Both views use the same certified data. This device remembers your choice.
Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
Simple view, for homeowners: top picks by size and what each rating measures →
Xcel EnergyData as of updated · sources
- Share of models
- 52.7%
- Qualifying models
- 7,174
- Qualifying certifications
- 197,833
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.7% · 3,292 of 5,427
- 2 tons59.4% · 1,152 of 1,941
- 2.5 to 3 tons50.4% · 1,483 of 2,942
- 3.5 to 4.5 tons42.2% · 1,195 of 2,834
- 5 tons and up10.9% · 52 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.7% · 3,292 of 5,427 |
| 2 tons | 59.4% · 1,152 of 1,941 |
| 2.5 to 3 tons | 50.4% · 1,483 of 2,942 |
| 3.5 to 4.5 tons | 42.2% · 1,195 of 2,834 |
| 5 tons and up | 10.9% · 52 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.2% | 2,070 / 6,438 |
| Non-ducted | 61.3% | 2,978 / 4,861 |
| Ducted and non-ducted | 91.6% | 2,126 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 387 of 555 | 69.7% |
| Carrier | 246 of 846 | 29.1% |
| TCL | 138 of 192 | 71.9% |
| BlueRidge | 132 of 194 | 68% |
| Daikin | 125 of 410 | 30.5% |
| AUX | 124 of 189 | 65.6% |
| Lennox | 121 of 341 | 35.5% |
| Ephoca | 120 of 382 | 31.4% |
| Innova | 120 of 382 | 31.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1201D5CURAH24AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**AL | Carrier | 2 tons24,800 Btu/h · Ducted | 2.14 | 82% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 2,378 | 218498234 |
| 1202D5CURAH30AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDR | Carrier | 2 tons26,600 Btu/h · Ducted | 2.21 | 66% | 7.5 | 15.2 | CEE 25CEE 26Xcel | 2,962 | 217906674 |
| 1203D5CURAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDR | Carrier | 3 tons33,200 Btu/h · Ducted | 2.54 | 72% | 8.1 | 14.5 | CEE 25CEE 26XcelES CC | 2,804 | 217906675 |
| 1204D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0D | Carrier | 4 tons47,500 Btu/h · Ducted | 1.86 | 81% | 8.0 | 15.5 | CEE 25CEE 26XcelES CC | 650 | 216772706 |
| 1205D5CVRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAK | Carrier | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 70% | 9.7 | 19.0 | CEE 25CEE 26XcelES CC | 18 | 215324155 |
| 1206D5CVRAH24AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH24XAK | Carrier | 2 tons24,000 Btu/h · Non-ducted | 2.01 | 71% | 8.5 | 17.0 | XcelES CC | 18 | 215324158 |
| 1207H5H0V24*K*AAA*HEILwith indoor coil D(A,C,E)37A3J+TDR and furnace *80CSU0401712B | Carrier | 2 tons23,000 Btu/h · Ducted | 2.76 | 94% | 8.5 | 16.5 | CEE 25CEE 26XcelES CC | 1,284 | 218372590 |
| 1208H5H0V36*K*AAA*HEILwith indoor coil D(A,C,E)37A3J+TDR and furnace *80CSU1002120A | Carrier | 2.5 tons31,000 Btu/h · Ducted | 2.44 | 100% | 8.5 | 17.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2,559 | 218372649 |
| 1209H5H0V48*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A | Carrier | 3.5 tons43,000 Btu/h · Ducted | 2.70 | 103% | 9.0 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,250 | 218372714 |
| 1210H5H3V36*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122B | Carrier | 3 tons35,600 Btu/h · Ducted | 2.14 | 75% | 9.0 | 22.0 | CEE 25CEE 26XcelES CC | 1,841 | 215936666 |
| 1211H5H3V48*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120A | Carrier | 3.5 tons43,500 Btu/h · Ducted | 2.00 | 76% | 9.5 | 20.5 | CEE 25CEE 26XcelES CC | 1,025 | 215933976 |
| 1212H5H3V60*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716B | Carrier | 4.5 tons56,000 Btu/h · Ducted | 2.10 | 75% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 549 | 215931656 |
| 1213H5H6S24*K*AAA*HEILwith indoor coil D(A,C,E)37A3J+TDR and furnace *96MSN0802120A | Carrier | 2 tons21,800 Btu/h · Ducted | 2.76 | 72% | 7.5 | 14.8 | CEE 25CEE 26Xcel | 4,031 | 218372090 |
| 1214HH824E2S11KENMOREwith ducted air handler JHC24B5AC2SS1 | Carrier | 2 tons24,000 Btu/h · Ducted | 2.10 | 71% | 9.5 | 19.0 | CEE 25CEE 26Xcel | 26 | 216591132 |
| 1215HH824E2S11*KENMORE · LX SERIESwith ducted air handler JHC24B5AC2SS1 | Carrier | 2 tons24,000 Btu/h · Ducted | 2.10 | 71% | 9.5 | 19.0 | CEE 25CEE 26Xcel | 177 | 216941336 |
| 1216HH824E2S12KENMORE · LX SERIESwith ducted air handler CTF36B5ADS2+JMC12B2SN1 | Carrier | 2 tons23,400 Btu/h · Ducted | 2.46 | 77% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 173 | 218642886 |
| 1217HH836E2S11KENMOREwith ducted air handler JHC36C5CD2SS1 | Carrier | 3 tons34,000 Btu/h · Ducted | 2.10 | 78% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 83 | 216591626 |
| 1218HH836E2S11*KENMORE · LX SERIESwith ducted air handler JHE42C5CF2SS2 | Carrier | 3 tons35,200 Btu/h · Ducted | 2.16 | 77% | 9.3 | 20.0 | CEE 25CEE 26Xcel | 512 | 218821666 |
| 1219HH836E2S12KENMORE · LX SERIESwith ducted air handler CTF48C5CFS2+JMC16C2SN1 | Carrier | 3 tons34,000 Btu/h · Ducted | 2.38 | 79% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 399 | 218643279 |
| 1220HH860E2S11KENMOREwith ducted air handler CTF60D5CGS1+JME18D2SN1 | Carrier | 4 tons46,000 Btu/h · Ducted | 2.00 | 74% | 9.5 | 19.0 | CEE 25CEE 26Xcel | 62 | 216591042 |
| 1221HH860E2S11*KENMORE · LX SERIESwith ducted air handler JHE48D5CG2SS2 | Carrier | 4 tons45,000 Btu/h · Ducted | 2.24 | 75% | 9.0 | 18.5 | CEE 25CEE 26Xcel | 331 | 218821670 |
| 1222HH860E2S12KENMORE · LX SERIESwith ducted air handler CTF60D5CGS2+JME18D2SN2 | Carrier | 4 tons46,000 Btu/h · Ducted | 2.32 | 77% | 8.5 | 17.5 | CEE 25CEE 26Xcel | 405 | 218642261 |
| 1223MCY-MUB0368HS2P-ULTOSHIBA CARRIER · MCY-MUB0368HS2P-UL | Carrier | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.42 | 71% | 12.1 | 29.1 | CEE 25CEE 26XcelES CC | 7 | 216760287 |
| 1224MCY-MUB0488HS2P-ULTOSHIBA CARRIER · MCY-MUB0488HS2P-UL | Carrier | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.50 | 70% | 11.3 | 24.4 | CEE 25CEE 26XcelES CC | 7 | 216760288 |
| 1225MCY-MUB0608HS2P-ULTOSHIBA CARRIER · Toshiba Miniwith ducted air handler MMD-UB0601VHN-UL | Carrier | 4.5 tons54,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.25 | 59% | 9.3 | 15.3 | CEE 25CEE 26Xcel | 5 | 218066442 |