Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,512 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,512
Qualifying certifications
188,425
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,218 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,237
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,153 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,157
80 to under 85%798
85 to under 90%375
90 to under 95%719
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,323 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,102
15.5 to under 16.0283
16.0 to under 16.5623
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5915
20.5 to under 21.0161
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,319 rated models · median 11.697% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0213
9.0 to under 9.5700
9.5 to under 10.0831
10.0 to under 10.5880
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0950
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.6
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.7% · 2,905 of 4,712
2 tons60.8% · 1,062 of 1,747
2.5–3 tons50.2% · 1,367 of 2,722
3.5–4.5 tons42% · 1,129 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,935 / 6,060
Non-ducted63%2,572 / 4,081
Ducted and non-ducted91.8%2,005 / 2,185

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Ephoca120 of 38231.4%
Lennox118 of 33135.6%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 237 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
59015HPL5060A1AMERICAN STANDARDwith ducted air handler L(E,G)M60DJTrane4 tons47,000 Btu/h · Ducted1.89102%7.515.2Xcel17217106839
59025TCV0X36A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD04AV31+TDRTrane2 tons26,200 Btu/h · Ducted2.27107%10.320.0CEE 25CEE 26CEE AdvXcelDOEES CC1218792275
59035TCV0X48A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD06AV41+TDRTrane3 tons36,000 Btu/h · Ducted1.93100%9.719.0CEE 25CEE 26XcelES CC1218792277
59045TCV0X60A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRTrane4 tons48,500 Btu/h · Ducted2.0587%9.419.2CEE 25CEE 26XcelES CC1218792279
59055TCV0X61A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRTrane4 tons48,000 Btu/h · Ducted2.22100%10.018.0CEE 25CEE 26CEE AdvXcelDOEES CC1218792281
59065TWR5036A1TRANEwith indoor coil DH60T4J and furnace S8V2B080M4PCBTrane3 tons33,200 Btu/h · Ducted3.0870%8.516.0CEE 25CEE 26Xcel2,223216952729
59075TWR5060A1TRANEwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted3.0670%8.115.5Xcel642216952883
59085TWR7024A1TRANEwith ducted air handler CM36B4J+TDRTrane2 tons21,600 Btu/h · Ducted2.85111%8.116.0CEE 25CEE 26XcelES CC552217754352
59095TWR7036A1TRANEwith ducted air handler CM36B4J+TDRTrane2.5 tons31,200 Btu/h · Ducted2.97135%7.815.2CEE 25CEE 26XcelES CC1,024217754353
59105TWR7048A1TRANEwith indoor coil DH60T4J and furnace S8X1D120M5PSCTrane3.5 tons43,000 Btu/h · Ducted2.4267%9.017.5CEE 25CEE 26XcelES CC499217208283
59115TWR7060A1TRANEwith indoor coil DH60T4J and furnace S9V2D120U5PSCTrane4.5 tons51,000 Btu/h · Ducted2.4166%9.016.0CEE 25CEE 26XcelES CC274217208370
59125TWV0X24A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCBTrane1.5 tons19,800 Btu/h · Ducted2.99122%10.021.2CEE 25CEE 26CEE AdvXcelDOEES CC185216794262
59135TWV0X36A1TRANE · 20 TruComfort Variable Speed Heat Pumpwith ducted air handler 5TEMCD06AV41+TDRTrane3 tons36,200 Btu/h · Ducted2.3066%10.521.6CEE 25CEE 26XcelES CC114217734494
59145TWV0X48A1TRANEwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRPTrane3.5 tons41,500 Btu/h · Ducted2.81108%9.520.2CEE 25CEE 26CEE AdvXcelDOEES CC207216794596
59155TWV0X60A1TRANE · 20 TruComfort Variable Speed Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRTrane4.5 tons54,500 Btu/h · Ducted2.1173%9.419.2CEE 25CEE 26XcelES CC118218788183
59165TWV8X24A1TRANE · 18 TruComfort Variable Speed Heat Pumpwith indoor coil 5PX*BD06AS3 and furnace S9V2B080D4VSB+VCKITTrane2 tons22,000 Btu/h · Ducted2.2778%8.518.1CEE 25CEE 26XcelES CC104218036461
59175TWV8X36A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCBTrane2.5 tons29,800 Btu/h · Ducted2.85115%8.518.0CEE 25CEE 26CEE AdvXcelDOEES CC255216797087
59185TWV8X48A1TRANEwith indoor coil D(A,C,E)48C3J+TDR and furnace S8V2C080M5PCBTrane4 tons45,000 Btu/h · Ducted2.89115%7.818.0CEE 25CEE 26CEE AdvXcelDOEES CC215216797145
59195TWV8X60A1TRANE · 18 TruComfort Variable Speed Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRTrane4.5 tons55,500 Btu/h · Ducted2.1174%8.518.1CEE 25CEE 26XcelES CC137218788187
59205TWX5030A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCBTrane2 tons26,200 Btu/h · Ducted2.7968%7.815.5CEE 25CEE 26Xcel1,833217337497
59215TWX5036A1TRANEwith indoor coil DH36T4J and furnace S9X1D120U5PSBTrane2.5 tons32,000 Btu/h · Ducted3.0372%8.116.0CEE 25CEE 26Xcel1,981216951991
59225TWX5060A1TRANEwith indoor coil DH60T4J and furnace L8V1C100U5VSBTrane4.5 tons52,500 Btu/h · Ducted2.9170%7.515.5Xcel492216953013
59235TWX7024A1TRANEwith ducted air handler L(E,G)M36CJTrane2 tons21,800 Btu/h · Ducted2.4670%8.116.0CEE 25CEE 26XcelES CC546218350179
59245TWX7036A1TRANEwith indoor coil DH60T4J and furnace L8V1A040U3VSBTrane2.5 tons32,200 Btu/h · Ducted2.2965%8.517.0CEE 25CEE 26XcelES CC1,024217208633
59255TWX7048A1TRANEwith indoor coil DH60T4J and furnace S8X1D120M5PSCTrane3.5 tons43,000 Btu/h · Ducted2.3267%9.017.5CEE 25CEE 26XcelES CC453217209013

Explore qualifying models by COP at 5°F