Skip to content

Carrier vs Fujitsu heat pumps

Measured against models of the same size and duct type, Fujitsu scores higher on 5 of the 6 ratings. Carrier has 846 outdoor models, Fujitsu has 180 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Fujitsu on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Fujitsu scores higher on 5 of the 6 ratings.
  • Carrier
  • Fujitsu
  • Other ranked manufacturers
CarrierFujitsu

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierFujitsu
Efficiency index49%median — · 23rd ranked53%median — · 16th ranked
COP at 5°F57%median 2.04 · 15th ranked58%median 2.08 · 12th ranked
Capacity retention at 5°F36%median 55% · 28th ranked48%median 54% · 20th ranked
HSPF241%median 7.8 · 24th ranked45%median 7.5 · 19th ranked
SEER243%median 15.3 · 23rd ranked44%median 15.2 · 22nd ranked
EER260% (higher)median 11.5 · 8th ranked48% (higher)median 11.0 · 18th ranked
Heating capacity at 5°F39%median 18,600 Btu/h · 27th ranked49%median 18,200 Btu/h · 17th ranked
Outdoor models846180
AHRI certifications589,0892,088

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierFujitsu
CEE 2025 Tier 1 (Split ASHP)41.8%354 models33.3%60 models
CEE 2026 Tier 1 (Split ASHP)37%313 models32.2%58 models
CEE Advanced Tier (Split ASHP)1.1%9 models7.8%14 models
Xcel Energy Colorado cold-climate ASHP (2025)29.1%246 models30%54 models
DOE Cold Climate Heat Pump Challenge1.1%9 models7.8%14 models
ENERGY STAR Cold Climate27.4%232 models28.9%52 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Carrier
  • Fujitsu
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierFujitsu
Ducted, up to 1.5 tons76 · index 59%12 · index 58%
Ducted, 2 tons99 · index 47%17 · index 38%
Ducted, 2.5 to 3 tons232 · index 46%44 · index 40%
Ducted, 3.5 to 4.5 tons311 · index 45%57 · index 44%
Ducted, 5 tons and up69 · index 51%22 · index 34%
Non-ducted, up to 1.5 tons65 · index 60%27 · index 76%
Non-ducted, 2 tons18 · index 58%8 · index 76%
Non-ducted, 2.5 to 3 tons37 · index 56%11 · index 69%
Non-ducted, 3.5 to 4.5 tons25 · index 50%9 · index 63%
Non-ducted, 5 tons and up5 · index 58%1 · index 79%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelFujitsuCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK35 of 75 models qualify · AHRI 21532379887.7(50 is the typical model of its size class)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 218814795
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK49 of 99 models qualify · AHRI 21532381783.6(50 is the typical model of its size class)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 218807602
Ducted, 2.5 to 3 tons83.6(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK65 of 235 models qualify · AHRI 21535711987.1(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 217895716
Ducted, 3.5 to 4.5 tons89.5(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A67 of 297 models qualify · AHRI 21837271480.9(50 is the typical model of its size class)FOP1948MJAYCAwith indoor coil FCCA4821SYEA and furnace FF80TV407517UH10 of 57 models qualify · AHRI 216687202
Ducted, 5 tons and up94.8(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 81 models qualify · AHRI 21676324972.3(50 is the typical model of its size class)AOUK060MSAN71 of 22 models qualify · AHRI 218467769
Non-ducted, up to 1.5 tons97.1(50 is the typical model of its size class)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK42 of 65 models qualify · AHRI 21541321498.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 216018255
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK17 of 18 models qualify · AHRI 21532381586.5(50 is the typical model of its size class)AOUH24KWAH36 of 8 models qualify · AHRI 215447693
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK26 of 37 models qualify · AHRI 21532384394.5(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 217895708
Non-ducted, 3.5 to 4.5 tons75.6(50 is the typical model of its size class)37MGHAQ48FA3Also sold as Arcoaire D5CMHAH48FAK19 of 25 models qualify · AHRI 21535712377.1(50 is the typical model of its size class) (higher)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models qualify · AHRI 217895710
Non-ducted, 5 tons and up52.1(50 is the typical model of its size class)37VMB060HDS3-11 of 5 models qualify · AHRI 21636971472.0(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 1 models qualify · AHRI 218466063

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelFujitsuAll-around score, best model
Ducted, up to 1.5 tons95.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK70 of 75 models have all five ratings · AHRI 21532379890.1(50 is the typical model of its size class)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 218814799
Ducted, 2 tons82.8(50 is the typical model of its size class)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA93 of 93 models have all five ratings · AHRI 21762425285.9(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 215447694
Ducted, 2.5 to 3 tons88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL216 of 237 models have all five ratings · AHRI 21641547786.3(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS31 of 44 models have all five ratings · AHRI 217895716
Ducted, 3.5 to 4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA245 of 280 models have all five ratings · AHRI 21558791785.6(50 is the typical model of its size class)AOUH42KUAH1with ducted air handler ARUH42KUAS32 of 53 models have all five ratings · AHRI 217895714
Ducted, 5 tons and up89.3(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA82 of 102 models have all five ratings · AHRI 21593148457.0(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA16 of 26 models have all five ratings · AHRI 215415496
Non-ducted, up to 1.5 tons96.9(50 is the typical model of its size class)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK61 of 65 models have all five ratings · AHRI 21532374299.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 216018255
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK17 of 18 models have all five ratings · AHRI 21532375288.5(50 is the typical model of its size class)AOUH24KWAH37 of 8 models have all five ratings · AHRI 215447693
Non-ducted, 2.5 to 3 tons91.1(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL36 of 37 models have all five ratings · AHRI 21641546590.1(50 is the typical model of its size class)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 217895708
Non-ducted, 3.5 to 4.5 tons84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL21 of 25 models have all five ratings · AHRI 21676028880.2(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS8 of 9 models have all five ratings · AHRI 217895710
Non-ducted, 5 tons and up69.5(50 is the typical model of its size class)MCY-MUB0608HS2P-UL5 of 5 models have all five ratings · AHRI 21676325178.9(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 1 models have all five ratings · AHRI 218466063

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierFujitsu
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5 to 4.5 tonsbeats 100% · 2.62AOUH12KTAP1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 102%AOUH42KUAH1Non-ducted, 3.5 to 4.5 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5 to 3 tonsbeats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5 to 4.5 tonsbeats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Carrier vs Fujitsu: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Carrier (median, middle 50%)
  • Fujitsu (median, middle 50%)
Heating capacity, % of its 47°F maximum70%73%COP at maximum capacity2.022.18

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Carrier: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F256100%100%100%100%100%
Carrier, 17°F25665%71%78%85%91%
Carrier, 5°F25657%62%70%78%82%
Carrier: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F2562.873.093.233.523.63
Carrier, 17°F2562.122.242.382.522.65
Carrier, 5°F2561.851.992.022.152.32
Fujitsu: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Fujitsu, 47°F59100%100%100%100%100%
Fujitsu, 17°F5965%71%82%90%95%
Fujitsu, 5°F5959%66%73%86%94%
Fujitsu: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Fujitsu, 47°F592.52.753.213.564.12
Fujitsu, 17°F592.282.322.42.62.72
Fujitsu, 5°F5922.12.182.32.41

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter