ENERGY STAR Cold Climate: 5,144 qualifying heat pumps

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

New to heat pump ratings? The Simple view explains them in plain words →

U.S. EPAData as of updated · sources

Share of models
41.7%
Qualifying models
5,144
Qualifying certifications
125,479
Paths
Listing

Criteria

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.

Source: U.S. EPA

Qualification by size

Share of models meeting ENERGY STAR CC, by size
Show the data as a table
Share of models meeting ENERGY STAR CC, by size
GroupQualifying share
Up to 1.5 tons47.6% · 2,245 of 4,715
2 tons46.4% · 811 of 1,748
2.5–3 tons38.6% · 1,052 of 2,724
3.5–4.5 tons36.8% · 988 of 2,687
5 tons and up10.5% · 48 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted26.8%1,622 / 6,056
Non-ducted42.2%1,723 / 4,087
Ducted and non-ducted82.2%1,799 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree474 of 71766.1%
Midea349 of 54663.9%
Carrier218 of 81626.7%
Ephoca186 of 38248.7%
Innova161 of 33248.5%
BlueRidge124 of 19264.6%
TCL114 of 17764.4%
Rheem114 of 34133.4%
Mitsubishi Electric103 of 15666%
Lennox100 of 33729.7%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting ENERGY STAR Cold Climate, page 31 of 206
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
75137MPRAQ09AA3CARRIER · 45M Serieswith ductless indoor unit 45MPHAQ09XA3Carrier1 ton9,000 Btu/h · Non-ducted2.00113%14.633.5CEE 25CEE 26XcelES CC5215413142
75237MPRAQ12AA3CARRIER · 45M Serieswith ductless indoor unit 45MPHAQ12XA3Carrier1 ton12,000 Btu/h · Non-ducted2.00113%12.729.5CEE 25CEE 26XcelES CC5215413143
75337MPRAQ18AA3CARRIER · 45M Serieswith ductless indoor unit 45MPHAQ18XA3Carrier1.5 tons18,000 Btu/h · Non-ducted2.34113%—25.8XcelES CC5215413144
75437MTRAQ18CA3CARRIER · 37M SeriesCarrier1.5 tons18,000 Btu/h · Non-ducted2.0083%9.218.5CEE 25CEE 26XcelES CC4216765583
75537MTRAQ27DA3CARRIER · 37M SeriesCarrier2 tons26,400 Btu/h · Non-ducted2.0070%8.518.5CEE 25CEE 26XcelES CC4216765584
75637MTRAQ36EA3CARRIER · 37M SeriesCarrier3 tons36,000 Btu/h · Non-ducted1.9070%8.518.8XcelES CC4216765585
75737MTRAQ48FA3CARRIER · 37M SeriesCarrier4 tons48,000 Btu/h · Non-ducted1.8575%9.518.7CEE 25CEE 26XcelES CC4216765586
75837MUHAQ18AA3CARRIERwith indoor coil D(A,C,E)31A3J+TDR and furnace 58SU*B080M21**20Carrier1.5 tons17,200 Btu/h · Ducted3.3083%9.514.8CEE 25CEE 26CEE AdvXcelDOEES CC1,618218330915
75937MUHAQ18AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.0CEE 25CEE 26XcelES CC1,276218473019
76037MUHAQ18AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier1.5 tons18,000 Btu/h · Ducted3.1883%8.516.0CEE 25CEE 26XcelES CC1,446218330891
76137MUHAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons22,000 Btu/h · Ducted3.0698%8.515.5CEE 25CEE 26XcelES CC4,673218331062
76237MUHAQ24AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FJ5AN*B30LCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.0CEE 25CEE 26XcelES CC2,574218473449
76337MUHAQ24AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier2 tons23,200 Btu/h · Ducted2.6984%9.517.5CEE 25CEE 26XcelES CC2,456218330895
76437MUHAQ30AA3BRYANT HEATING AND COOLING SYSTEMSwith indoor coil D(A,C,E)36A3J+TDR and furnace 82*SB36070V14Carrier2.5 tons28,600 Btu/h · Ducted2.7364%7.814.3CEE 25CEE 26XcelES CC1,649217192006
76537MUHAQ30AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith indoor coil CAA**4321AM and furnace OVLAAB048112Carrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.5CEE 25CEE 26XcelES CC2,683218474076
76637MUHAQ30AA3+TIC2025-0016CARRIERwith indoor coil D(A,C,E)36A3J+TDR and furnace 58SU*B060M17**16Carrier2.5 tons27,000 Btu/h · Ducted2.7958%8.516.0CEE 25CEE 26XcelES CC2,727217894954
76737MUHAQ36AA3CARRIERwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons35,000 Btu/h · Ducted2.5078%8.015.2CEE 25CEE 26XcelES CC217217902903
76837MUHAQ36AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.5CEE 25CEE 26XcelES CC2,745218474651
76937MUHAQ36AA3+TIC2025-0016CARRIERwith indoor coil D(A,C,E)36A3J+TDR and furnace 58SP*B135V24**22Carrier2.5 tons32,800 Btu/h · Ducted2.2466%7.815.5CEE 25CEE 26XcelES CC2,617217895097
77037MUHAQ48AA3BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+CM59A4J+TDRCarrier3.5 tons44,000 Btu/h · Ducted2.9083%8.114.3CEE 25CEE 26XcelES CC348218076430
77137MUHAQ48AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler F55AA*D60LCarrier4 tons47,500 Btu/h · Ducted1.8093%8.514.3ES CC829218475858
77237MUHAQ60AA3CARRIERwith ducted air handler A(E,F)M60J+TDRCarrier4 tons47,000 Btu/h · Ducted2.4981%7.514.5CEE 25CEE 26XcelES CC235218693855
77337MUHAQ60AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler F55AA*D60LCarrier4.5 tons55,500 Btu/h · Ducted1.8090%9.015.0CEE 25CEE 26ES CC284218475856
77437MUHAQ60AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M60AJCarrier4 tons49,000 Btu/h · Ducted2.3584%8.115.2CEE 25CEE 26XcelES CC106218330903
77537MURAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons23,400 Btu/h · Ducted3.1687%8.514.3CEE 25CEE 26XcelES CC3,210218331338

Explore qualifying models by COP at 5°F