Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,512 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,512
Qualifying certifications
188,425
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,218 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,237
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,153 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,157
80 to under 85%798
85 to under 90%375
90 to under 95%719
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,323 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,102
15.5 to under 16.0283
16.0 to under 16.5623
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5915
20.5 to under 21.0161
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,319 rated models · median 11.697% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0213
9.0 to under 9.5700
9.5 to under 10.0831
10.0 to under 10.5880
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0950
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.6
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.7% · 2,905 of 4,712
2 tons60.8% · 1,062 of 1,747
2.5–3 tons50.2% · 1,367 of 2,722
3.5–4.5 tons42% · 1,129 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,935 / 6,060
Non-ducted63%2,572 / 4,081
Ducted and non-ducted91.8%2,005 / 2,185

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Ephoca120 of 38231.4%
Lennox118 of 33135.6%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 238 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
59265TWX7060A1TRANEwith indoor coil DH60T4J and furnace S8V2D120M5PCBTrane4.5 tons51,000 Btu/h · Ducted2.3267%8.515.5CEE 25CEE 26XcelES CC276217209080
5927A5HL5024A1RUNTRUwith ducted air handler L(E,F)W36DJTrane2 tons21,200 Btu/h · Ducted2.0386%7.815.2CEE 25CEE 26XcelES CC189217221781
5928A5HL5024A1000AARUNTRU · A5HL5with ducted air handler A5AHV002A1B3Trane2 tons23,000 Btu/h · Ducted1.7578%8.116.0CEE 25CEE 26XcelES CC8216439103
5929A5HL5036A1RUNTRUwith ducted air handler CM36B4J+TDRTrane2.5 tons28,400 Btu/h · Ducted1.97109%8.114.3CEE 25CEE 26XcelES CC163218034123
5930A5HL5036A1000AARUNTRU · A5HL5with ducted air handler A5AHV004A1D3Trane3 tons34,000 Btu/h · Ducted1.7579%8.116.0CEE 25CEE 26XcelES CC8216439104
5931A5HL5048A1AMERISTAR · A5HL5with indoor coil 5TXCB006AS3 and furnace A952V060BU4SBTrane3.5 tons41,000 Btu/h · Ducted1.8080%8.115.2CEE 25CEE 26XcelES CC170217162406
5932A5HL5048A1000AARUNTRU · A5HL5with ducted air handler A5AHV006A1D3Trane4 tons46,000 Btu/h · Ducted1.7579%8.116.0CEE 25CEE 26XcelES CC8216439106
5933A5HL5060A1RUNTRU · A5HL5with ducted air handler A5AHV007A1D3Trane4.5 tons53,000 Btu/h · Ducted1.7578%8.116.0Xcel5216776159
5934A5HP5036A1RUNTRUwith indoor coil D(A,C,E)36C3J+TDR and furnace A801X080CM5SDTrane2.5 tons31,200 Btu/h · Ducted3.0071%8.515.2CEE 25CEE 26Xcel1,032217083701
5935M3THS2209A91NARunTru · CXVwith ductless indoor unit M3MHW2209A9N0ATrane1 ton9,000 Btu/h · Non-ducted1.7576%9.523.5CEE 25CEE 26Xcel2212586155
5936M3THS2212A91NARunTru · CXVwith ductless indoor unit M3MHW2212A9N0ATrane1 ton12,000 Btu/h · Non-ducted1.7575%9.523.0CEE 25CEE 26Xcel2212586156
5937M5THM2318A12NA*RunTru · 23U MultiTrane1.5 tons18,000 Btu/h · Non-ducted2.0080%10.524.0CEE 25CEE 26XcelES CC2218067082
5938M5THM2327A13NA*RunTru · 23U MultiTrane2.5 tons27,000 Btu/h · Non-ducted2.0071%10.524.0CEE 25CEE 26XcelES CC2218067083
5939M5THM2336A14NA*RunTru · 23U MultiTrane3 tons35,000 Btu/h · Non-ducted2.0072%10.022.5CEE 25CEE 26XcelES CC2218067084
5940M5THM2342A15NA*RunTru · 23U MultiTrane3.5 tons42,000 Btu/h · Non-ducted2.0071%10.022.0CEE 25CEE 26XcelES CC2218067085
5941M5THS1909A11NA*RunTruwith ductless indoor unit M5MHWUN09B1N0ATrane1 ton9,000 Btu/h · Non-ducted1.9071%9.519.0CEE 25CEE 26Xcel2218067098
5942M5THS1909A11NAARunTruwith ductless indoor unit M5MHWUN09A1N0AATrane1 ton9,000 Btu/h · Non-ducted1.8471%9.519.0CEE 25CEE 26Xcel2215385442
5943M5THS1912A11NA*RunTruwith ductless indoor unit M5MHWUN12B1N0ATrane1 ton12,000 Btu/h · Non-ducted2.1072%10.019.0CEE 25CEE 26Xcel2218067099
5944M5THS1912A11NAARunTruwith ductless indoor unit M5MHWUN12A1N0AATrane1 ton12,000 Btu/h · Non-ducted2.1072%10.019.0CEE 25CEE 26Xcel2215385443
5945M5THS1918A11NA*RunTruwith ductless indoor unit M5MHWUN18B1N0ATrane1.5 tons18,000 Btu/h · Non-ducted1.8072%10.019.0CEE 25CEE 26Xcel2218067100
5946M5THS1918A11NAARunTruwith ductless indoor unit M5MHWUN18A1N0AATrane1.5 tons18,000 Btu/h · Non-ducted1.8072%10.019.0CEE 25CEE 26Xcel2215385444
5947M5THS1924A11NA*RunTruwith ductless indoor unit M5MHWUN24B1N0ATrane2 tons23,000 Btu/h · Non-ducted1.8076%9.519.0CEE 25CEE 26Xcel2218067101
5948M5THS1924A11NAARunTruwith ductless indoor unit M5MHWUN24A1N0AATrane2 tons23,000 Btu/h · Non-ducted1.8076%9.519.0CEE 25CEE 26Xcel2215385445
5949M5THS2309A11NA*RunTru · 23U Serieswith ductless indoor unit M5MHWUN09B1N0ATrane1 ton9,000 Btu/h · Non-ducted1.8471%9.523.0CEE 25CEE 26XcelES CC2218067090
5950M5THS2309A11NAARunTru · 23U Serieswith ductless indoor unit M5MHWUN09A1N0AATrane1 ton9,000 Btu/h · Non-ducted1.8471%9.523.0CEE 25CEE 26XcelES CC2215385434

Explore qualifying models by COP at 5°F