Skip to content

ApooDr vs Kepler heat pumps

Measured against models of the same size and duct type, Kepler scores higher on 4 of the 6 ratings. ApooDr has 44 outdoor models, Kepler has 45 outdoor models. ApooDr and Kepler have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ApooDr and Kepler on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Kepler scores higher on 4 of the 6 ratings.
  • ApooDr
  • Kepler
  • Other ranked manufacturers
ApooDrKepler

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingApooDrKepler
Efficiency index59%median —63%median —
COP at 5°F64% (higher)median 2.0159% (higher)median 2.00
Capacity retention at 5°F46%median 71%63%median 81%
HSPF266%median 9.674%median 9.7
SEER265%median 20.165%median 20.0
EER255%median 12.058%median 11.7
Heating capacity at 5°F53%median 17,950 Btu/h65%median 21,600 Btu/h
Outdoor models4445
AHRI certifications61169

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardApooDrKepler
CEE 2025 Tier 1 (Split ASHP)90.9%40 models86.7%39 models
CEE 2026 Tier 1 (Split ASHP)86.4%38 models84.4%38 models
CEE Advanced Tier (Split ASHP)0%0 models2.2%1 models
Xcel Energy Colorado cold-climate ASHP (2025)75%33 models80%36 models
DOE Cold Climate Heat Pump Challenge0%0 models2.2%1 models
ENERGY STAR Cold Climate77.3%34 models75.6%34 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • ApooDr
  • Kepler
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeApooDrKepler
Ducted, up to 1.5 tons5 · index 71%11 · index 76%
Ducted, 2 tons4 · index 67%5 · index 67%
Ducted, 2.5 to 3 tons6 · index 61%9 · index 60%
Ducted, 3.5 to 4.5 tons7 · index 64%10 · index 59%
Ducted, 5 tons and up2 · index 65%1 · index 63%
Non-ducted, up to 1.5 tons19 · index 60%14 · index 64%
Non-ducted, 2 tons5 · index 53%3 · index 67%
Non-ducted, 2.5 to 3 tons4 · index 43%8 · index 53%
Non-ducted, 3.5 to 4.5 tons2 · index 43%4 · index 60%
Non-ducted, 5 tons and up1 · index 27%1 · index 59%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeApooDrCold-climate score, best modelKeplerCold-climate score, best model
Ducted, up to 1.5 tons81.7(50 is the typical model of its size class)ALC24-09H1Bwith ducted air handler DIU-09HWFN104 of 5 models qualify · AHRI 21756349293.7(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D10 of 11 models qualify · AHRI 218857674
Ducted, 2 tons77.1(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models qualify · AHRI 21756349585.8(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1Xwith ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models qualify · AHRI 218857661
Ducted, 2.5 to 3 tons77.7(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A4 of 6 models qualify · AHRI 21756347583.5(50 is the typical model of its size class) (higher)ODUMOX630-36HFN10-M2Xwith ducted air handler IDUMTJ-36HWFN10-M2-D8 of 9 models qualify · AHRI 218856688
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class)AM6OG-48HFN17 of 7 models qualify · AHRI 21756351582.6(50 is the typical model of its size class) (higher)ODUM6OE31-48HFN10-M1XD-D10 of 10 models qualify · AHRI 218853768
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons85.7(50 is the typical model of its size class)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A15 of 19 models qualify · AHRI 21756348897.0(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D11 of 14 models qualify · AHRI 218851004
Non-ducted, 2 tons75.9(50 is the typical model of its size class)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models qualify · AHRI 21756350290.1(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1Xwith ductless indoor unit IDUMCD-24HRFN10-M1-D3 of 3 models qualify · AHRI 218857649
Non-ducted, 2.5 to 3 tons63.6(50 is the typical model of its size class)ALC24-36H1Bwith ductless indoor unit CCA22-36HRFN12 of 4 models qualify · AHRI 21756350378.3(50 is the typical model of its size class) (higher)ODUM5OX631-36HFN10-M1XD-D6 of 8 models qualify · AHRI 218853766
Non-ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models qualify · AHRI 21756351673.6(50 is the typical model of its size class) (higher)ODUM6OE31-48HFN10-M1XD-D4 of 4 models qualify · AHRI 218853769
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeApooDrAll-around score, best modelKeplerAll-around score, best model
Ducted, up to 1.5 tons81.3(50 is the typical model of its size class)ALC24-09H1Bwith ducted air handler DIU-09HWFN105 of 5 models have all five ratings · AHRI 21756349295.1(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D11 of 11 models have all five ratings · AHRI 218857674
Ducted, 2 tons78.9(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models have all five ratings · AHRI 21756349578.9(50 is the typical model of its size class)ODUMOD30-24HFN10-M1with ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models have all five ratings · AHRI 218857656
Ducted, 2.5 to 3 tons75.1(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A6 of 6 models have all five ratings · AHRI 21756347583.9(50 is the typical model of its size class) (higher)ODUM5OX631-36HFN10-M1XD-D9 of 9 models have all five ratings · AHRI 218853765
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)AM6OG-48HFN17 of 7 models have all five ratings · AHRI 21756351585.3(50 is the typical model of its size class)ODUM6OE30-48HFN10-M1D-D10 of 10 models have all five ratings · AHRI 218853753
Ducted, 5 tons and up65.9(50 is the typical model of its size class) (higher)ALC24-60H1Bwith ducted air handler DIU-60HWFN102 of 2 models have all five ratings · AHRI 21756349863.2(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853756
Non-ducted, up to 1.5 tons86.7(50 is the typical model of its size class)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A19 of 19 models have all five ratings · AHRI 21756348896.6(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D14 of 14 models have all five ratings · AHRI 218851004
Non-ducted, 2 tons68.9(50 is the typical model of its size class)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models have all five ratings · AHRI 21756350287.8(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1with ductless indoor unit IDUMSEPD-24HRFN10-M1-D3 of 3 models have all five ratings · AHRI 218851003
Non-ducted, 2.5 to 3 tons59.3(50 is the typical model of its size class)AM5OG-36HFN14 of 4 models have all five ratings · AHRI 21756351178.8(50 is the typical model of its size class) (higher)ODUM5OX631-36HFN10-M1XD-D8 of 8 models have all five ratings · AHRI 218853764
Non-ducted, 3.5 to 4.5 tons53.1(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models have all five ratings · AHRI 21756351675.4(50 is the typical model of its size class) (higher)ODUM6OE31-48HFN10-M1XD-D4 of 4 models have all five ratings · AHRI 218853767
Non-ducted, 5 tons and up32.9(50 is the typical model of its size class)AM6OG-55HFN11 of 1 models have all five ratings · AHRI 21756351759.0(50 is the typical model of its size class) (higher)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853755

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingApooDrKepler
COP at 5°Fbeats 99% · 2.51ALC24-12H1BNon-ducted, up to 1.5 tonsbeats 99% · 2.51ODUMOX230-12HFN10-M1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 94% · 100%AHU3G-48HFN-BDucted, 3.5 to 4.5 tonsbeats 98% · 126%ODUMOX330-09HFN10-M1XNon-ducted, up to 1.5 tons
HSPF2beats 98% · 10.8AHU3G-30HFN-BDucted, 2.5 to 3 tonsbeats 99% · 14.8ODUMOX230-06HFN10-M1XNon-ducted, up to 1.5 tons
SEER2beats 96% · 20.4AM6OG-48HFN1Ducted, 3.5 to 4.5 tonsbeats 97% · 25.0ODUM4OD30-27HFN10-M1D-DNon-ducted, 2.5 to 3 tons
EER2beats 91% · 13.3ALC24-18H1BDucted, up to 1.5 tonsbeats 99% · 18.0ODUMOX230-06HFN10-M1XNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hAHU3G-50HFN-BAlso listed as AHU3G-60HFN-BDucted, 3.5 to 4.5 tonsbeats 98% · 39,000 Btu/hODUMOX630-36HFN10-M3XDucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
ApooDr vs Kepler: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • ApooDr (median, middle 50%)
  • Kepler (median, middle 50%)
Heating capacity, % of its 47°F maximum63%71%COP at maximum capacity2.012.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
ApooDr: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ApooDr, 47°F44100%100%100%100%100%
ApooDr, 17°F4465%67%72%74%80%
ApooDr, 5°F4457%59%63%67%82%
ApooDr: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ApooDr, 47°F442.772.983.163.473.69
ApooDr, 17°F442.122.22.272.462.59
ApooDr, 5°F441.841.932.012.152.3
Kepler: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Kepler, 47°F45100%100%100%100%100%
Kepler, 17°F4569%73%76%81%86%
Kepler, 5°F4559%64%71%79%82%
Kepler: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Kepler, 47°F452.843.063.23.463.72
Kepler, 17°F4522.142.322.512.61
Kepler, 5°F451.851.922.12.36

Source: NEEP ccASHP list · as of