Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.1%
- Qualifying models
- 7,036
- Qualifying certifications
- 221,680
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,238 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 519 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,401 |
| 75 to under 80% | 1,156 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 720 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,111 |
| 7.8 to under 8.0 | 381 |
| 8.0 to under 8.3 | 723 |
| 8.3 to under 8.5 | 178 |
| 8.5 to under 8.8 | 1,451 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,500 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,371 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,002 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,101 |
| 15.5 to under 16.0 | 284 |
| 16.0 to under 16.5 | 624 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 849 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 680 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 917 |
| 20.5 to under 21.0 | 162 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 18 |
| 27.0 to under 27.5 | 60 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 95 |
| 8.5 to under 9.0 | 214 |
| 9.0 to under 9.5 | 702 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 881 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,678 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,869 |
| 12.5 to under 13.0 | 951 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 274 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 179 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons62.1% · 2,928 of 4,715
- 2 tons67.6% · 1,181 of 1,748
- 2.5–3 tons57.3% · 1,560 of 2,724
- 3.5–4.5 tons45.5% · 1,222 of 2,687
- 5 tons and up31.7% · 145 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 62.1% · 2,928 of 4,715 |
| 2 tons | 67.6% · 1,181 of 1,748 |
| 2.5–3 tons | 57.3% · 1,560 of 2,724 |
| 3.5–4.5 tons | 45.5% · 1,222 of 2,687 |
| 5 tons and up | 31.7% · 145 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.5% | 2,089 / 6,056 |
| Non-ducted | 69% | 2,820 / 4,087 |
| Ducted and non-ducted | 97.2% | 2,127 / 2,189 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 580 of 717 | 80.9% |
| Midea | 412 of 546 | 75.5% |
| Carrier | 328 of 816 | 40.2% |
| Daikin | 150 of 394 | 38.1% |
| Lennox | 147 of 337 | 43.6% |
| BlueRidge | 145 of 192 | 75.5% |
| Trane | 140 of 363 | 38.6% |
| TCL | 134 of 177 | 75.7% |
| Hisense | 129 of 161 | 80.1% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 3776KEENHYMHP12AAKEEN Home · KEEN Serieswith ductless indoor unit KEENHYMAH612A | KEEN Home | 0.5 tons6,000 Btu/h · Non-ducted | 2.00 | 150% | 15.6 | 35.0 | CEE 25CEE 26Xcel | 1 | 217596897 |
| 3777KEENHYZHP20AAKEEN Home · KEEN Series | KEEN Home | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 217596922 |
| 3778KEENHYZHP27AAKEEN Home · KEEN Series | KEEN Home | 2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 9.5 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 217596926 |
| 3779KEENHYZHP36AAKEEN Home · KEEN Series | KEEN Home | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 106% | 10.4 | 19.4 | CEE 25CEE 26XcelES CC | 3 | 217596929 |
| 3780KEENHYZHP49AAKEEN Home · KEEN Series | KEEN Home | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 98% | 10.2 | 21.2 | CEE 25CEE 26XcelES CC | 3 | 217596931 |
| 3781KEENHYZHP55AAKEEN Home · KEEN Series | KEEN Home | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217596935 |
| 3782KEENSTDHP18AAKEEN Home · KEEN Serieswith ducted air handler KEENHYDAH18AA | KEEN Home | 1.5 tons18,000 Btu/h · Ducted | 2.00 | 62% | 9.1 | 18.8 | CEE 25CEE 26 | 2 | 217596872 |
| 3783KEENSTDHP24AAKEEN Home · KEEN Serieswith ducted air handler KEENHYDAH24AA | KEEN Home | 2 tons24,000 Btu/h · Ducted | 1.87 | 83% | 9.7 | 18.1 | CEE 25CEE 26XcelES CC | 2 | 217596873 |
| 3784KEENSTDHP36AAKEEN Home · KEEN Serieswith ducted air handler KEENHYDAH36AA | KEEN Home | 3 tons36,000 Btu/h · Ducted | 2.00 | 75% | 8.7 | 16.1 | CEE 25CEE 26XcelES CC | 2 | 217596874 |
| 3785KEENSTDHP48AAKEEN Home · KEEN Serieswith ducted air handler KEENHYDAH48AA | KEEN Home | 4 tons48,000 Btu/h · Ducted | 1.85 | 79% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 1 | 217596875 |
| 3786KEENSTMHP09AAKEEN Home · KEEN Serieswith ductless indoor unit KEENSTMAH09AA | KEEN Home | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 96% | 12.5 | 26.0 | CEE 25CEE 26XcelES CC | 1 | 217596892 |
| 3787KEENSTMHP12AAKEEN Home · KEEN Serieswith ductless indoor unit KEENSTMAH12AA | KEEN Home | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 96% | 10.5 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217596893 |
| 3788KEENSTMHP18AAKEEN Home · KEEN Serieswith ductless indoor unit KEENSTMAH18AA | KEEN Home | 1.5 tons18,000 Btu/h · Non-ducted | 2.00 | 100% | 10.8 | 21.7 | CEE 25CEE 26XcelES CC | 1 | 217596894 |
| 3789KEENSTZHP19AAKEEN Home · KEEN Series | KEEN Home | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.30 | 77% | 10.0 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217596908 |
| 3790KEENSTZHP27AAKEEN Home · KEEN Series | KEEN Home | 2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 217596910 |
| 3791KEENSTZHP37AAKEEN Home · KEEN Series | KEEN Home | 3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 10.0 | 23.1 | CEE 25CEE 26XcelES CC | 3 | 217596913 |
| 3792KEENSTZHP48AAKEEN Home · KEEN Series | KEEN Home | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 75% | 10.0 | 21.3 | CEE 25CEE 26XcelES CC | 3 | 217596916 |
| 3793KEENSTZHP60AAKEEN Home | KEEN Home | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 67% | 9.2 | 18.0 | CEE 25CEE 26 | 3 | 217596920 |
| 3794KEENULDHP36AAKEEN Home · KEEN Serieswith ducted air handler KEENULDAH36AA | KEEN Home | 3 tons36,000 Btu/h · Ducted | 2.06 | 91% | 10.0 | 17.7 | CEE 25CEE 26XcelES CC | 1 | 217596883 |
| 3795KEENUMHP06AAKEEN Home · KEEN Serieswith ductless indoor unit KEENOWAH06AA | KEEN Home | 0.5 tons6,500 Btu/h · Non-ducted | 2.40 | 109% | 12.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 217596898 |
| 3796KEENUMHP09AAKEEN Home · KEEN Serieswith ductless indoor unit KEENOWAH09AA | KEEN Home | 1 ton9,000 Btu/h · Non-ducted | 1.83 | 97% | 12.1 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217596899 |
| 3797KEENUMHP12AAKEEN Home · KEEN Serieswith ductless indoor unit KEENOWAH12AA | KEEN Home | 1 ton12,000 Btu/h · Non-ducted | 1.99 | 92% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217596900 |
| 3798KEENUMHP18AAKEEN Home · KEEN Serieswith ductless indoor unit KEENOWAH18AA | KEEN Home | 1.5 tons16,700 Btu/h · Non-ducted | 1.89 | 88% | 12.2 | 20.6 | CEE 25CEE 26XcelES CC | 2 | 217596901 |
| 3799KEENUMHP24AAKEEN Home · KEEN Serieswith ductless indoor unit KEENFCAH24AA | KEEN Home | 2 tons22,000 Btu/h · Non-ducted | 2.16 | 93% | 12.1 | 20.4 | CEE 25CEE 26XcelES CC | 1 | 217596903 |
| 3800KEENUMHP36AAKEEN Home · KEEN Serieswith ductless indoor unit KEENFCAH36AA | KEEN Home | 3 tons36,400 Btu/h · Non-ducted | 2.02 | 104% | 10.8 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 217596904 |