Skip to content

BlueRidge vs Carrier heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings. BlueRidge has 192 outdoor models, Carrier has 816 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and Carrier on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings.
  • BlueRidge
  • Carrier
  • Other ranked manufacturers
BlueRidgeCarrier

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeCarrier
Efficiency index56% (higher)median — · 9th ranked48% (higher)median — · 23rd ranked
COP at 5°F57% (higher)median 2.00 · 14th ranked56% (higher)median 2.04 · 16th ranked
Capacity retention at 5°F55% (higher)median 74% · 12th ranked34% (higher)median 53% · 28th ranked
HSPF260% (higher)median 9.5 · 9th ranked40% (higher)median 7.8 · 25th ranked
SEER258% (higher)median 19.0 · 10th ranked42% (higher)median 15.2 · 23rd ranked
EER254%median 11.9 · 14th ranked59%median 11.5 · 8th ranked
Heating capacity at 5°F57% (higher)median 19,000 Btu/h · 12th ranked37% (higher)median 18,600 Btu/h · 27th ranked
Outdoor models192816
AHRI certifications1,622521,403

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeCarrier
CEE 2025 Tier 1 (Split ASHP)75.5%145 models40.2%328 models
CEE 2026 Tier 1 (Split ASHP)73.4%141 models35.3%288 models
CEE Advanced Tier (Split ASHP)3.6%7 models1%8 models
Xcel Energy Colorado cold-climate ASHP (2025)68.2%131 models27.2%222 models
DOE Cold Climate Heat Pump Challenge3.6%7 models1%8 models
ENERGY STAR Cold Climate64.6%124 models26.7%218 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • BlueRidge
  • Carrier
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeCarrier
Ducted, up to 1.5 tons29 · index 70%69 · index 56%
Ducted, 2 tons21 · index 59%93 · index 47%
Ducted, 2.5–3 tons37 · index 56%228 · index 45%
Ducted, 3.5–4.5 tons37 · index 60%306 · index 44%
Ducted, 5 tons and up5 · index 63%68 · index 50%
Non-ducted, up to 1.5 tons72 · index 54%54 · index 59%
Non-ducted, 2 tons17 · index 49%16 · index 57%
Non-ducted, 2.5–3 tons26 · index 50%30 · index 55%
Non-ducted, 3.5–4.5 tons20 · index 47%22 · index 47%
Non-ducted, 5 tons and up2 · index 59%4 · index 57%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelCarrierCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 21585393893.5(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK30 of 68 models qualify · AHRI 215323798
Ducted, 2 tons85.7(50 is the typical model of its size class)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC017 of 21 models qualify · AHRI 21585394585.7(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK44 of 94 models qualify · AHRI 215323817
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC022 of 37 models qualify · AHRI 21585396183.2(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK59 of 229 models qualify · AHRI 215357119
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN30 of 37 models qualify · AHRI 21799260789.7(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A63 of 293 models qualify · AHRI 218372714
Ducted, 5 tons and upNone on this board (0 of 5 models qualify)94.7(50 is the typical model of its size class)MCY-MUB0608HS2P-UL19 of 80 models qualify · AHRI 216763249
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC052 of 72 models qualify · AHRI 21585390196.8(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK35 of 54 models qualify · AHRI 215413214
Non-ducted, 2 tons89.4(50 is the typical model of its size class)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 21585393389.4(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK15 of 16 models qualify · AHRI 215323815
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 21585396489.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK21 of 30 models qualify · AHRI 215323843
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 21585399079.4(50 is the typical model of its size class) (higher)RAV-BP421AT2P-ULwith ductless indoor unit RAV-HB421CTP-UL18 of 22 models qualify · AHRI 216415472
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)50.6(50 is the typical model of its size class)37VMB060HDS3-11 of 4 models qualify · AHRI 216369714

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelCarrierAll-around score, best model
Ducted, up to 1.5 tons95.0(50 is the typical model of its size class)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 21585393895.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK64 of 68 models have all five ratings · AHRI 215323798
Ducted, 2 tons78.8(50 is the typical model of its size class)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC021 of 21 models have all five ratings · AHRI 21585392482.9(50 is the typical model of its size class) (higher)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA90 of 90 models have all five ratings · AHRI 217624252
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC036 of 36 models have all five ratings · AHRI 21585398688.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL209 of 230 models have all five ratings · AHRI 216415477
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC038 of 38 models have all five ratings · AHRI 21585397790.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA241 of 275 models have all five ratings · AHRI 215587917
Ducted, 5 tons and up66.7(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 21637190989.1(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA81 of 101 models have all five ratings · AHRI 215931484
Non-ducted, up to 1.5 tons96.2(50 is the typical model of its size class)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC070 of 72 models have all five ratings · AHRI 21585390196.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK51 of 54 models have all five ratings · AHRI 215323742
Non-ducted, 2 tons86.8(50 is the typical model of its size class)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 21585390088.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK15 of 16 models have all five ratings · AHRI 215323752
Non-ducted, 2.5–3 tons78.3(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 21585398591.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL29 of 30 models have all five ratings · AHRI 216415465
Non-ducted, 3.5–4.5 tons75.6(50 is the typical model of its size class)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 21585398884.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL20 of 22 models have all five ratings · AHRI 216760288
Non-ducted, 5 tons and up58.6(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 21585399469.0(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL4 of 4 models have all five ratings · AHRI 216763251

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeCarrier
COP at 5°Fbeats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tonsbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5–4.5 tons
Capacity retention at 5°Fbeats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tons
HSPF2beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tons
SEER2beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tons
EER2beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tonsbeats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tonsbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5–4.5 tons

More comparisons