Skip to content

ENERGY STAR Cold Climate: 5,144 qualifying heat pumps

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

New to heat pump ratings? The Simple view explains them in plain words →

U.S. EPAData as of updated · sources

Share of models
41.7%
Qualifying models
5,144
Qualifying certifications
125,485
Paths
Listing

Criteria

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.

Source: U.S. EPA

Qualification by size

Share of models meeting ENERGY STAR CC, by size
Show the data as a table
Share of models meeting ENERGY STAR CC, by size
GroupQualifying share
Up to 1.5 tons47.6% · 2,245 of 4,715
2 tons46.4% · 811 of 1,748
2.5–3 tons38.6% · 1,052 of 2,724
3.5–4.5 tons36.8% · 988 of 2,687
5 tons and up10.5% · 48 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted26.8%1,622 / 6,056
Non-ducted42.2%1,723 / 4,087
Ducted and non-ducted82.2%1,799 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree474 of 71766.1%
Midea349 of 54663.9%
Carrier218 of 81626.7%
Ephoca186 of 38248.7%
Innova161 of 33248.5%
BlueRidge124 of 19264.6%
TCL114 of 17764.4%
Rheem114 of 34133.4%
Mitsubishi Electric103 of 15666%
Lennox100 of 33729.7%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting ENERGY STAR Cold Climate, page 42 of 206
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1026WSEHV4860BA1-CCONTINENTAL · F Serieswith ducted air handler WPCC48ABA1CONTINENTAL4 tons47,000 Btu/h · Ducted1.8598%8.816.0CEE 25CEE 26XcelES CC4218696915
1027500004490Convectair · 500 Serieswith ductless indoor unit 500004479Convectair1 ton9,000 Btu/h · Non-ducted1.8096%12.526.0CEE 25CEE 26XcelES CC2216772608
1028500004492Convectair · 500 Serieswith ductless indoor unit 500004491Convectair1 ton12,000 Btu/h · Non-ducted1.8096%10.524.0CEE 25CEE 26XcelES CC2216772609
1029500004494Convectair · 500 Serieswith ductless indoor unit 500004493Convectair1.5 tons18,000 Btu/h · Non-ducted2.00100%10.821.7CEE 25CEE 26XcelES CC2216772610
1030500004496Convectair · 500 Serieswith ductless indoor unit 500004495Convectair2 tons23,000 Btu/h · Non-ducted2.0092%13.322.3CEE 25CEE 26XcelES CC2216772611
1031500006192Convectair · 500 SeriesConvectair3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00106%10.419.4CEE 25CEE 26XcelES CC3218001468
1032500006193Convectair · 500 SeriesConvectair4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0098%10.221.2CEE 25CEE 26XcelES CC3218001470
1033500006217Convectair · 500 SeriesConvectair1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.0CEE 25CEE 26XcelES CC3218001461
1034500006218Convectair · 500 SeriesConvectair2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%9.519.0CEE 25CEE 26XcelES CC3218001465
1035CH-ALT24HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP24AHU24VCooper&Hunter2 tons23,000 Btu/h · Ducted1.7871%8.716.4ES CC1218470841
1036CH-ALT30HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP30AHU24VCooper&Hunter2.5 tons30,000 Btu/h · Ducted1.9871%9.217.6ES CC1218470842
1037CH-ALT48HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP48AHU24VCooper&Hunter4 tons48,000 Btu/h · Ducted1.8570%8.215.2ES CC1218470843
1038CH-ALT60HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP60AHU24VCooper&Hunter4.5 tons54,000 Btu/h · Ducted1.8270%8.116.0ES CC1218470844
1039CH-PQ18-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ18AHUCooper&Hunter1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC8215864120
1040CH-PQ24-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ24AHUCooper&Hunter2 tons24,000 Btu/h · Ducted2.1486%10.018.6CEE 25CEE 26XcelES CC11215864121
1041CH-PQ33-230VOCooper&Hunter · CH Serieswith ducted air handler CH-STM30AHU24VCooper&Hunter2.5 tons30,000 Btu/h · Ducted2.00100%10.217.5CEE 25CEE 26XcelES CC12218470847
1042CH-PQ36-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ36AHUCooper&Hunter3 tons36,000 Btu/h · Ducted2.0691%10.017.7CEE 25CEE 26XcelES CC1215864123
1043CH-PQ36X-230VOCooper&Hunter · CH Serieswith ducted air handler CH-ACL30-36BCooper&Hunter3 tons36,000 Btu/h · Ducted1.9095%9.415.8CEE 25CEE 26XcelES CC8217732885
1044CH-PQ48-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ48AHUCooper&Hunter4 tons48,000 Btu/h · Ducted2.00100%9.517.5CEE 25CEE 26XcelES CC8215864124
1045CH-PQ55-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ55AHUCooper&Hunter4.5 tons54,000 Btu/h · Ducted1.9098%9.517.5CEE 25CEE 26XcelES CC6215864125
1046CH-R18MES-230VOCooper&Hunter · CH SeriesCooper&Hunter1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC3215864256
1047CH-R28MES-230VOCooper&Hunter · CH SeriesCooper&Hunter2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.0CEE 25CEE 26XcelES CC3215864257
1048CH-R36LCU-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH36LCCTCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.0CEE 25CEE 26XcelES CC5215864198
1049CH-R36MES-230VOCooper&Hunter · CH SeriesCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.0CEE 25CEE 26XcelES CC3215864260
1050CH-R48LCU-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RSH48LCCTCooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted2.0076%9.817.1CEE 25CEE 26XcelES CC5215864199

Explore qualifying models by COP at 5°F