Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel Energy Colorado cold-climate ASHP (2025): 6,515 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
New to heat pump ratings? The Simple view explains them in plain words →
Xcel EnergyData as of updated · sources
- Share of models
- 52.8%
- Qualifying models
- 6,515
- Qualifying certifications
- 189,411
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,238 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 519 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,401 |
| 75 to under 80% | 1,156 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 720 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,002 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,101 |
| 15.5 to under 16.0 | 284 |
| 16.0 to under 16.5 | 624 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 849 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 680 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 917 |
| 20.5 to under 21.0 | 162 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 18 |
| 27.0 to under 27.5 | 60 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 95 |
| 8.5 to under 9.0 | 214 |
| 9.0 to under 9.5 | 702 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 881 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,678 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,869 |
| 12.5 to under 13.0 | 951 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 274 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 179 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.5 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons61.6% · 2,905 of 4,715
- 2 tons60.8% · 1,062 of 1,748
- 2.5–3 tons50.3% · 1,369 of 2,724
- 3.5–4.5 tons42.1% · 1,130 of 2,687
- 5 tons and up10.7% · 49 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 61.6% · 2,905 of 4,715 |
| 2 tons | 60.8% · 1,062 of 1,748 |
| 2.5–3 tons | 50.3% · 1,369 of 2,724 |
| 3.5–4.5 tons | 42.1% · 1,130 of 2,687 |
| 5 tons and up | 10.7% · 49 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 31.9% | 1,933 / 6,056 |
| Non-ducted | 63% | 2,573 / 4,087 |
| Ducted and non-ducted | 91.8% | 2,009 / 2,189 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 574 of 717 | 80.1% |
| Midea | 381 of 546 | 69.8% |
| Carrier | 223 of 816 | 27.3% |
| BlueRidge | 131 of 192 | 68.2% |
| TCL | 128 of 177 | 72.3% |
| Lennox | 121 of 337 | 35.9% |
| Ephoca | 120 of 382 | 31.4% |
| Daikin | 117 of 394 | 29.7% |
| Rheem | 115 of 341 | 33.7% |
| Hisense | 110 of 161 | 68.3% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 4826DXH24PSK3IHGIBSON · (24-26 SEER2) Minisplitswith ductless indoor unit DHH24PUK3IH | Nortek Global HVAC | 2 tons22,000 Btu/h · Non-ducted | 1.80 | 79% | 10.0 | 26.0 | CEE 25CEE 26XcelES CC | 4 | 216011771 |
| 4827DXH30ESK3ILGIBSON · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH30ESK3IL | Nortek Global HVAC | 2.5 tons30,000 Btu/h · Non-ducted | 1.80 | 77% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 2 | 216011770 |
| 4828DXH30FMK3IHGIBSON · Multizone Outdoors | Nortek Global HVAC | 2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.07 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 6 | 215746312 |
| 4829DXH36ESK3ILGIBSON · (19-20.5 SEER2) Minisplitswith ductless indoor unit DHH36ESK3IL | Nortek Global HVAC | 3 tons33,600 Btu/h · Non-ducted | 1.80 | 72% | 8.5 | 21.0 | CEE 25CEE 26XcelES CC | 2 | 216011763 |
| 4830DXH36FMK3IHGIBSON · Multizone Outdoors | Nortek Global HVAC | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 215746313 |
| 4831DXH42FMK3IHGIBSON · Multizone Outdoors | Nortek Global HVAC | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 6 | 215746314 |
| 4832UXH24-36MSK3IHGibson · E Serieswith ducted air handler UMD24MSK3IH | Nortek Global HVAC | 2 tons24,000 Btu/h · Ducted | 2.00 | 96% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 14 | 217138206 |
| 4833UXH48-60MSK3IHGibson · E Serieswith ducted air handler UMD60MSK3IH | Nortek Global HVAC | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 217138209 |
| 4834WHS18SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS18WMB21S | Nortek Global HVAC | 1.5 tons18,000 Btu/h · Non-ducted | 2.53 | 74% | 9.8 | 20.0 | CEE 25CEE 26Xcel | 1 | 217101981 |
| 4835WHS24SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS24WMB21S | Nortek Global HVAC | 2 tons24,000 Btu/h · Non-ducted | 1.98 | 76% | 9.0 | 19.5 | CEE 25CEE 26Xcel | 1 | 217101982 |
| 4836WHS30SZB21SWESTINGHOUSE · S**SZB2with ductless indoor unit WHS30WMB21S | Nortek Global HVAC | 2.5 tons30,000 Btu/h · Non-ducted | 2.00 | 71% | 8.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 217101983 |
| 4837TSC-NCC454-12HA1/I3TI22NORTHCO CLIMAT.CA · NORTHCO CLIMAT.CAwith ductless indoor unit TSC-NCC454-12HA1/I3TI22 | NORTHCO CLIMAT.CA | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217563535 |
| 4838TSC-NCC454-18HA1/I3T121NORTHCO CLIMAT.CA · NORTHCO CLIMAT.CAwith ductless indoor unit TSC-NCC454-18HA1/I3T121 | NORTHCO CLIMAT.CA | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217563536 |
| 4839OHP-09-22-23-ANORTON AIR CONDITIONERS · OHP Serieswith ductless indoor unit DHP-09-12-U-A | NORTON AIR CONDITIONERS | 1 ton9,000 Btu/h · Non-ducted | 2.33 | 82% | 13.0 | 24.6 | CEE 25CEE 26XcelES CC | 1 | 217500258 |
| 4840NOVA-HE12-EXTNOVA · T-Prowith ductless indoor unit NOVA-HE12-INT | NOVA | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217731075 |
| 4841NOVA-HE18-EXTNOVA · T-Prowith ductless indoor unit NOVA-HE18-INT | NOVA | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217731076 |
| 4842NOVA-MULTI27M3NOVA · T-Pro | NOVA | 2.5 tons27,000 Btu/h · Non-ducted | 2.00 | 71% | 10.5 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217731073 |
| 4843NOVA-MULTI36M4NOVA · T-Pro | NOVA | 3 tons35,000 Btu/h · Non-ducted | 2.00 | 72% | 10.0 | 22.5 | CEE 25CEE 26XcelES CC | 1 | 217731074 |
| 4844NOVA-MULTI42M5NOVA · T-Pro | NOVA | 3.5 tons42,000 Btu/h · Non-ducted | 2.00 | 71% | 10.0 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 217731077 |
| 4845LEA06HH-SK-ONOVAIR · LEA Serieswith ductless indoor unit LEA06HH-SK-I | NOVAIR | 0.5 tons6,000 Btu/h · Non-ducted | 2.00 | 150% | 15.6 | 35.0 | CEE 25CEE 26XcelES CC | 1 | 218788019 |
| 4846LEA06SZ36-ONOVAIR · LEA Serieswith ducted air handler LEA06DUCT-I | NOVAIR | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 217606302 |
| 4847LEA09HH-SK-ONOVAIR · LEA Serieswith ductless indoor unit LEA09HH-SK-I | NOVAIR | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 113% | 14.6 | 33.3 | CEE 25CEE 26XcelES CC | 1 | 218788020 |
| 4848LEA09SZ26-ONOVAIR · LEA Serieswith ductless indoor unit 4LEA09USK-I | NOVAIR | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.37 | 80% | 12.5 | 25.8 | CEE 25CEE 26XcelES CC | 5 | 217606294 |
| 4849LEA09SZ36-ONOVAIR · LEA Serieswith ducted air handler LEA09DUCT-I | NOVAIR | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.89 | 112% | 12.5 | 21.4 | CEE 25CEE 26XcelES CC | 5 | 217606303 |
| 4850LEA12HH-SK-ONOVAIR · LEA Serieswith ductless indoor unit LEA12HH-SK-I | NOVAIR | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 113% | 12.7 | 29.4 | CEE 25CEE 26XcelES CC | 1 | 218788021 |