HITACHI vs TEMP SHIFT heat pumps
Measured against models of the same size and duct type, TEMP SHIFT scores higher on 4 of the 6 ratings. HITACHI has 66 outdoor models, TEMP SHIFT has 19 outdoor models. HITACHI and TEMP SHIFT have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- HITACHI
- TEMP SHIFT
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | HITACHI | TEMP SHIFT |
|---|---|---|
| Efficiency index | 67%median — | 67%median — |
| COP at 5°F | 65% (higher)median 2.10 | 52% (higher)median 2.00 |
| Capacity retention at 5°F | 62%median 79% | 80%median 95% |
| HSPF2 | 73%median 10.5 | 80%median 10.2 |
| SEER2 | 59%median 21.0 | 61%median 19.4 |
| EER2 | 75% (higher)median 12.9 | 64% (higher)median 12.0 |
| Heating capacity at 5°F | 65%median 18,750 Btu/h | 77%median 24,000 Btu/h |
| Outdoor models | 66 | 19 |
| AHRI certifications | 172 | 51 |
Share of models meeting each standard
| Standard | HITACHI | TEMP SHIFT |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 97%64 models | 94.7%18 models |
| CEE 2026 Tier 1 (Split ASHP) | 97%64 models | 94.7%18 models |
| CEE Advanced Tier (Split ASHP) | 16.7%11 models | 5.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 84.8%56 models | 89.5%17 models |
| DOE Cold Climate Heat Pump Challenge | 16.7%11 models | 5.3%1 models |
| ENERGY STAR Cold Climate | 80.3%53 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- HITACHI
- TEMP SHIFT
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | HITACHI | TEMP SHIFT |
|---|---|---|
| Ducted, up to 1.5 tons | 11 · index 68% | 5 · index 77% |
| Ducted, 2 tons | 6 · index 70% | 2 · index 70% |
| Ducted, 2.5 to 3 tons | 11 · index 74% | 4 · index 73% |
| Ducted, 3.5 to 4.5 tons | 7 · index 68% | 4 · index 66% |
| Non-ducted, up to 1.5 tons | 34 · index 68% | 5 · index 76% |
| Non-ducted, 2 tons | 12 · index 69% | 1 · index 71% |
| Non-ducted, 2.5 to 3 tons | 13 · index 57% | 4 · index 45% |
| Non-ducted, 3.5 to 4.5 tons | 6 · index 57% | 3 · index 52% |
| Non-ducted, 5 tons and up | 1 · index 54% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | HITACHICold-climate score, best model | TEMP SHIFTCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 80.8(50 is the typical model of its size class)PAS-18BLFASDQ1with ducted air handler PPIM-B18UFA1DQ9 of 11 models qualify · AHRI 215222822 | 82.9(50 is the typical model of its size class) (higher)TSSZHH182R5with ducted air handler TSDT182R55 of 5 models qualify · AHRI 218426393 |
| Ducted, 2 tons | 75.6(50 is the typical model of its size class)PAS-24BLFASDQ1with ducted air handler PPIM-B24UFA1DQ6 of 6 models qualify · AHRI 215222823 | 85.8(50 is the typical model of its size class) (higher)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models qualify · AHRI 218426394 |
| Ducted, 2.5 to 3 tons | 87.4(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ9 of 11 models qualify · AHRI 213685840 | 82.7(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models qualify · AHRI 218426402 |
| Ducted, 3.5 to 4.5 tons | 72.8(50 is the typical model of its size class)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ3 of 7 models qualify · AHRI 213685842 | 82.6(50 is the typical model of its size class) (higher)TSMZHH486Z2R54 of 4 models qualify · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | 92.4(50 is the typical model of its size class)PAS-18BLFASDQ1with ductless indoor unit PCI-B18UFA1DQ32 of 34 models qualify · AHRI 215222824 | 94.5(50 is the typical model of its size class) (higher)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models qualify · AHRI 218426379 |
| Non-ducted, 2 tons | 97.0(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models qualify · AHRI 215222825 | 90.1(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSCS242R51 of 1 models qualify · AHRI 218426389 |
| Non-ducted, 2.5 to 3 tons | 97.3(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ductless indoor unit PCI-B30UFA1DQ9 of 13 models qualify · AHRI 215222826 | 72.8(50 is the typical model of its size class)TSMZHH365Z2R52 of 4 models qualify · AHRI 218426403 |
| Non-ducted, 3.5 to 4.5 tons | 59.5(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PPFC-B48UFA1DQ3 of 6 models qualify · AHRI 214779302 | 70.3(50 is the typical model of its size class) (higher)TSMZHH556Z2R53 of 3 models qualify · AHRI 218426409 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | HITACHIAll-around score, best model | TEMP SHIFTAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 80.7(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ11 of 11 models have all five ratings · AHRI 215359321 | 87.0(50 is the typical model of its size class) (higher)TSSZHH092R5with ducted air handler TSDT092R55 of 5 models have all five ratings · AHRI 218426391 |
| Ducted, 2 tons | 80.2(50 is the typical model of its size class) (higher)PAS-24BUFASDQ1-LACwith ducted air handler PPIM-B24UFA1DQ6 of 6 models have all five ratings · AHRI 217450753 | 78.6(50 is the typical model of its size class)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models have all five ratings · AHRI 218426394 |
| Ducted, 2.5 to 3 tons | 91.3(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ11 of 11 models have all five ratings · AHRI 213685840 | 83.9(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426402 |
| Ducted, 3.5 to 4.5 tons | 83.4(50 is the typical model of its size class)PAS-48BUFASDQ1-LACwith ducted air handler PPIM-B48UFA1DQ7 of 7 models have all five ratings · AHRI 217450756 | 84.3(50 is the typical model of its size class) (higher)TSMZHH486Z2R54 of 4 models have all five ratings · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | 90.1(50 is the typical model of its size class)RAC-XJ12WHAAwith ductless indoor unit RAK-XJ12PHAA34 of 34 models have all five ratings · AHRI 215911631 | 94.5(50 is the typical model of its size class) (higher)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models have all five ratings · AHRI 218426379 |
| Non-ducted, 2 tons | 85.7(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models have all five ratings · AHRI 215222825 | 74.3(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSHW242R51 of 1 models have all five ratings · AHRI 218426383 |
| Non-ducted, 2.5 to 3 tons | 85.2(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ductless indoor unit PCI-B30UFA1DQ13 of 13 models have all five ratings · AHRI 214723260 | 67.0(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426401 |
| Non-ducted, 3.5 to 4.5 tons | 70.2(50 is the typical model of its size class) (higher)PAS-48BUFASDQ1-LACwith ductless indoor unit PCI-B48UFA1DQ6 of 6 models have all five ratings · AHRI 217450780 | 62.6(50 is the typical model of its size class)TSMZHH556Z2R53 of 3 models have all five ratings · AHRI 218426407 |
| Non-ducted, 5 tons and up | 54.1(50 is the typical model of its size class)HVAHP060C23S*1 of 1 models have all five ratings · AHRI 217036518 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | HITACHI | TEMP SHIFT |
|---|---|---|
| COP at 5°F | beats 100% · 2.50PAS-30BUFASDQ1Non-ducted, 2.5 to 3 tons | beats 92% · 2.29TSSZHH062R5Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 147%RAC-XJ09WHAANon-ducted, up to 1.5 tons | beats 98% · 120%TSSZHH092R5Ducted, up to 1.5 tons |
| HSPF2 | beats 100% · 12.0PAS-30BUFASDQ1Non-ducted, 2.5 to 3 tons | beats 99% · 11.0TSMZHH486Z2R5Ducted, 3.5 to 4.5 tons |
| SEER2 | beats 100% · 24.2HVAHP048C23S*Non-ducted, 3.5 to 4.5 tons | beats 96% · 20.4TSMZHH486Z2R5Ducted, 3.5 to 4.5 tons |
| EER2 | beats 100% · 16.8HVAHP036C23S*Non-ducted, 2.5 to 3 tons | beats 96% · 16.0TSSZHH062R5Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 23,000 Btu/hRAC-XJ18WHAAAlso listed as RAC-XJ18WHBANon-ducted, up to 1.5 tons | beats 98% · 39,000 Btu/hTSHCHH362R5Ducted, 2.5 to 3 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- HITACHI (median, middle 50%)
- TEMP SHIFT (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HITACHI, 47°F | 45 | 100% | 100% | 100% | 100% | 100% |
| HITACHI, 17°F | 45 | 65% | 71% | 79% | 88% | 97% |
| HITACHI, 5°F | 45 | 58% | 65% | 75% | 80% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HITACHI, 47°F | 45 | 2.7 | 2.96 | 3.28 | 3.53 | 3.83 |
| HITACHI, 17°F | 45 | 2.15 | 2.2 | 2.3 | 2.61 | 2.86 |
| HITACHI, 5°F | 45 | 1.8 | 1.98 | 2.1 | 2.2 | 2.4 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TEMP SHIFT, 47°F | 19 | 100% | 100% | 100% | 100% | 100% |
| TEMP SHIFT, 17°F | 19 | 66% | 75% | 81% | 84% | 88% |
| TEMP SHIFT, 5°F | 19 | 68% | 71% | 78% | 81% | 84% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TEMP SHIFT, 47°F | 19 | 2.67 | 3.04 | 3.23 | 3.55 | 3.64 |
| TEMP SHIFT, 17°F | 19 | 2 | 2.09 | 2.24 | 2.4 | 2.52 |
| TEMP SHIFT, 5°F | 19 | 1.87 | 1.92 | 2 | 2.04 | 2.13 |
Source: NEEP ccASHP list · as of