Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,515 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,515
Qualifying certifications
189,411
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.6% · 2,905 of 4,715
2 tons60.8% · 1,062 of 1,748
2.5–3 tons50.3% · 1,369 of 2,724
3.5–4.5 tons42.1% · 1,130 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,933 / 6,056
Non-ducted63%2,573 / 4,087
Ducted and non-ducted91.8%2,009 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Lennox121 of 33735.9%
Ephoca120 of 38231.4%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 192 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
4776NDHAMBB-48-ONAPOLEON · NDH SeriesNAPOLEON4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.0CEE 25CEE 26XcelES CC3217361788
4777NDHAS22BA-12-ONAPOLEON · NDH Serieswith ductless indoor unit NDHASCBB-12NAPOLEON1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.6CEE 25CEE 26XcelES CC4217605557
4778NDHAS22BA-18-ONAPOLEON · NDH Serieswith ducted air handler NDHASHDBB-18NAPOLEON1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.320.0CEE 25CEE 26XcelES CC4217605559
4779NDHAS22BA-24-ONAPOLEON · NDH Serieswith ductless indoor unit NDHAS4CBB-24NAPOLEON2 tons24,000 Btu/h · Ducted and non-ducted2.3074%10.522.0CEE 25CEE 26XcelES CC3217605553
4780NDHAS26BA-06-ONAPOLEON · NDH Serieswith ductless indoor unit NDHAS26BB-06-INAPOLEON0.5 tons6,000 Btu/h · Non-ducted2.40110%14.825.5CEE 25CEE 26CEE AdvXcelDOEES CC1217361765
4781NDHAS26BA-09-ONAPOLEON · NDH Serieswith ducted air handler NDHASHDBB-09NAPOLEON1 ton9,000 Btu/h · Ducted and non-ducted1.85120%13.820.5CEE 25CEE 26XcelES CC5217361775
4782NDHAS26BA-12-ONAPOLEON · NDH Serieswith ductless indoor unit NDHAS4CBB-12NAPOLEON1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.2CEE 25CEE 26XcelES CC5217361772
4783NDHAS26BA-18-ONAPOLEON · NDH Serieswith ducted air handler NDHASHDBB-18NAPOLEON1.5 tons17,500 Btu/h · Ducted and non-ducted2.1092%11.118.4CEE 25CEE 26XcelES CC5217361777
4784NDHAS26BA-24-ONAPOLEONwith ductless indoor unit NDHAS26BA-24-INAPOLEON2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.0CEE 25CEE 26XcelES CC3215931363
4785NDHAS26BA-33-ONAPOLEONwith ductless indoor unit NDHAS26BA-33-INAPOLEON3 tons33,000 Btu/h · Non-ducted1.9897%10.519.5CEE 25CEE 26XcelES CC2215931364
4786WSCHV0024BA1-NNapoleon · WSC Serieswith ducted air handler WECC24ABA1NAPOLEON2 tons24,000 Btu/h · Ducted1.8076%9.016.0CEE 25CEE 26XcelES CC2218461327
4787WSCHV0048BA1-NNapoleon · WSC Serieswith ducted air handler WECC60ABC1NAPOLEON4 tons45,000 Btu/h · Ducted1.8585%9.015.2XcelES CC1218461330
4788WSEHV2436BA1-CNAPOLEON · F Serieswith ducted air handler WPCC24ABA1NAPOLEON2 tons22,000 Btu/h · Ducted1.80100%8.516.0CEE 25CEE 26XcelES CC2218696911
4789WSEHV2436BA1-NNAPOLEON · F Serieswith ducted air handler WPFX36A-NNAPOLEON3 tons34,000 Btu/h · Ducted2.0089%10.018.5CEE 25CEE 26XcelES CC32216025738
4790WSEHV4860BA1-NNAPOLEONwith ducted air handler C(A,C,D,E)48C4J+TDRNAPOLEON4 tons45,000 Btu/h · Ducted2.0565%8.115.2CEE 25CEE 26XcelES CC12217109226
4791NAZ17V3622A1Navien, Inc.with ducted air handler FG33*36+TXV+AEFE4BNavien3 tons34,400 Btu/h · Ducted2.1068%8.819.0CEE 25CEE 26Xcel97218046994
4792NAZ17V6022A1Navien, Inc.with indoor coil FG49*60+TXV and furnace NPF700-100U5CHNavien4 tons46,500 Btu/h · Ducted2.1061%9.315.2CEE 25CEE 26Xcel52218046991
4793EZCENO24KNG Trade · EZC Serieswith ducted air handler EZCENI24KNG Trade2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC1216763022
4794EZCENO36KNG Trade · EZC Serieswith ducted air handler EZCENI36KNG Trade3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC1216763024
4795EZCENO48KNG Trade · EZC Serieswith ducted air handler EZCENI48KNG Trade4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC1216763025
4796MOBMH180DNG Trade · MOB SeriesNG Trade1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3077%10.020.0CEE 25CEE 26XcelES CC3216598389
4797MOBMH270DNG Trade · MOB SeriesNG Trade2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.523.0CEE 25CEE 26XcelES CC3216598391
4798MOBMH360DNG Trade · MOB SeriesNG Trade3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%10.023.1CEE 25CEE 26XcelES CC3216598394
4799MOBMH480DNG Trade · MOB SeriesNG Trade4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1075%10.021.3CEE 25CEE 26XcelES CC3216598397
4800MOSA32181NG TRADE · Multi-spilt seriesNG Trade1.5 tons17,700 Btu/h · Ducted and non-ducted2.0081%10.022.0CEE 25CEE 26XcelES CC2218029189

Explore qualifying models by COP at 5°F