Xcel Energy Colorado cold-climate ASHP (2025): 6,515 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,515
Qualifying certifications
189,411
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.6% · 2,905 of 4,715
2 tons60.8% · 1,062 of 1,748
2.5–3 tons50.3% · 1,369 of 2,724
3.5–4.5 tons42.1% · 1,130 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,933 / 6,056
Non-ducted63%2,573 / 4,087
Ducted and non-ducted91.8%2,009 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Lennox121 of 33735.9%
Ephoca120 of 38231.4%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 109 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2701SAP24HP230V1R32AOGREE · Airywith ductless indoor unit SAP24HP230V1R32AHGree2 tons22,000 Btu/h · Ducted and non-ducted1.80100%10.027.0CEE 25CEE 26XcelES CC4215283088
2702SPHP-B-36VBBAC Pro · B-Serieswith ducted air handler AIRH-B-24ME2BBGree2 tons24,000 Btu/h · Ducted2.1083%9.420.0CEE 25CEE 26XcelES CC2217464049
2703SPHP-B-60VBBAC Pro · B-Serieswith ducted air handler AIRH-B-48ME2BBGree4 tons47,500 Btu/h · Ducted2.1071%9.017.5CEE 25CEE 26XcelES CC2217464051
2704SPHP-X-I036BAC PROwith ducted air handler C(A,C,D,E)24B3J+TDRGree1.5 tons20,600 Btu/h · Ducted2.0460%8.115.5CEE 25CEE 26XcelES CC40218026214
2705SPHP-X-I060BAC PRO · X Serieswith ducted air handler AIRH-XB-060C1BGree4.5 tons53,000 Btu/h · Ducted2.10100%10.518.5CEE 25CEE 26CEE AdvXcelDOEES CC22217127818
2706SPHP-XB-I030BCAC PRO · XB Serieswith ducted air handler AIRH-XB-024C1BGree2 tons24,000 Btu/h · Ducted1.7579%8.318.5CEE 25CEE 26Xcel2217127806
2707SPHP-XB-I036BCAC PRO · XB Serieswith ducted air handler AIRH-XB-036C1BGree3 tons34,000 Btu/h · Ducted2.0064%8.319.0CEE 25CEE 26Xcel27217127804
2708SPHP-XB-I060BCAC PRO · XB Serieswith ducted air handler AIRH-XB-060C1BGree4.5 tons53,500 Btu/h · Ducted2.2474%9.519.0CEE 25CEE 26Xcel17217127803
2709SPHP-XT-36VBCAC PRO · XT Serieswith ducted air handler AIRH-XT-36MEMCCGree3 tons34,000 Btu/h · Ducted2.0074%8.517.5CEE 25CEE 26Xcel2218741534
2710SPHP-Y-V024BBAC PRO · SPHP Serieswith indoor coil COIL-Y-1824BMTB and furnace FURN-M-R2B60V12AGree2 tons24,000 Btu/h · Ducted1.9083%9.217.8CEE 25CEE 26XcelES CC10218471420
2711SPHP-Y-V036BBAC PRO · SPHP Serieswith ducted air handler AIRH-Y-V03612CBGree3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC9216497959
2712SPHP-Y-V048BBAC PRO · SPHP Serieswith ducted air handler AIRH-Y-V04816CBGree4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC5216497960
2713SPHP-Z-V018BBAC PRO · SPHP Serieswith ducted air handler AIRH-Z-V018V06CGree1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC7216497962
2714SPHP-Z-V024BBAC PRO · SPHP Serieswith ducted air handler AIRH-Z-V024V08CGree2 tons24,000 Btu/h · Ducted2.1486%10.018.6CEE 25CEE 26XcelES CC7216497963
2715SPHP-Z-V030BBAC PRO · SPHP Serieswith ducted air handler AIRH-Z-V030V10CGree2.5 tons30,000 Btu/h · Ducted1.97101%10.817.2CEE 25CEE 26XcelES CC4216497964
2716SPHP-Z-V036BBAC PRO · SPHP Serieswith ducted air handler AIRH-Z-V036V12CGree3 tons36,000 Btu/h · Ducted2.0691%10.017.7CEE 25CEE 26XcelES CC4216497965
2717SPHP-Z-V037BBAC PRO · SPHP Serieswith ducted air handler SMAH-Y-36EMBBGree3 tons36,000 Btu/h · Ducted1.9097%9.815.4XcelES CC1217556151
2718SPHP-Z-V048BBAC PRO · SPHP Serieswith ducted air handler AIRH-Z-V048V16CGree4 tons48,000 Btu/h · Ducted2.00100%9.517.5CEE 25CEE 26XcelES CC18216497966
2719SPHP-Z-V060BBAC PRO · SPHP Serieswith ducted air handler AIRH-Z-V060V18CGree4.5 tons54,000 Btu/h · Ducted1.9098%9.517.5CEE 25CEE 26XcelES CC14216497967
2720SU-AORAKI12-115/OTOSOT · AORAKIwith ductless indoor unit SU-AORAKI12-115/IGree1 ton12,000 Btu/h · Non-ducted1.9579%9.524.5CEE 25CEE 26XcelES CC1217023701
2721SU-AORAKI12-230/OTOSOT · AORAKIwith ductless indoor unit SU-AORAKI12-230/IGree1 ton12,000 Btu/h · Non-ducted1.9592%9.524.5CEE 25CEE 26XcelES CC2217023702
2722SU-AORAKI18-230/OTOSOT · AORAKIwith ductless indoor unit SU-AORAKI18-230/IGree1.5 tons18,000 Btu/h · Ducted and non-ducted1.9081%9.024.5CEE 25CEE 26XcelES CC4217023703
2723SU-AORAKI24-230/OTOSOT · All-matchwith ducted air handler SU-AORAKI24D/IGree2 tons22,000 Btu/h · Ducted and non-ducted1.8082%9.019.5CEE 25CEE 26XcelES CC4218636302
2724SU-AORAKI9-115/OTOSOT · AORAKIwith ductless indoor unit SU-AORAKI9-115/IGree1 ton9,100 Btu/h · Non-ducted1.8395%10.527.0CEE 25CEE 26XcelES CC1217023699
2725SU-AORAKI9-230/OTOSOT · 360°air discharge cassette unitwith ductless indoor unit SU-AORAKI9C/IGree1 ton9,100 Btu/h · Non-ducted1.9472%9.224.0CEE 25CEE 26XcelES CC2218636300

Explore qualifying models by COP at 5°F