BOREAL vs HITACHI heat pumps
Measured against models of the same size and duct type, HITACHI scores higher on 5 of the 6 ratings. BOREAL has 50 outdoor models, HITACHI has 66 outdoor models. BOREAL and HITACHI have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BOREAL
- HITACHI
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BOREAL | HITACHI |
|---|---|---|
| Efficiency index | 53%median — | 67%median — |
| COP at 5°F | 43%median 1.95 | 65%median 2.10 |
| Capacity retention at 5°F | 59%median 78% | 62%median 79% |
| HSPF2 | 41%median 9.0 | 73%median 10.5 |
| SEER2 | 59%median 19.0 | 59%median 21.0 |
| EER2 | 56%median 11.9 | 75%median 12.9 |
| Heating capacity at 5°F | 57%median 17,000 Btu/h | 65%median 18,750 Btu/h |
| Outdoor models | 50 | 66 |
| AHRI certifications | 145 | 172 |
Share of models meeting each standard
| Standard | BOREAL | HITACHI |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 86%43 models | 97%64 models |
| CEE 2026 Tier 1 (Split ASHP) | 86%43 models | 97%64 models |
| CEE Advanced Tier (Split ASHP) | 6%3 models | 16.7%11 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 88%44 models | 84.8%56 models |
| DOE Cold Climate Heat Pump Challenge | 6%3 models | 16.7%11 models |
| ENERGY STAR Cold Climate | 60%30 models | 80.3%53 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BOREAL
- HITACHI
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BOREAL | HITACHI |
|---|---|---|
| Ducted, up to 1.5 tons | 9 · index 65% | 11 · index 68% |
| Ducted, 2 tons | 6 · index 58% | 6 · index 70% |
| Ducted, 2.5 to 3 tons | 12 · index 53% | 11 · index 74% |
| Ducted, 3.5 to 4.5 tons | 6 · index 68% | 7 · index 68% |
| Non-ducted, up to 1.5 tons | 23 · index 47% | 34 · index 68% |
| Non-ducted, 2 tons | 6 · index 50% | 12 · index 69% |
| Non-ducted, 2.5 to 3 tons | 6 · index 43% | 13 · index 57% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 39% | 6 · index 57% |
| Non-ducted, 5 tons and up | None | 1 · index 54% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BOREALCold-climate score, best model | HITACHICold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.7(50 is the typical model of its size class)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA8 of 9 models qualify · AHRI 215560267 | 80.8(50 is the typical model of its size class) (higher)PAS-18BLFASDQ1with ducted air handler PPIM-B18UFA1DQ9 of 11 models qualify · AHRI 215222822 |
| Ducted, 2 tons | 76.3(50 is the typical model of its size class) (higher)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 7 models qualify · AHRI 215420685 | 75.6(50 is the typical model of its size class)PAS-24BLFASDQ1with ducted air handler PPIM-B24UFA1DQ6 of 6 models qualify · AHRI 215222823 |
| Ducted, 2.5 to 3 tons | 77.3(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH7 of 11 models qualify · AHRI 217463586 | 87.4(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ9 of 11 models qualify · AHRI 213685840 |
| Ducted, 3.5 to 4.5 tons | 85.1(50 is the typical model of its size class) (higher)ENX60HPJ132OAwith ducted air handler ENX60HPJ132IA5 of 6 models qualify · AHRI 215420683 | 72.8(50 is the typical model of its size class)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ3 of 7 models qualify · AHRI 213685842 |
| Non-ducted, up to 1.5 tons | 64.7(50 is the typical model of its size class)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA21 of 23 models qualify · AHRI 215424783 | 92.4(50 is the typical model of its size class) (higher)PAS-18BLFASDQ1with ductless indoor unit PCI-B18UFA1DQ32 of 34 models qualify · AHRI 215222824 |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)MUL24HPJ132OA5 of 6 models qualify · AHRI 215424769 | 97.0(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models qualify · AHRI 215222825 |
| Non-ducted, 2.5 to 3 tons | 77.8(50 is the typical model of its size class)MUL36HPJ132OA6 of 6 models qualify · AHRI 215424771 | 97.3(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ductless indoor unit PCI-B30UFA1DQ9 of 13 models qualify · AHRI 215222826 |
| Non-ducted, 3.5 to 4.5 tons | 67.0(50 is the typical model of its size class) (higher)MUL42HPJ132OA2 of 2 models qualify · AHRI 215424772 | 59.5(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PPFC-B48UFA1DQ3 of 6 models qualify · AHRI 214779302 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | BOREALAll-around score, best model | HITACHIAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 84.0(50 is the typical model of its size class) (higher)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA9 of 9 models have all five ratings · AHRI 215560267 | 80.7(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ11 of 11 models have all five ratings · AHRI 215359321 |
| Ducted, 2 tons | 68.6(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 6 models have all five ratings · AHRI 215420685 | 80.2(50 is the typical model of its size class) (higher)PAS-24BUFASDQ1-LACwith ducted air handler PPIM-B24UFA1DQ6 of 6 models have all five ratings · AHRI 217450753 |
| Ducted, 2.5 to 3 tons | 68.5(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH12 of 12 models have all five ratings · AHRI 217463586 | 91.3(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ11 of 11 models have all five ratings · AHRI 213685840 |
| Ducted, 3.5 to 4.5 tons | 80.0(50 is the typical model of its size class)ENX48HPJ132OAwith ducted air handler ENX48HPJ132IAAlso listed as ENX60HPJ132OA, ARX60HPJ1R32OA6 of 6 models have all five ratings · AHRI 215420684 | 83.4(50 is the typical model of its size class) (higher)PAS-48BUFASDQ1-LACwith ducted air handler PPIM-B48UFA1DQ7 of 7 models have all five ratings · AHRI 217450756 |
| Non-ducted, up to 1.5 tons | 79.8(50 is the typical model of its size class)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA23 of 23 models have all five ratings · AHRI 215424783 | 90.1(50 is the typical model of its size class) (higher)RAC-XJ12WHAAwith ductless indoor unit RAK-XJ12PHAA34 of 34 models have all five ratings · AHRI 215911631 |
| Non-ducted, 2 tons | 73.1(50 is the typical model of its size class)KUL24HPJ132OAwith ductless indoor unit KUL24HPJ132IA5 of 6 models have all five ratings · AHRI 215424817 | 85.7(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models have all five ratings · AHRI 215222825 |
| Non-ducted, 2.5 to 3 tons | 71.2(50 is the typical model of its size class)MUL30HPJ132OA6 of 6 models have all five ratings · AHRI 215424770 | 85.2(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ductless indoor unit PCI-B30UFA1DQ13 of 13 models have all five ratings · AHRI 214723260 |
| Non-ducted, 3.5 to 4.5 tons | 67.8(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models have all five ratings · AHRI 215424772 | 70.2(50 is the typical model of its size class) (higher)PAS-48BUFASDQ1-LACwith ductless indoor unit PCI-B48UFA1DQ6 of 6 models have all five ratings · AHRI 217450780 |
| Non-ducted, 5 tons and up | No models in this size class | 54.1(50 is the typical model of its size class)HVAHP060C23S*1 of 1 models have all five ratings · AHRI 217036518 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BOREAL | HITACHI |
|---|---|---|
| COP at 5°F | beats 87% · 2.10MUL36HPJ132OANon-ducted, 2.5 to 3 tons | beats 100% · 2.50PAS-30BUFASDQ1Non-ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 94% · 100%ENX60HPJ132OADucted, 3.5 to 4.5 tons | beats 100% · 147%RAC-XJ09WHAANon-ducted, up to 1.5 tons |
| HSPF2 | beats 91% · 10.5ENX60HPJ132OADucted, 3.5 to 4.5 tons | beats 100% · 12.0PAS-30BUFASDQ1Non-ducted, 2.5 to 3 tons |
| SEER2 | beats 99% · 22.5KUL18HPJ132OAAlso listed as NOV18HPJ132OADucted, up to 1.5 tons | beats 100% · 24.2HVAHP048C23S*Non-ducted, 3.5 to 4.5 tons |
| EER2 | beats 97% · 14.2KUL09HPJ132OAAlso listed as NOV09HPJ132OADucted, up to 1.5 tons | beats 100% · 16.8HVAHP036C23S*Non-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 54,000 Btu/hENX60HPJ132OADucted, 3.5 to 4.5 tons | beats 100% · 23,000 Btu/hRAC-XJ18WHAAAlso listed as RAC-XJ18WHBANon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- BOREAL (median, middle 50%)
- HITACHI (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BOREAL, 47°F | 45 | 100% | 100% | 100% | 100% | 100% |
| BOREAL, 17°F | 45 | 68% | 75% | 82% | 87% | 96% |
| BOREAL, 5°F | 45 | 59% | 63% | 69% | 76% | 96% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BOREAL, 47°F | 45 | 2.92 | 3.11 | 3.28 | 3.37 | 3.47 |
| BOREAL, 17°F | 45 | 2.06 | 2.1 | 2.3 | 2.4 | 2.57 |
| BOREAL, 5°F | 45 | 1.8 | 1.85 | 2 | 2.07 | 2.14 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HITACHI, 47°F | 45 | 100% | 100% | 100% | 100% | 100% |
| HITACHI, 17°F | 45 | 65% | 71% | 79% | 88% | 97% |
| HITACHI, 5°F | 45 | 58% | 65% | 75% | 80% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HITACHI, 47°F | 45 | 2.7 | 2.96 | 3.28 | 3.53 | 3.83 |
| HITACHI, 17°F | 45 | 2.15 | 2.2 | 2.3 | 2.61 | 2.86 |
| HITACHI, 5°F | 45 | 1.8 | 1.98 | 2.1 | 2.2 | 2.4 |
Source: NEEP ccASHP list · as of