Both views use the same certified data. This device remembers your choice.
Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
Simple view, for homeowners: top picks by size and what each rating measures →
Xcel EnergyData as of updated · sources
- Share of models
- 52.7%
- Qualifying models
- 7,174
- Qualifying certifications
- 197,833
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.7% · 3,292 of 5,427
- 2 tons59.4% · 1,152 of 1,941
- 2.5 to 3 tons50.4% · 1,483 of 2,942
- 3.5 to 4.5 tons42.2% · 1,195 of 2,834
- 5 tons and up10.9% · 52 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.7% · 3,292 of 5,427 |
| 2 tons | 59.4% · 1,152 of 1,941 |
| 2.5 to 3 tons | 50.4% · 1,483 of 2,942 |
| 3.5 to 4.5 tons | 42.2% · 1,195 of 2,834 |
| 5 tons and up | 10.9% · 52 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.2% | 2,070 / 6,438 |
| Non-ducted | 61.3% | 2,978 / 4,861 |
| Ducted and non-ducted | 91.6% | 2,126 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 387 of 555 | 69.7% |
| Carrier | 246 of 846 | 29.1% |
| TCL | 138 of 192 | 71.9% |
| BlueRidge | 132 of 194 | 68% |
| Daikin | 125 of 410 | 30.5% |
| AUX | 124 of 189 | 65.6% |
| Lennox | 121 of 341 | 35.5% |
| Ephoca | 120 of 382 | 31.4% |
| Innova | 120 of 382 | 31.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 7026YRACXJ12WHAAYORK · Y800with ductless indoor unit YRAKXJ12PHAA | York | 1 ton12,500 Btu/h · Non-ducted | 2.12 | 122% | 11.5 | 25.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218037193 |
| 7027YRACXJ12WHBAYORK · Y800with ductless indoor unit YRAKXJ12PHBA | York | 1 ton12,500 Btu/h · Non-ducted | 2.10 | 78% | 11.5 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218694512 |
| 7028YRACXJ18WHAAYORK · Y800with ductless indoor unit YRAKXJ18PHAA | York | 1.5 tons18,000 Btu/h · Non-ducted | 1.98 | 128% | 11.5 | 21.5 | CEE 25CEE 26XcelES CC | 1 | 218037194 |
| 7029YRACXJ18WHBAYORK · Y800with ductless indoor unit YRAKXJ18PHBA | York | 1.5 tons18,000 Btu/h · Non-ducted | 1.98 | 128% | 11.5 | 21.5 | CEE 25CEE 26XcelES CC | 1 | 218452759 |
| 7030YRACXJ24WHAAYORK · Y800with ductless indoor unit YRAKXJ24PHAA | York | 2 tons24,000 Btu/h · Non-ducted | 1.98 | 113% | 11.0 | 21.0 | CEE 25CEE 26Xcel | 1 | 218037195 |
| 7031YRACXJ24WHBAYORK · Y800with ductless indoor unit YRAKXJ24PHBA | York | 2 tons22,000 Btu/h · Non-ducted | 1.98 | 123% | 11.0 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 218452761 |
| 7032YRAMG24N3HAAYORK · MJ Multi-Split | York | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 77% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218014981 |
| 7033YRAMG24N3HBAYORK · MJ Multi-Split | York | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 77% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218362367 |
| 7034YRAMX18N2HBAYORK · MH MULTI-SPLIT | York | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 96% | 10.5 | 20.5 | CEE 25CEE 26XcelES CC | 3 | 218441894 |
| 7035YRAMX24N3HBAYORK · MH MULTI-SPLIT | York | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 9.3 | 17.0 | CEE 25CEE 26XcelES CC | 3 | 218636212 |
| 7036YRAMX36N4HAAYORK · MH MULTI-SPLIT | York | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 97% | 10.5 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218029791 |
| 7037YRAMX36N4HBAYORK · MH MULTI-SPLIT | York | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 93% | 10.0 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218788009 |
| 7038YRAMX42N5HBAYORK · MH MULTI-SPLIT | York | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.80 | 89% | 10.5 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 218080472 |
| 7039A7201P-9KZAFROwith ductless indoor unit A7201S-9K | zafro | 1 ton9,100 Btu/h · Non-ducted | 1.95 | 80% | 9.0 | 20.5 | CEE 25CEE 26Xcel | 1 | 217022881 |
| 7040A7201PW-9KZAFROwith ductless indoor unit A7201SW-9K | zafro | 1 ton9,100 Btu/h · Non-ducted | 1.95 | 80% | 9.0 | 20.5 | CEE 25CEE 26Xcel | 1 | 217022882 |
| 7041A7202P-12KZAFROwith ductless indoor unit A7202S-12K | zafro | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 74% | 8.3 | 18.5 | Xcel | 1 | 217022886 |
| 7042A7202P-18KZAFROwith ductless indoor unit A7202S-18K | zafro | 1.5 tons18,000 Btu/h · Non-ducted | 2.09 | 70% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 217022888 |
| 7043A7202P-9KZAFROwith ductless indoor unit A7202S-9K | zafro | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 98% | 8.0 | 18.5 | Xcel | 1 | 217022883 |
| 7044A7202PW-12KZAFROwith ductless indoor unit A7202SW-12K | zafro | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 74% | 8.3 | 18.5 | Xcel | 1 | 217022887 |
| 7045A7202PW-18KZAFROwith ductless indoor unit A7202SW-18K | zafro | 1.5 tons18,000 Btu/h · Non-ducted | 2.09 | 70% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 217022889 |
| 7046SE7203P-9Kzafrowith ductless indoor unit SE7203S-9K | zafro | 1 ton9,100 Btu/h · Non-ducted | 1.95 | 80% | 9.0 | 20.5 | CEE 25CEE 26Xcel | 1 | 218787910 |
| 7047SE7203P-9K-ASZzafrowith ductless indoor unit SE7203S-9K-ASZ | zafro | 1 ton9,100 Btu/h · Non-ducted | 1.95 | 80% | 9.0 | 20.5 | CEE 25CEE 26Xcel | 1 | 218787911 |
| 7048SE7203PW-18K-ZAZzafrowith ductless indoor unit SE7203SW-18K-ZAZ | zafro | 1.5 tons18,000 Btu/h · Non-ducted | 2.09 | 70% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 218080477 |
| 7049SE7203PW-9K-ZAZzafrowith ductless indoor unit SE7203SW-9K-ZAZ | zafro | 1 ton9,100 Btu/h · Non-ducted | 1.95 | 80% | 9.0 | 20.5 | CEE 25CEE 26Xcel | 1 | 218080468 |
| 7050SE7203S-18Kzafrowith ductless indoor unit SE7203P-18K | zafro | 1.5 tons18,000 Btu/h · Non-ducted | 2.09 | 70% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 218787914 |