HITACHI vs TEMP SHIFT heat pumps
Measured against models of the same size and duct type, HITACHI and TEMP SHIFT split the 6 ratings 3–3. HITACHI has 63 outdoor models, TEMP SHIFT has 19 outdoor models. HITACHI and TEMP SHIFT have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- HITACHI
- TEMP SHIFT
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | HITACHI | TEMP SHIFT |
|---|---|---|
| Efficiency index | 68% (higher)median — | 66% (higher)median — |
| COP at 5°F | 66% (higher)median 2.13 | 52% (higher)median 2.00 |
| Capacity retention at 5°F | 60%median 79% | 79%median 95% |
| HSPF2 | 70%median 10.0 | 79%median 10.2 |
| SEER2 | 63% (higher)median 21.8 | 61% (higher)median 19.4 |
| EER2 | 75% (higher)median 13.0 | 62% (higher)median 12.0 |
| Heating capacity at 5°F | 64%median 18,500 Btu/h | 76%median 24,000 Btu/h |
| Outdoor models | 63 | 19 |
| AHRI certifications | 164 | 51 |
Share of models meeting each standard
| Standard | HITACHI | TEMP SHIFT |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 95.2%60 models | 94.7%18 models |
| CEE 2026 Tier 1 (Split ASHP) | 95.2%60 models | 94.7%18 models |
| CEE Advanced Tier (Split ASHP) | 17.5%11 models | 5.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 82.5%52 models | 89.5%17 models |
| DOE Cold Climate Heat Pump Challenge | 17.5%11 models | 5.3%1 models |
| ENERGY STAR Cold Climate | 79.4%50 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- HITACHI
- TEMP SHIFT
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | HITACHI | TEMP SHIFT |
|---|---|---|
| Ducted, up to 1.5 tons | 10 · index 70% | 5 · index 76% |
| Ducted, 2 tons | 6 · index 71% | 2 · index 70% |
| Ducted, 2.5–3 tons | 11 · index 74% | 4 · index 73% |
| Ducted, 3.5–4.5 tons | 6 · index 70% | 4 · index 65% |
| Non-ducted, up to 1.5 tons | 33 · index 70% | 5 · index 74% |
| Non-ducted, 2 tons | 12 · index 67% | 1 · index 68% |
| Non-ducted, 2.5–3 tons | 12 · index 58% | 4 · index 44% |
| Non-ducted, 3.5–4.5 tons | 5 · index 58% | 3 · index 52% |
| Non-ducted, 5 tons and up | 1 · index 54% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | HITACHICold-climate score, best model | TEMP SHIFTCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 79.3(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ8 of 10 models qualify · AHRI 215359321 | 82.3(50 is the typical model of its size class) (higher)TSSZHH182R5with ducted air handler TSDT182R55 of 5 models qualify · AHRI 218426393 |
| Ducted, 2 tons | 75.5(50 is the typical model of its size class)PAS-24BLFASDQ1with ducted air handler PPIM-B24UFA1DQ6 of 6 models qualify · AHRI 215222823 | 85.7(50 is the typical model of its size class) (higher)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models qualify · AHRI 218426394 |
| Ducted, 2.5–3 tons | 83.7(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ducted air handler PPIM-B30UFA1DQ9 of 11 models qualify · AHRI 215222843 | 82.5(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models qualify · AHRI 218426402 |
| Ducted, 3.5–4.5 tons | 72.7(50 is the typical model of its size class)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ2 of 6 models qualify · AHRI 213685842 | 82.7(50 is the typical model of its size class) (higher)TSMZHH486Z2R54 of 4 models qualify · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | 91.6(50 is the typical model of its size class)PAS-18BLFASDQ1with ductless indoor unit PCI-B18UFA1DQ29 of 33 models qualify · AHRI 215222824 | 93.8(50 is the typical model of its size class) (higher)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models qualify · AHRI 218426379 |
| Non-ducted, 2 tons | 93.8(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models qualify · AHRI 215222825 | 89.4(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSCS242R51 of 1 models qualify · AHRI 218426389 |
| Non-ducted, 2.5–3 tons | 97.4(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ductless indoor unit PCI-B30UFA1DQ9 of 12 models qualify · AHRI 215222826 | 72.6(50 is the typical model of its size class)TSMZHH365Z2R52 of 4 models qualify · AHRI 218426403 |
| Non-ducted, 3.5–4.5 tons | 59.0(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PCI-B48UFA1DQ2 of 5 models qualify · AHRI 214723262 | 69.9(50 is the typical model of its size class) (higher)TSMZHH556Z2R53 of 3 models qualify · AHRI 218426409 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | HITACHIAll-around score, best model | TEMP SHIFTAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.9(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ10 of 10 models have all five ratings · AHRI 215359321 | 86.5(50 is the typical model of its size class) (higher)TSSZHH092R5with ducted air handler TSDT092R55 of 5 models have all five ratings · AHRI 218426391 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class) (higher)PAS-24BUFASDQ1-LACwith ducted air handler PPIM-B24UFA1DQ6 of 6 models have all five ratings · AHRI 217450753 | 78.4(50 is the typical model of its size class)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models have all five ratings · AHRI 218426394 |
| Ducted, 2.5–3 tons | 90.1(50 is the typical model of its size class) (higher)PAS-36BLFASDQ1with ducted air handler PPIM-B36UFA1DQ11 of 11 models have all five ratings · AHRI 215222841 | 83.6(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426402 |
| Ducted, 3.5–4.5 tons | 85.7(50 is the typical model of its size class) (higher)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ6 of 6 models have all five ratings · AHRI 213685842 | 83.9(50 is the typical model of its size class)TSMZHH486Z2R54 of 4 models have all five ratings · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | 90.5(50 is the typical model of its size class)PAS-12BLFASDQ1with ductless indoor unit PCIM-B12UFA1DQ31 of 33 models have all five ratings · AHRI 215359322 | 93.8(50 is the typical model of its size class) (higher)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models have all five ratings · AHRI 218426379 |
| Non-ducted, 2 tons | 81.6(50 is the typical model of its size class) (higher)PAS-24BUFASDQ1-LACwith ductless indoor unit PCI-B24UFA1DQ12 of 12 models have all five ratings · AHRI 217450777 | 72.9(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSHW242R51 of 1 models have all five ratings · AHRI 218426383 |
| Non-ducted, 2.5–3 tons | 93.9(50 is the typical model of its size class) (higher)PAS-36BLFASDQ1with ductless indoor unit PCI-B36UFA1DQ12 of 12 models have all five ratings · AHRI 215222842 | 66.3(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426401 |
| Non-ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class) (higher)PAS-48BUFASDQ1with ductless indoor unit PCI-B48UFA1DQ5 of 5 models have all five ratings · AHRI 214723262 | 62.6(50 is the typical model of its size class)TSMZHH556Z2R53 of 3 models have all five ratings · AHRI 218426407 |
| Non-ducted, 5 tons and up | 54.1(50 is the typical model of its size class)HVAHP060C23S*1 of 1 models have all five ratings · AHRI 217036518 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | HITACHI | TEMP SHIFT |
|---|---|---|
| COP at 5°F | beats 100% · 2.50PAS-30BUFASDQ1Non-ducted, 2.5–3 tons | beats 91% · 2.29TSSZHH062R5Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 123%RAC-XJ24WHBANon-ducted, 2 tons | beats 98% · 120%TSSZHH092R5Ducted, up to 1.5 tons |
| HSPF2 | beats 98% · 11.0RAM-X36N4HAADucted, 2.5–3 tons | beats 99% · 11.0TSMZHH486Z2R5Ducted, 3.5–4.5 tons |
| SEER2 | beats 100% · 24.2HVAHP048C23S*Non-ducted, 3.5–4.5 tons | beats 96% · 20.4TSMZHH486Z2R5Ducted, 3.5–4.5 tons |
| EER2 | beats 100% · 16.8HVAHP036C23S*Non-ducted, 2.5–3 tons | beats 96% · 16.0TSSZHH062R5Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 23,000 Btu/hRAC-XJ18WHAAAlso listed as RAC-XJ18WHBANon-ducted, up to 1.5 tons | beats 97% · 39,000 Btu/hTSHCHH362R5Ducted, 2.5–3 tons |