Skip to content

Carrier vs Fujitsu heat pumps

Measured against models of the same size and duct type, Fujitsu scores higher on 5 of the 6 ratings. Carrier has 816 outdoor models, Fujitsu has 179 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Fujitsu on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Fujitsu scores higher on 5 of the 6 ratings.
  • Carrier
  • Fujitsu
  • Other ranked manufacturers
CarrierFujitsu

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierFujitsu
Efficiency index48%median — · 23rd ranked53%median — · 16th ranked
COP at 5°F56%median 2.04 · 16th ranked60%median 2.10 · 8th ranked
Capacity retention at 5°F34%median 53% · 28th ranked48%median 56% · 19th ranked
HSPF240%median 7.8 · 25th ranked44%median 7.5 · 19th ranked
SEER242%median 15.2 · 23rd ranked43%median 15.2 · 22nd ranked
EER259% (higher)median 11.5 · 8th ranked47% (higher)median 11.0 · 19th ranked
Heating capacity at 5°F37%median 18,600 Btu/h · 27th ranked50%median 18,100 Btu/h · 17th ranked
Outdoor models816179
AHRI certifications521,4032,057

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierFujitsu
CEE 2025 Tier 1 (Split ASHP)40.2%328 models32.4%58 models
CEE 2026 Tier 1 (Split ASHP)35.3%288 models31.3%56 models
CEE Advanced Tier (Split ASHP)1%8 models7.8%14 models
Xcel Energy Colorado cold-climate ASHP (2025)27.2%222 models29.6%53 models
DOE Cold Climate Heat Pump Challenge1%8 models7.8%14 models
ENERGY STAR Cold Climate26.7%218 models26.8%48 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Carrier
  • Fujitsu
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierFujitsu
Ducted, up to 1.5 tons69 · index 56%12 · index 57%
Ducted, 2 tons93 · index 47%17 · index 37%
Ducted, 2.5–3 tons228 · index 45%44 · index 42%
Ducted, 3.5–4.5 tons306 · index 44%56 · index 44%
Ducted, 5 tons and up68 · index 50%22 · index 32%
Non-ducted, up to 1.5 tons54 · index 59%27 · index 75%
Non-ducted, 2 tons16 · index 57%8 · index 74%
Non-ducted, 2.5–3 tons30 · index 55%11 · index 68%
Non-ducted, 3.5–4.5 tons22 · index 47%8 · index 62%
Non-ducted, 5 tons and up4 · index 57%1 · index 78%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelFujitsuCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK30 of 68 models qualify · AHRI 21532379887.4(50 is the typical model of its size class)AOUH18KUAH1with ducted air handler ARUH18KUAS7 of 12 models qualify · AHRI 218814795
Ducted, 2 tons85.7(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK44 of 94 models qualify · AHRI 21532381783.4(50 is the typical model of its size class)AOUH24KUAH1with ducted air handler ARUH24KUAS5 of 17 models qualify · AHRI 218807602
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK59 of 229 models qualify · AHRI 21535711987.0(50 is the typical model of its size class) (higher)AOUH30KUAH1with ducted air handler AMUH30KUAS8 of 44 models qualify · AHRI 217895716
Ducted, 3.5–4.5 tons89.7(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A63 of 293 models qualify · AHRI 21837271479.3(50 is the typical model of its size class)AOUH42KUAS1with ducted air handler ARUH42KUAS9 of 56 models qualify · AHRI 215812202
Ducted, 5 tons and up94.7(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 80 models qualify · AHRI 21676324971.9(50 is the typical model of its size class)AOUK060MSAN71 of 22 models qualify · AHRI 218467769
Non-ducted, up to 1.5 tons96.8(50 is the typical model of its size class)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK35 of 54 models qualify · AHRI 21541321498.5(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS25 of 27 models qualify · AHRI 216018255
Non-ducted, 2 tons89.4(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK15 of 16 models qualify · AHRI 21532381593.1(50 is the typical model of its size class) (higher)AOUK024SSAN77 of 8 models qualify · AHRI 216372779
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK21 of 30 models qualify · AHRI 21532384394.6(50 is the typical model of its size class) (higher)AOUH30KUAH1with ductless indoor unit AUUH30KUAS9 of 11 models qualify · AHRI 217895708
Non-ducted, 3.5–4.5 tons79.4(50 is the typical model of its size class) (higher)RAV-BP421AT2P-ULwith ductless indoor unit RAV-HB421CTP-UL18 of 22 models qualify · AHRI 21641547276.7(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS7 of 8 models qualify · AHRI 217895710
Non-ducted, 5 tons and up50.6(50 is the typical model of its size class)37VMB060HDS3-11 of 4 models qualify · AHRI 21636971470.6(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 1 models qualify · AHRI 218466063

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelFujitsuAll-around score, best model
Ducted, up to 1.5 tons95.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK64 of 68 models have all five ratings · AHRI 21532379890.0(50 is the typical model of its size class)AOUH12KUBS1with ducted air handler ADUH12KUBS12 of 12 models have all five ratings · AHRI 218814799
Ducted, 2 tons82.9(50 is the typical model of its size class)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA90 of 90 models have all five ratings · AHRI 21762425285.7(50 is the typical model of its size class) (higher)AOUH24KWAH317 of 17 models have all five ratings · AHRI 215447694
Ducted, 2.5–3 tons88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL209 of 230 models have all five ratings · AHRI 21641547786.1(50 is the typical model of its size class)AOUH30KUAH1with ducted air handler AMUH30KUAS28 of 44 models have all five ratings · AHRI 217895716
Ducted, 3.5–4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA241 of 275 models have all five ratings · AHRI 21558791785.4(50 is the typical model of its size class)AOUH42KUAH1with ducted air handler ARUH42KUAS28 of 52 models have all five ratings · AHRI 217895714
Ducted, 5 tons and up89.1(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA81 of 101 models have all five ratings · AHRI 21593148456.6(50 is the typical model of its size class)WP15AY60AJ2Nwith ducted air handler FHRNTT6024S*YTNAAlso listed as FOP1560TJAYNA14 of 26 models have all five ratings · AHRI 215415496
Non-ducted, up to 1.5 tons96.5(50 is the typical model of its size class)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK51 of 54 models have all five ratings · AHRI 21532374299.1(50 is the typical model of its size class) (higher)AOUH09KTAP1with ductless indoor unit ASUH09KTAS27 of 27 models have all five ratings · AHRI 216018255
Non-ducted, 2 tons88.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK15 of 16 models have all five ratings · AHRI 21532375288.0(50 is the typical model of its size class)AOUK024SSAN78 of 8 models have all five ratings · AHRI 216372779
Non-ducted, 2.5–3 tons91.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL29 of 30 models have all five ratings · AHRI 21641546590.0(50 is the typical model of its size class)AOUH30KUAH1with ductless indoor unit AUUH30KUAS10 of 11 models have all five ratings · AHRI 217895708
Non-ducted, 3.5–4.5 tons84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL20 of 22 models have all five ratings · AHRI 21676028880.2(50 is the typical model of its size class)AOUH42KUAH1with ductless indoor unit AUUH42KUAS7 of 8 models have all five ratings · AHRI 217895710
Non-ducted, 5 tons and up69.0(50 is the typical model of its size class)MCY-MUB0608HS2P-UL4 of 4 models have all five ratings · AHRI 21676325177.9(50 is the typical model of its size class) (higher)AOUK060MSAN71 of 1 models have all five ratings · AHRI 218466063

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierFujitsu
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5–4.5 tonsbeats 100% · 3.03AOUK024SSAN7Non-ducted, 2 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 102%AOUH42KUAH1Non-ducted, 3.5–4.5 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 98% · 14.0AOUH09KTAP1Non-ducted, up to 1.5 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 33.5AOUH09KTAP1Non-ducted, up to 1.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5–3 tonsbeats 100% · 19.1AOUH09KTAP1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5–4.5 tonsbeats 100% · 25,400 Btu/hAOUH18KZAH1Non-ducted, up to 1.5 tons

More comparisons