Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel Energy Colorado cold-climate ASHP (2025): 6,512 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
New to heat pump ratings? The Simple view explains them in plain words →
Xcel EnergyData as of updated · sources
- Share of models
- 52.8%
- Qualifying models
- 6,512
- Qualifying certifications
- 187,787
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,237 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 519 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,400 |
| 75 to under 80% | 1,157 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 719 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,002 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,103 |
| 15.5 to under 16.0 | 282 |
| 16.0 to under 16.5 | 623 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 848 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 680 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 916 |
| 20.5 to under 21.0 | 160 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 18 |
| 27.0 to under 27.5 | 60 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 95 |
| 8.5 to under 9.0 | 213 |
| 9.0 to under 9.5 | 700 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 880 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,678 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,870 |
| 12.5 to under 13.0 | 949 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 274 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 179 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.6 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons61.7% · 2,905 of 4,712
- 2 tons60.8% · 1,062 of 1,747
- 2.5–3 tons50.2% · 1,367 of 2,722
- 3.5–4.5 tons42% · 1,129 of 2,687
- 5 tons and up10.7% · 49 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 61.7% · 2,905 of 4,712 |
| 2 tons | 60.8% · 1,062 of 1,747 |
| 2.5–3 tons | 50.2% · 1,367 of 2,722 |
| 3.5–4.5 tons | 42% · 1,129 of 2,687 |
| 5 tons and up | 10.7% · 49 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 31.9% | 1,935 / 6,060 |
| Non-ducted | 63% | 2,572 / 4,081 |
| Ducted and non-ducted | 91.8% | 2,005 / 2,185 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 574 of 717 | 80.1% |
| Midea | 381 of 546 | 69.8% |
| Carrier | 223 of 816 | 27.3% |
| BlueRidge | 131 of 192 | 68.2% |
| TCL | 128 of 177 | 72.3% |
| Ephoca | 120 of 382 | 31.4% |
| Lennox | 118 of 331 | 35.6% |
| Daikin | 117 of 394 | 29.7% |
| Rheem | 115 of 341 | 33.7% |
| Hisense | 110 of 161 | 68.3% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 6101D5CUHAH24AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons23,600 Btu/h · Ducted | 2.04 | 84% | 9.5 | 17.5 | CEE 25CEE 26XcelES CC | 2 | 218475400 |
| 6102D5CUHAH24AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons23,600 Btu/h · Ducted | 2.04 | 84% | 9.5 | 17.5 | CEE 25CEE 26Xcel | 2 | 217753142 |
| 6103D5CUHAH30AAKViessmann · D5C Serieswith ducted air handler D5MUWAQ30XA3 | Viessmann | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 100% | 10.2 | 17.5 | CEE 25CEE 26XcelES CC | 6 | 218668523 |
| 6104D5CUHAH30AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 2.5 tons31,200 Btu/h · Ducted | 1.92 | 86% | 9.0 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 218492014 |
| 6105D5CUHAH30AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 2.5 tons31,200 Btu/h · Ducted | 1.92 | 86% | 9.0 | 16.5 | CEE 25CEE 26Xcel | 3 | 217753146 |
| 6106D5CUHAH36AAKViessmann · D5C Serieswith ducted air handler D5FUAAH36XAK | Viessmann | 3 tons36,000 Btu/h · Ducted | 1.90 | 105% | 10.3 | 17.4 | CEE 25CEE 26XcelES CC | 9 | 217178767 |
| 6107D5CUHAH36AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | CEE 25CEE 26XcelES CC | 2 | 218496432 |
| 6108D5CUHAH36AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 3 tons36,200 Btu/h · Ducted | 1.90 | 79% | 9.0 | 16.5 | CEE 25CEE 26Xcel | 2 | 217753148 |
| 6109D5CUHAH48AAKViessmann · D5C Serieswith ducted air handler D5FUHAH60XAK | Viessmann | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 9.5 | 17.5 | CEE 25CEE 26XcelES CC | 4 | 217178774 |
| 6110D5CUHAH60AAKViessmann · D5C Serieswith ducted air handler D5FUHAH60XAK | Viessmann | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 98% | 9.5 | 17.5 | CEE 25CEE 26XcelES CC | 6 | 217178771 |
| 6111D5CUHAH60AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5B60L0D | Viessmann | 4.5 tons54,500 Btu/h · Ducted | 1.84 | 88% | 9.0 | 16.0 | CEE 25CEE 26Xcel | 1 | 217753140 |
| 6112D5CURAH24AAKVIESSMANN · Crossover heat pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons24,000 Btu/h · Ducted | 1.98 | 81% | 9.0 | 15.5 | CEE 25CEE 26XcelES CC | 8 | 217753132 |
| 6113D5CURAH24AAK+KSAIC0701230VIESSMANN · Crossover heat pumpwith ducted air handler FTMA5X24L0B | Viessmann | 2 tons24,000 Btu/h · Ducted | 1.98 | 81% | 9.0 | 15.5 | CEE 25CEE 26XcelES CC | 2 | 218475424 |
| 6114D5CURAH36AAKVIESSMANN · Crossover Heat Pumpwith ducted air handler FMA5X36**AL | Viessmann | 3 tons37,400 Btu/h · Ducted | 2.24 | 64% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 10 | 217753153 |
| 6115D5CURAH48AAKViessmann · D5C Serieswith ducted air handler D5FUAAH48XAK | Viessmann | 4 tons48,000 Btu/h · Ducted | 1.85 | 79% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 217178779 |
| 6116VHP-UCHA-24HDCTVillarawith ducted air handler VAH-UCHA-24HDC | Villara | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 217081897 |
| 6117VHP-UCHA-36HDCTVillara · T Serieswith ducted air handler VAH-UCHA-36HDC | Villara | 3 tons34,200 Btu/h · Ducted | 2.20 | 73% | 9.0 | 18.5 | CEE 25CEE 26Xcel | 1 | 217001204 |
| 6118VHP-UCHA-48HDCTVillarawith ducted air handler VAH-UCHA-48HDC | Villara | 4 tons48,000 Btu/h · Ducted | 2.20 | 73% | 9.8 | 18.5 | CEE 25CEE 26Xcel | 1 | 217081898 |
| 6119VHP-UCA-24HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-24HDC-A | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218030989 |
| 6120VHP-UCA-36HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-36HDC-A | VillaTherm | 3 tons34,200 Btu/h · Ducted | 2.20 | 73% | 9.0 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218030990 |
| 6121VHP-UCA-48HDC-AVillaTherm · T2 Serieswith ducted air handler VAH-UCA-48HDC-A | VillaTherm | 4 tons48,000 Btu/h · Ducted | 2.20 | 73% | 9.8 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218030991 |
| 6122VHP-UCHA-24HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-24HDCSN4 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 217753628 |
| 6123VHP-UCHA-24HDCTVillaTherm · T Serieswith ducted air handler VAH-UCHA-24HDC | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 74% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 217155424 |
| 6124VHP-UCHA-24HDCT-AVillaTherm · SPLIT AHUwith ducted air handler VAH-UCHA-24SHDCALN2 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.30 | 100% | 10.2 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 218696917 |
| 6125VHP-UCHA-36HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-36HDCSN4 | VillaTherm | 3 tons34,200 Btu/h · Ducted | 2.10 | 76% | 9.0 | 18.0 | CEE 25CEE 26Xcel | 1 | 217753629 |