ENERGY STAR Cold Climate: 5,144 qualifying heat pumps
Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).
New to heat pump ratings? The Simple view explains them in plain words →
U.S. EPAData as of updated · sources
- Share of models
- 41.7%
- Qualifying models
- 5,144
- Qualifying certifications
- 125,479
- Paths
- Listing
Criteria
No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.
Source: U.S. EPA
Qualification by size
- Up to 1.5 tons47.6% · 2,245 of 4,715
- 2 tons46.4% · 811 of 1,748
- 2.5–3 tons38.6% · 1,052 of 2,724
- 3.5–4.5 tons36.8% · 988 of 2,687
- 5 tons and up10.5% · 48 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 47.6% · 2,245 of 4,715 |
| 2 tons | 46.4% · 811 of 1,748 |
| 2.5–3 tons | 38.6% · 1,052 of 2,724 |
| 3.5–4.5 tons | 36.8% · 988 of 2,687 |
| 5 tons and up | 10.5% · 48 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 26.8% | 1,622 / 6,056 |
| Non-ducted | 42.2% | 1,723 / 4,087 |
| Ducted and non-ducted | 82.2% | 1,799 / 2,189 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 474 of 717 | 66.1% |
| Midea | 349 of 546 | 63.9% |
| Carrier | 218 of 816 | 26.7% |
| Ephoca | 186 of 382 | 48.7% |
| Innova | 161 of 332 | 48.5% |
| BlueRidge | 124 of 192 | 64.6% |
| TCL | 114 of 177 | 64.4% |
| Rheem | 114 of 341 | 33.4% |
| Mitsubishi Electric | 103 of 156 | 66% |
| Lennox | 100 of 337 | 29.7% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 826D5CPRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH12XAK | Carrier | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 113% | 12.7 | 28.0 | CEE 25CEE 26XcelES CC | 10 | 215413213 |
| 827D5CPRAH18AAARCOAIRE · D5F Serieswith ductless indoor unit D5FPHAH18XAK | Carrier | 1.5 tons18,000 Btu/h · Non-ducted | 2.34 | 113% | 15.2 | 24.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 10 | 215413214 |
| 828D5CSHAH06AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH06XAK | Carrier | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 27 | 215324104 |
| 829D5CSHAH09AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH12XAK | Carrier | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.89 | 112% | 12.5 | 21.5 | CEE 25CEE 26XcelES CC | 54 | 215324109 |
| 830D5CSHAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSOAH12XAK | Carrier | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 92% | 10.2 | 23.0 | CEE 25CEE 26XcelES CC | 54 | 215324112 |
| 831D5CSHAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH18XBK | Carrier | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.20 | 92% | 10.1 | 18.2 | CEE 25CEE 26XcelES CC | 73 | 215318904 |
| 832D5CSHAH24AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH24XAK | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.34 | 83% | 13.5 | 21.2 | CEE 25CEE 26XcelES CC | 46 | 215324124 |
| 833D5CSHAH33AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH36XBK | Carrier | 3 tons33,000 Btu/h · Ducted and non-ducted | 2.00 | 97% | 10.0 | 16.7 | CEE 25CEE 26XcelES CC | 19 | 215318906 |
| 834D5CSRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSHAH09XAK | Carrier | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.37 | 80% | 12.5 | 26.0 | CEE 25CEE 26XcelES CC | 54 | 215324130 |
| 835D5CSRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FSFAH12XAK | Carrier | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.51 | 74% | 11.0 | 24.7 | CEE 25CEE 26XcelES CC | 54 | 215324139 |
| 836D5CSRAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH18XHK | Carrier | 1.5 tons17,500 Btu/h · Ducted and non-ducted | 2.41 | 71% | 11.4 | 20.0 | CEE 25CEE 26XcelES CC | 73 | 215324148 |
| 837D5CSRAH24AAKARCOAIREwith ductless indoor unit D5FPHAH18XAK | Carrier | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.54 | 78% | 11.7 | 23.1 | CEE 25CEE 26XcelES CC | 56 | 215324149 |
| 838D5CUHAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 1.5 tons17,700 Btu/h · Ducted | 2.86 | 80% | 8.5 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,264 | 217906663 |
| 839D5CUHAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,400 Btu/h · Ducted | 2.04 | 83% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 1,684 | 218483199 |
| 840D5CUHAH18AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,400 Btu/h · Ducted | 2.04 | 83% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 1,804 | 217399865 |
| 841D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 2 tons23,800 Btu/h · Ducted | 2.88 | 79% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 5,101 | 217906665 |
| 842D5CUHAH24AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*B | Carrier | 2 tons24,200 Btu/h · Ducted | 2.06 | 83% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 4,433 | 218486193 |
| 843D5CUHAH24AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*B | Carrier | 2 tons24,200 Btu/h · Ducted | 2.06 | 83% | 9.0 | 16.0 | CEE 25CEE 26XcelES CC | 4,378 | 217635077 |
| 844D5CUHAH30AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 2.5 tons28,000 Btu/h · Ducted | 2.48 | 80% | 7.8 | 15.2 | CEE 25CEE 26XcelES CC | 1,045 | 217906667 |
| 845D5CUHAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16A | Carrier | 2.5 tons31,200 Btu/h · Ducted | 2.00 | 89% | 9.0 | 15.5 | CEE 25CEE 26XcelES CC | 4,115 | 218490362 |
| 846D5CUHAH30AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16A | Carrier | 2.5 tons31,200 Btu/h · Ducted | 2.00 | 89% | 9.0 | 15.5 | CEE 25CEE 26XcelES CC | 4,261 | 217396826 |
| 847D5CUHAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons35,000 Btu/h · Ducted | 2.14 | 74% | 8.0 | 15.2 | CEE 25CEE 26XcelES CC | 188 | 217906668 |
| 848D5CUHAH36AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Carrier | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | CEE 25CEE 26XcelES CC | 3,937 | 218495042 |
| 849D5CUHAH36AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Carrier | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | CEE 25CEE 26XcelES CC | 4,103 | 217486562 |
| 850D5CUHAH48AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDR | Carrier | 4 tons45,000 Btu/h · Ducted | 2.43 | 75% | 8.0 | 15.2 | CEE 25CEE 26XcelES CC | 219 | 217906669 |