Skip to content

ENERGY STAR Cold Climate: 5,489 qualifying heat pumps

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

Simple view, for homeowners: top picks by size and what each rating measures →

U.S. EPAData as of updated · sources

Share of models
40.3%
Qualifying models
5,489
Qualifying certifications
134,768
Paths
Listing

Criteria

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.

Source: U.S. EPA

Qualification by size

Share of models meeting ENERGY STAR CC, by size
Show the data as a table
Share of models meeting ENERGY STAR CC, by size
GroupQualifying share
Up to 1.5 tons45% · 2,441 of 5,427
2 tons44.4% · 861 of 1,941
2.5 to 3 tons37.9% · 1,114 of 2,942
3.5 to 4.5 tons36.1% · 1,022 of 2,834
5 tons and up10.7% · 51 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted26.1%1,679 / 6,438
Non-ducted39.1%1,903 / 4,861
Ducted and non-ducted82.2%1,907 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree477 of 72965.4%
Midea355 of 55564%
Carrier232 of 84627.4%
Ephoca186 of 38248.7%
Innova186 of 38248.7%
BlueRidge125 of 19464.4%
TCL124 of 19264.6%
Rheem115 of 34633.2%
Mitsubishi Electric103 of 15666%
Lennox100 of 34129.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting ENERGY STAR Cold Climate, page 33 of 220
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
80137MPRAQ18AA3CARRIER · 45M Serieswith ductless indoor unit 45MPHAQ18XA3Carrier1.5 tons18,000 Btu/h · Non-ducted2.34113%—25.8XcelES CC6215413144
80237MTRAQ18CA3CARRIER · 37M SeriesCarrier1.5 tons18,000 Btu/h · Non-ducted2.0083%9.218.5CEE 25CEE 26XcelES CC4216765583
80337MTRAQ27DA3CARRIER · 37M SeriesCarrier2 tons26,400 Btu/h · Non-ducted2.0070%8.518.5CEE 25CEE 26XcelES CC4216765584
80437MTRAQ36EA3CARRIER · 37M SeriesCarrier3 tons36,000 Btu/h · Non-ducted1.9070%8.518.8XcelES CC4216765585
80537MTRAQ48FA3CARRIER · 37M SeriesCarrier4 tons48,000 Btu/h · Non-ducted1.8575%9.518.7CEE 25CEE 26XcelES CC4216765586
80637MUHAQ18AA3CARRIERwith indoor coil D(A,C,E)31A3J+TDR and furnace 58SU*B080M21**20Carrier1.5 tons17,200 Btu/h · Ducted3.3083%9.514.8CEE 25CEE 26CEE AdvXcelDOEES CC1,623218330915
80737MUHAQ18AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.0CEE 25CEE 26XcelES CC1,422218473019
80837MUHAQ18AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier1.5 tons18,000 Btu/h · Ducted3.1883%8.516.0CEE 25CEE 26XcelES CC1,446218330891
80937MUHAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons22,000 Btu/h · Ducted3.0698%8.515.5CEE 25CEE 26XcelES CC4,679218331062
81037MUHAQ24AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FJ5AN*B30LCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.0CEE 25CEE 26XcelES CC2,935218473449
81137MUHAQ24AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M36DJCarrier2 tons23,200 Btu/h · Ducted2.6984%9.517.5CEE 25CEE 26XcelES CC2,456218330895
81237MUHAQ30AA3BRYANT HEATING AND COOLING SYSTEMSwith indoor coil D(A,C,E)36A3J+TDR and furnace 82*SB36070V14Carrier2.5 tons28,600 Btu/h · Ducted2.7364%7.814.3CEE 25CEE 26XcelES CC1,656217192006
81337MUHAQ30AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith indoor coil CAA**4321AM and furnace OVLAAB048112Carrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.5CEE 25CEE 26XcelES CC2,924218474076
81437MUHAQ30AA3+TIC2025-0016CARRIERwith indoor coil D(A,C,E)36A3J+TDR and furnace 58SU*B060M17**16Carrier2.5 tons27,000 Btu/h · Ducted2.7958%8.516.0CEE 25CEE 26XcelES CC2,727217894954
81537MUHAQ36AA3CARRIERwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons35,000 Btu/h · Ducted2.5078%8.015.2CEE 25CEE 26XcelES CC223217902903
81637MUHAQ36AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.5CEE 25CEE 26XcelES CC2,813218474651
81737MUHAQ36AA3+TIC2025-0016CARRIERwith indoor coil D(A,C,E)36A3J+TDR and furnace 58SP*B135V24**22Carrier2.5 tons32,800 Btu/h · Ducted2.2466%7.815.5CEE 25CEE 26XcelES CC2,617217895097
81837MUHAQ48AA3BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+CM59A4J+TDRCarrier3.5 tons44,000 Btu/h · Ducted2.9083%8.114.3CEE 25CEE 26XcelES CC365218076430
81937MUHAQ48AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler F55AA*D60LCarrier4 tons47,500 Btu/h · Ducted1.8093%8.514.3ES CC887218475858
82037MUHAQ60AA3CARRIERwith ducted air handler A(E,F)M60J+TDRCarrier4 tons47,000 Btu/h · Ducted2.4981%7.514.5CEE 25CEE 26XcelES CC247218693855
82137MUHAQ60AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler F55AA*D60LCarrier4.5 tons55,500 Btu/h · Ducted1.8090%9.015.0CEE 25CEE 26ES CC320218475856
82237MUHAQ60AA3+TIC2025-0016CARRIERwith ducted air handler L(E,G)M60AJCarrier4 tons49,000 Btu/h · Ducted2.3584%8.115.2CEE 25CEE 26XcelES CC106218330903
82337MURAQ24AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons23,400 Btu/h · Ducted3.1687%8.514.3CEE 25CEE 26XcelES CC3,264218331338
82437MURAQ24AA3+KSAIC0701230CARRIER · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**ALCarrier2 tons24,800 Btu/h · Ducted2.1482%9.516.0CEE 25CEE 26XcelES CC1,806218475082
82537MURAQ36AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 58TP*B090V17**16Carrier3 tons34,800 Btu/h · Ducted2.6269%8.514.8CEE 25CEE 26XcelES CC2,598218331534

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter