Both views use the same certified data. This device remembers your choice.
BlueRidge vs Carrier heat pumps
Measured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings. BlueRidge has 194 outdoor models, Carrier has 846 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BlueRidge
- Carrier
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BlueRidge | Carrier |
|---|---|---|
| Efficiency index | 57% (higher)median — · 10th ranked | 49% (higher)median — · 23rd ranked |
| COP at 5°F | 57%median 2.00 · 13th ranked | 57%median 2.04 · 15th ranked |
| Capacity retention at 5°F | 55% (higher)median 74% · 12th ranked | 36% (higher)median 55% · 28th ranked |
| HSPF2 | 60% (higher)median 9.5 · 9th ranked | 41% (higher)median 7.8 · 24th ranked |
| SEER2 | 58% (higher)median 19.0 · 9th ranked | 43% (higher)median 15.3 · 23rd ranked |
| EER2 | 54%median 11.9 · 15th ranked | 60%median 11.5 · 8th ranked |
| Heating capacity at 5°F | 57% (higher)median 19,000 Btu/h · 11th ranked | 39% (higher)median 18,600 Btu/h · 27th ranked |
| Outdoor models | 194 | 846 |
| AHRI certifications | 1,700 | 589,089 |
Share of models meeting each standard
| Standard | BlueRidge | Carrier |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 75.3%146 models | 41.8%354 models |
| CEE 2026 Tier 1 (Split ASHP) | 73.2%142 models | 37%313 models |
| CEE Advanced Tier (Split ASHP) | 3.6%7 models | 1.1%9 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 68%132 models | 29.1%246 models |
| DOE Cold Climate Heat Pump Challenge | 3.6%7 models | 1.1%9 models |
| ENERGY STAR Cold Climate | 64.4%125 models | 27.4%232 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BlueRidge
- Carrier
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BlueRidge | Carrier |
|---|---|---|
| Ducted, up to 1.5 tons | 29 · index 70% | 76 · index 59% |
| Ducted, 2 tons | 21 · index 59% | 99 · index 47% |
| Ducted, 2.5 to 3 tons | 38 · index 56% | 232 · index 46% |
| Ducted, 3.5 to 4.5 tons | 36 · index 60% | 311 · index 45% |
| Ducted, 5 tons and up | 5 · index 64% | 69 · index 51% |
| Non-ducted, up to 1.5 tons | 74 · index 55% | 65 · index 60% |
| Non-ducted, 2 tons | 17 · index 51% | 18 · index 58% |
| Non-ducted, 2.5 to 3 tons | 26 · index 51% | 37 · index 56% |
| Non-ducted, 3.5 to 4.5 tons | 20 · index 47% | 25 · index 50% |
| Non-ducted, 5 tons and up | 2 · index 59% | 5 · index 58% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BlueRidgeCold-climate score, best model | CarrierCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 215853938 | 93.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK35 of 75 models qualify · AHRI 215323798 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC018 of 22 models qualify · AHRI 215853945 | 85.8(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK49 of 99 models qualify · AHRI 215323817 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC022 of 37 models qualify · AHRI 215853961 | 83.6(50 is the typical model of its size class) (higher)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK65 of 235 models qualify · AHRI 215357119 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 217992607 | 89.5(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A67 of 297 models qualify · AHRI 218372714 |
| Ducted, 5 tons and up | None on this board (0 of 5 models qualify) | 94.8(50 is the typical model of its size class)MCY-MUB0608HS2P-UL19 of 81 models qualify · AHRI 216763249 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 215853901 | 97.1(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK42 of 65 models qualify · AHRI 215413214 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 215853933 | 90.1(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK17 of 18 models qualify · AHRI 215323815 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 215853964 | 89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK26 of 37 models qualify · AHRI 215323843 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 215853990 | 75.6(50 is the typical model of its size class) (higher)37MGHAQ48FA3Also sold as Arcoaire D5CMHAH48FAK19 of 25 models qualify · AHRI 215357123 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 52.1(50 is the typical model of its size class)37VMB060HDS3-11 of 5 models qualify · AHRI 216369714 |
All-around best
| Size and duct type | BlueRidgeAll-around score, best model | CarrierAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 95.1(50 is the typical model of its size class)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 215853938 | 95.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK70 of 75 models have all five ratings · AHRI 215323798 |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC021 of 21 models have all five ratings · AHRI 215853924 | 82.8(50 is the typical model of its size class) (higher)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA93 of 93 models have all five ratings · AHRI 217624252 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC037 of 37 models have all five ratings · AHRI 215853986 | 88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL216 of 237 models have all five ratings · AHRI 216415477 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 215853977 | 90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA245 of 280 models have all five ratings · AHRI 215587917 |
| Ducted, 5 tons and up | 67.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371909 | 89.3(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA82 of 102 models have all five ratings · AHRI 215931484 |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 215853901 | 96.9(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK61 of 65 models have all five ratings · AHRI 215323742 |
| Non-ducted, 2 tons | 87.8(50 is the typical model of its size class)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 215853900 | 89.4(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK17 of 18 models have all five ratings · AHRI 215323752 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 215853985 | 91.1(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL36 of 37 models have all five ratings · AHRI 216415465 |
| Non-ducted, 3.5 to 4.5 tons | 75.4(50 is the typical model of its size class)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 215853988 | 84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL21 of 25 models have all five ratings · AHRI 216760288 |
| Non-ducted, 5 tons and up | 59.0(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 215853994 | 69.5(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL5 of 5 models have all five ratings · AHRI 216763251 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BlueRidge | Carrier |
|---|---|---|
| COP at 5°F | beats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tons | beats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons | beats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tons |
| HSPF2 | beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons | beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tons |
| SEER2 | beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons | beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tons |
| EER2 | beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tons | beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tons | beats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5 to 4.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- BlueRidge (median, middle 50%)
- Carrier (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BlueRidge, 47°F | 175 | 100% | 100% | 100% | 100% | 100% |
| BlueRidge, 17°F | 175 | 64% | 68% | 74% | 82% | 88% |
| BlueRidge, 5°F | 175 | 57% | 60% | 66% | 78% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BlueRidge, 47°F | 175 | 2.88 | 3.07 | 3.23 | 3.47 | 3.59 |
| BlueRidge, 17°F | 175 | 2.03 | 2.19 | 2.33 | 2.41 | 2.61 |
| BlueRidge, 5°F | 175 | 1.83 | 1.96 | 2 | 2.14 | 2.31 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Carrier, 47°F | 256 | 100% | 100% | 100% | 100% | 100% |
| Carrier, 17°F | 256 | 65% | 71% | 78% | 85% | 91% |
| Carrier, 5°F | 256 | 57% | 62% | 70% | 78% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Carrier, 47°F | 256 | 2.87 | 3.09 | 3.23 | 3.52 | 3.63 |
| Carrier, 17°F | 256 | 2.12 | 2.24 | 2.38 | 2.52 | 2.65 |
| Carrier, 5°F | 256 | 1.85 | 1.99 | 2.02 | 2.15 | 2.32 |
Source: NEEP ccASHP list · as of