Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
52.7%
Qualifying models
7,174
Qualifying certifications
197,833
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%64% of rated models reach 70% on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.1At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons60.7% · 3,292 of 5,427
2 tons59.4% · 1,152 of 1,941
2.5 to 3 tons50.4% · 1,483 of 2,942
3.5 to 4.5 tons42.2% · 1,195 of 2,834
5 tons and up10.9% · 52 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.2%2,070 / 6,438
Non-ducted61.3%2,978 / 4,861
Ducted and non-ducted91.6%2,126 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea387 of 55569.7%
Carrier246 of 84629.1%
TCL138 of 19271.9%
BlueRidge132 of 19468%
Daikin125 of 41030.5%
AUX124 of 18965.6%
Lennox121 of 34135.5%
Ephoca120 of 38231.4%
Innova120 of 38231.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 51 of 287
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1251W5H8V24AKAAAGrandaire · W5H Serieswith ducted air handler WCVL245CBCarrier2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC3218853990
1252W5H8V36AKAAAGrandaire · W5H Serieswith ducted air handler WCVL365CCCarrier3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC3218853992
1253W5H8V48AKAAAGrandaire · W5H Serieswith ducted air handler WCVL605CDCarrier4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC3218853993
1254W5H9V18AKAAAGrandaire · W5H Serieswith ducted air handler W5HM24X14EACarrier1.5 tons18,000 Btu/h · Ducted2.0695%9.516.1CEE 25CEE 26XcelES CC3218853995
1255W5H9V24AKAAAGrandaire · W5H Serieswith ducted air handler WCVL245CBCarrier2 tons23,000 Btu/h · Ducted1.8790%10.018.3CEE 25CEE 26XcelES CC10218160676
1256W5H9V30AKAAAGrandaire · W5H Serieswith ducted air handler WCVL305CBCarrier2.5 tons30,000 Btu/h · Ducted1.9696%10.016.8CEE 25CEE 26XcelES CC4218160682
1257W5H9V36AKAAAGrandaire · W5H Serieswith ducted air handler WCVL365CCCarrier3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC20218160677
1258W5H9V48AKAAAGrandaire · W5H Serieswith ducted air handler WCVL485CDCarrier4 tons48,000 Btu/h · Ducted1.9092%9.516.5CEE 25CEE 26XcelES CC13218160678
1259W5H9V60AKAAAGrandaire · W5H Serieswith ducted air handler W5HM60X24EACarrier4 tons47,000 Btu/h · Ducted1.8374%8.115.2CEE 25CEE 26XcelES CC7218214197
1260W5HD109J1E1AGrandaire · W5H Serieswith ductless indoor unit W5CSR09J1AAACarrier1 ton9,000 Btu/h · Non-ducted1.9570%9.021.5CEE 25CEE 26XcelES CC1218854011
1261W5HD109K1E1AGrandaire · W5H Serieswith ductless indoor unit W5CSR09K1AAACarrier1 ton9,000 Btu/h · Non-ducted1.9970%9.421.6CEE 25CEE 26XcelES CC1218854013
1262W5HD124K1E1AGrandaire · W5H Serieswith ductless indoor unit W5CSR24K1AAACarrier2 tons24,000 Btu/h · Non-ducted2.1171%9.018.5XcelES CC1218854016
1263W5HD606K1X1AGrandaire · W5H Serieswith ducted air handler W5GLW06K1AAACarrier0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC3218854029
1264W5HD609K1X1AGrandaire · W5H Serieswith ducted air handler W5GLW09K1AAACarrier1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.4CEE 25CEE 26XcelES CC6218854030
1265W5HD612K1X1AGrandaire · W5H Serieswith ductless indoor unit W5GCR12K1AAACarrier1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.2CEE 25CEE 26XcelES CC6218854026
1266W5HD618K1X1AGrandaire · W5H Serieswith ducted air handler W5GVW18J1AAACarrier1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.018.0CEE 25CEE 26XcelES CC8218853984
1267W5HD624K1X1AGrandaire · W5H Serieswith ductless indoor unit W5BSR24K1AAACarrier2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.0CEE 25CEE 26XcelES CC5218854023
1268W5HD633K1X1AGrandaire · W5H Serieswith ductless indoor unit W5BSR33K1AAACarrier3 tons33,000 Btu/h · Non-ducted1.9897%10.519.5CEE 25CEE 26XcelES CC1218854024
1269W5HDM18K1E3AGrandaire · W5H SeriesCarrier1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC3218854048
1270W5HDM18K1X3AGrandaire · W5H SeriesCarrier1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.0CEE 25CEE 26XcelES CC3218854061
1271W5HDM27K1E4AGrandaire · W5H SeriesCarrier2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.0CEE 25CEE 26XcelES CC3218854049
1272W5HDM27K1X4AGrandaire · W5H SeriesCarrier2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.0CEE 25CEE 26XcelES CC3218854064
1273W5HDM36K1E5AGrandaire · W5H SeriesCarrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.0CEE 25CEE 26XcelES CC3218854052
1274W5HDM36K1X5AGrandaire · W5H SeriesCarrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.0CEE 25CEE 26XcelES CC3218854067
1275W5HDM48K1E6AGrandaire · W5H SeriesCarrier4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.4CEE 25CEE 26XcelES CC3218854056

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter