Skip to content

BROCK vs Kerr heat pumps

Measured against models of the same size and duct type, Kerr scores higher on 5 of the 6 ratings. BROCK has 36 outdoor models, Kerr has 38 outdoor models. BROCK and Kerr have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BROCK and Kerr on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Kerr scores higher on 5 of the 6 ratings.
  • BROCK
  • Kerr
  • Other ranked manufacturers
BROCKKerr

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBROCKKerr
Efficiency index35%median —66%median —
COP at 5°F41%median 1.8059%median 2.00
Capacity retention at 5°F13%median 41%77%median 95%
HSPF224%median 6.778%median 10.0
SEER224%median 13.464%median 19.5
EER264% (higher)median 11.162% (higher)median 11.9
Heating capacity at 5°F17%median 17,000 Btu/h73%median 18,500 Btu/h
Outdoor models3638
AHRI certifications3,770113

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBROCKKerr
CEE 2025 Tier 1 (Split ASHP)19.4%7 models78.9%30 models
CEE 2026 Tier 1 (Split ASHP)11.1%4 models76.3%29 models
CEE Advanced Tier (Split ASHP)0%0 models2.6%1 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models89.5%34 models
DOE Cold Climate Heat Pump Challenge0%0 models2.6%1 models
ENERGY STAR Cold Climate0%0 models89.5%34 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • BROCK
  • Kerr
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBROCKKerr
Ducted, up to 1.5 tons2 · index 45%7 · index 75%
Ducted, 2 tons4 · index 35%3 · index 60%
Ducted, 2.5–3 tons11 · index 35%7 · index 66%
Ducted, 3.5–4.5 tons17 · index 31%5 · index 61%
Ducted, 5 tons and up2 · index 61%None
Non-ducted, up to 1.5 tonsNone18 · index 66%
Non-ducted, 2 tonsNone3 · index 58%
Non-ducted, 2.5–3 tonsNone3 · index 67%
Non-ducted, 3.5–4.5 tonsNone2 · index 67%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBROCKCold-climate score, best modelKerrCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)82.3(50 is the typical model of its size class)A-KHP18SA-1with ducted air handler B-KHP18DA-17 of 7 models qualify · AHRI 217482433
Ducted, 2 tonsNone on this board (0 of 4 models qualify)85.7(50 is the typical model of its size class)A-KHP24SA-1with ducted air handler B-KHP24DA-13 of 3 models qualify · AHRI 217482436
Ducted, 2.5–3 tonsNone on this board (0 of 11 models qualify)82.5(50 is the typical model of its size class)A-KHP365A-17 of 7 models qualify · AHRI 216097146
Ducted, 3.5–4.5 tonsNone on this board (0 of 17 models qualify)82.7(50 is the typical model of its size class)A-KHP486A-15 of 5 models qualify · AHRI 216097150
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class96.7(50 is the typical model of its size class)A-KHP06SA-1with ductless indoor unit B-KHP06SA-112 of 18 models qualify · AHRI 216097110
Non-ducted, 2 tonsNo models in this size class89.4(50 is the typical model of its size class)A-KHP24SA-1with ductless indoor unit B-KHP24CA-13 of 3 models qualify · AHRI 217482434
Non-ducted, 2.5–3 tonsNo models in this size class78.0(50 is the typical model of its size class)A-KHP365A-13 of 3 models qualify · AHRI 216097148
Non-ducted, 3.5–4.5 tonsNo models in this size class73.4(50 is the typical model of its size class)A-KHP486A-12 of 2 models qualify · AHRI 216097152

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBROCKAll-around score, best modelKerrAll-around score, best model
Ducted, up to 1.5 tons48.3(50 is the typical model of its size class)PH5SAN519**AA*with indoor coil CAA**1917AM and furnace PG92MSAA42060B2 of 2 models have all five ratings · AHRI 21770247486.5(50 is the typical model of its size class) (higher)A-KHP09SA-1with ducted air handler B-KHP09DA-17 of 7 models have all five ratings · AHRI 217482423
Ducted, 2 tons60.6(50 is the typical model of its size class)PH8TAN524**AA*with indoor coil CAA**3721AM and furnace PG80MSUA48060B4 of 4 models have all five ratings · AHRI 21564787678.4(50 is the typical model of its size class) (higher)A-KHP24SA-1with ducted air handler B-KHP24DA-13 of 3 models have all five ratings · AHRI 217482436
Ducted, 2.5–3 tons66.7(50 is the typical model of its size class)PH8TAN536**AA*with ducted air handler PF5TNBD60L11 of 11 models have all five ratings · AHRI 21562894883.6(50 is the typical model of its size class) (higher)A-KHP365A-17 of 7 models have all five ratings · AHRI 216097146
Ducted, 3.5–4.5 tons72.7(50 is the typical model of its size class)PH8TAN548**AA*with ducted air handler QFVA5D6021X16 of 16 models have all five ratings · AHRI 21869544483.9(50 is the typical model of its size class) (higher)A-KHP486A-15 of 5 models have all five ratings · AHRI 216097150
Ducted, 5 tons and up80.2(50 is the typical model of its size class)PH8TAN560**AA*with ducted air handler PF5TNBD60L3 of 3 models have all five ratings · AHRI 215560743No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class96.2(50 is the typical model of its size class)A-KHP06SA-1with ductless indoor unit B-KHP06SA-116 of 18 models have all five ratings · AHRI 216097110
Non-ducted, 2 tonsNo models in this size class76.4(50 is the typical model of its size class)A-KHP24SA-1with ductless indoor unit B-KHP24SA-1Also listed as A-ZKP24SA-13 of 3 models have all five ratings · AHRI 216097114
Non-ducted, 2.5–3 tonsNo models in this size class78.3(50 is the typical model of its size class)A-KHP365A-13 of 3 models have all five ratings · AHRI 216097145
Non-ducted, 3.5–4.5 tonsNo models in this size class75.6(50 is the typical model of its size class)A-KHP486A-12 of 2 models have all five ratings · AHRI 216097149

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBROCKKerr
COP at 5°Fbeats 92% · 2.48PH8TAN536**AA*Ducted, 2.5–3 tonsbeats 97% · 2.40A-KHP06SA-1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 41% · 52%PH5SAN560**AA*Also listed as PH5SAP560**AADucted, 5 tons and upbeats 100% · 150%A-KZP06SA-1Also listed as A-ZKP06SA-1Non-ducted, up to 1.5 tons
HSPF2beats 58% · 8.5PH8TAN548**AA*Ducted, 3.5–4.5 tonsbeats 100% · 15.6A-KZP06SA-1Also listed as A-ZKP06SA-1Non-ducted, up to 1.5 tons
SEER2beats 81% · 17.5PH8TAN560**AA*Ducted, 5 tons and upbeats 100% · 27.0A-ZKP15SA-1Ducted, up to 1.5 tons
EER2beats 99% · 13.5PH8TAN548**AA*Ducted, 3.5–4.5 tonsbeats 99% · 18.0A-KHP06SA-1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 44% · 8,600 Btu/hPH5SAN518**AA*Ducted, up to 1.5 tonsbeats 99% · 22,600 Btu/hA-KZP18SA-1Also listed as A-ZKP18SA-1Non-ducted, up to 1.5 tons

More comparisons