Both views use the same certified data. This device remembers your choice.
Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
Simple view, for homeowners: top picks by size and what each rating measures →
Xcel EnergyData as of updated · sources
- Share of models
- 52.7%
- Qualifying models
- 7,174
- Qualifying certifications
- 197,833
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.7% · 3,292 of 5,427
- 2 tons59.4% · 1,152 of 1,941
- 2.5 to 3 tons50.4% · 1,483 of 2,942
- 3.5 to 4.5 tons42.2% · 1,195 of 2,834
- 5 tons and up10.9% · 52 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.7% · 3,292 of 5,427 |
| 2 tons | 59.4% · 1,152 of 1,941 |
| 2.5 to 3 tons | 50.4% · 1,483 of 2,942 |
| 3.5 to 4.5 tons | 42.2% · 1,195 of 2,834 |
| 5 tons and up | 10.9% · 52 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.2% | 2,070 / 6,438 |
| Non-ducted | 61.3% | 2,978 / 4,861 |
| Ducted and non-ducted | 91.6% | 2,126 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 387 of 555 | 69.7% |
| Carrier | 246 of 846 | 29.1% |
| TCL | 138 of 192 | 71.9% |
| BlueRidge | 132 of 194 | 68% |
| Daikin | 125 of 410 | 30.5% |
| AUX | 124 of 189 | 65.6% |
| Lennox | 121 of 341 | 35.5% |
| Ephoca | 120 of 382 | 31.4% |
| Innova | 120 of 382 | 31.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 2876KW09XQ19CDOKINGHOME · Charmowith ductless indoor unit KW09XQ19CDI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.94 | 76% | 8.8 | 20.5 | CEE 25CEE 26XcelES CC | 1 | 216772296 |
| 2877KW09XQ19SAOKINGHOME · Charmowith ductless indoor unit KW09XQ19SAI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.86 | 76% | 8.8 | 20.5 | CEE 25CEE 26XcelES CC | 1 | 217022902 |
| 2878KW09XQ19SDOKINGHOME · Charmowith ductless indoor unit KW09XQ19SDI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.94 | 76% | 8.8 | 20.5 | CEE 25CEE 26XcelES CC | 1 | 217022903 |
| 2879KW09XQ25PAOKINGHOME · Pularwith ductless indoor unit KW09XQ25PAI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.83 | 95% | 10.5 | 27.0 | CEE 25CEE 26XcelES CC | 1 | 216020671 |
| 2880KW09XQ25PDOKINGHOME · Pularwith ductless indoor unit KW09XQ25PDI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.88 | 90% | 10.4 | 26.0 | CEE 25CEE 26XcelES CC | 1 | 216020672 |
| 2881KW09XQ25S1AOKINGHOME · Cliviawith ductless indoor unit KW09XQ25S1AI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.83 | 95% | 10.5 | 27.0 | CEE 25CEE 26XcelES CC | 1 | 217933619 |
| 2882KW09XQ25S1DOKINGHOME · Ductedwith ducted air handler KM09XFDI | Gree | 1 ton9,100 Btu/h · Ducted and non-ducted | 2.14 | 90% | 9.2 | 22.0 | CEE 25CEE 26XcelES CC | 6 | 218451524 |
| 2883KW09XQ25SAOKINGHOME · Cliviawith ductless indoor unit KW09XQ25SAI | Gree | 1 ton9,100 Btu/h · Non-ducted | 1.83 | 95% | 10.5 | 27.0 | CEE 25CEE 26XcelES CC | 1 | 216372813 |
| 2884KW09XQ25SDOKINGHOME · Ductedwith ducted air handler KM09XFDI | Gree | 1 ton9,100 Btu/h · Ducted and non-ducted | 2.14 | 90% | 9.2 | 22.0 | CEE 25CEE 26XcelES CC | 6 | 216799636 |
| 2885KW09XQ29S1DOKINGHOME · Airywith ductless indoor unit KW09XQ29S1DI | Gree | 1 ton9,100 Btu/h · Ducted and non-ducted | 2.11 | 108% | 11.2 | 30.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 217903557 |
| 2886KW09XQ29SDOKINGHOME · Airywith ductless indoor unit KW09XQ29SDI | Gree | 1 ton9,100 Btu/h · Ducted and non-ducted | 2.11 | 108% | 11.2 | 30.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 215876648 |
| 2887KW12HQ19CAOKINGHOME · Charmowith ductless indoor unit KW12HQ19CAI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.81 | 71% | 8.5 | 19.0 | XcelES CC | 1 | 217956849 |
| 2888KW12HQ19CDOKINGHOME · Charmowith ductless indoor unit KW12HQ19CDI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 76% | 8.5 | 19.0 | XcelES CC | 1 | 217956851 |
| 2889KW12XQ19CAOKINGHOME · Charmowith ductless indoor unit KW12XQ19CAI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.81 | 71% | 8.5 | 19.0 | Xcel | 1 | 216772300 |
| 2890KW12XQ19CDOKINGHOME · Charmowith ductless indoor unit KW12XQ19CDI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 76% | 8.5 | 19.0 | XcelES CC | 1 | 216772298 |
| 2891KW12XQ19SAOKINGHOME · Charmowith ductless indoor unit KW12XQ19SAI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.81 | 71% | 8.5 | 19.0 | Xcel | 1 | 217022904 |
| 2892KW12XQ19SDOKINGHOME · Charmowith ductless indoor unit KW12XQ19SDI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 76% | 8.5 | 19.0 | Xcel | 1 | 217022905 |
| 2893KW12XQ25*1DOKINGHOME · Cliviawith ductless indoor unit KW12XQ25*1DI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.95 | 92% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 1 | 218448716 |
| 2894KW12XQ25PAOKINGHOME · Cliviawith ductless indoor unit KW12XQ25PAI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.95 | 79% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 1 | 216020674 |
| 2895KW12XQ25PDOKINGHOME · Cliviawith ductless indoor unit KW12XQ25PDI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.95 | 92% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 1 | 216020673 |
| 2896KW12XQ25S1AOKINGHOME · Cliviawith ductless indoor unit KW12XQ25S1AI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.95 | 79% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 1 | 217933618 |
| 2897KW12XQ25S1DOKINGHOME · Cliviawith ductless indoor unit KW12XQ25S1DI | Gree | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.95 | 92% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 6 | 217933620 |
| 2898KW12XQ25SAOKINGHOME · Cliviawith ductless indoor unit KW12XQ25SAI | Gree | 1 ton12,000 Btu/h · Non-ducted | 1.95 | 79% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 1 | 216372815 |
| 2899KW12XQ25SDOKINGHOME · Cliviawith ductless indoor unit KW12XQ25SDI | Gree | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.95 | 92% | 9.5 | 24.5 | CEE 25CEE 26XcelES CC | 6 | 216372816 |
| 2900KW12XQ29*DOKINGHOME · Airywith ductless indoor unit KW12XQ29*DI | Gree | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 100% | 10.0 | 29.5 | CEE 25CEE 26XcelES CC | 1 | 218448717 |