+TDR | Trane | 2.5 tons31,200 Btu/h · Ducted | 2.97 | 134% | 7.8 | 15.5 | CEE 25CEE 26XcelES CC | 1,188 | 217117484 |
| 46645A6H7048A1AMERICAN STANDARDwith ducted air handler AE*L+CM48B3J+TDR | Trane | 3.5 tons39,500 Btu/h · Ducted | 2.74 | 64% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 668 | 217155229 |
| 46655A6H7060A1AMERICAN STANDARDwith ducted air handler D(A,C,E)60B4J+TDR | Trane | 4 tons49,500 Btu/h · Ducted | 2.92 | 62% | 7.8 | 15.2 | CEE 25CEE 26XcelES CC | 422 | 217117491 |
| 46665A6V0X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRP | Trane | 1.5 tons19,500 Btu/h · Ducted | 2.93 | 98% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 167 | 217117128 |
| 46675A6V0X36A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD06AV41+TDR | Trane | 3 tons36,200 Btu/h · Ducted | 2.30 | 66% | 10.5 | 21.6 | CEE 25CEE 26XcelES CC | 136 | 217734495 |
| 46685A6V0X48A1AMERICAN STANDARD · PLATINUM 20with ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons46,000 Btu/h · Ducted | 2.24 | 73% | 10.0 | 20.4 | CEE 25CEE 26XcelES CC | 230 | 218788182 |
| 46695A6V0X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP | Trane | 4 tons50,000 Btu/h · Ducted | 2.70 | 90% | 8.5 | 19.0 | CEE 25CEE 26XcelES CC | 186 | 217117150 |
| 46705A6V8X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace S8V2A040M3PCB | Trane | 1.5 tons19,500 Btu/h · Ducted | 2.91 | 99% | 8.5 | 17.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 143 | 217117188 |
| 46715A6V8X36A1AMERICAN STANDARDwith indoor coil D(A,C,E)36B4J+TDR and furnace S9V2C080U5PSC+LRP | Trane | 2.5 tons30,400 Btu/h · Ducted | 2.88 | 93% | 7.8 | 18.0 | CEE 25CEE 26XcelES CC | 466 | 217117297 |
| 46725A6V8X48A1AMERICAN STANDARDwith indoor coil D(A,C,E)48B4J+TDR and furnace L8V1C100U5VSB+LRP | Trane | 3.5 tons42,500 Btu/h · Ducted | 2.87 | 93% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 410 | 217117338 |
| 46735A6V8X60A1AMERICAN STANDARDwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2C080U5VSB+LRP | Trane | 4 tons50,500 Btu/h · Ducted | 2.71 | 88% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 271 | 217117455 |
| 46745HCL5024A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5B03AC21 | Trane | 2 tons23,000 Btu/h · Ducted | 1.88 | 84% | 9.2 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 216772255 |
| 46755HCL5036A1TRANE · 5HCL5 Cold Climatewith ducted air handler 5TEM5B04AC31 | Trane | 3 tons34,000 Btu/h · Ducted | 1.90 | 100% | 9.4 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 216772256 |