Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.1%
Qualifying models
7,036
Qualifying certifications
221,680
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%92% of rated models reach 45% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF212,304 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0381
8.0 to under 8.3723
8.3 to under 8.5178
8.5 to under 8.81,451
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,371
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons62.1% · 2,928 of 4,715
2 tons67.6% · 1,181 of 1,748
2.5–3 tons57.3% · 1,560 of 2,724
3.5–4.5 tons45.5% · 1,222 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.5%2,089 / 6,056
Non-ducted69%2,820 / 4,087
Ducted and non-ducted97.2%2,127 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree580 of 71780.9%
Midea412 of 54675.5%
Carrier328 of 81640.2%
Daikin150 of 39438.1%
Lennox147 of 33743.6%
BlueRidge145 of 19275.5%
Trane140 of 36338.6%
TCL134 of 17775.7%
Hisense129 of 16180.1%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 242 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
6026H12SUH25XGCTCL · EXHEATwith ductless indoor unit H12SUH25XGETCL1 ton12,000 Btu/h · Non-ducted1.75100%10.525.0CEE 25CEE 26XcelES CC1216506201
6027H12SVH20BQCTCL · VoxIn 21Swith ductless indoor unit H12SVH20BQETCL1 ton12,000 Btu/h · Non-ducted1.8070%8.521.0CEE 25CEE 26Xcel1218330346
6028H12SVH20XQCTCL · VoxIn 21Swith ductless indoor unit H12SVH20XQETCL1 ton12,000 Btu/h · Non-ducted1.9062%8.521.0CEE 25CEE 261218330347
6029H18FMH22XPCTCL · MULIT ZONETCL1.5 tons17,000 Btu/h · Ducted and non-ducted1.9084%9.521.0CEE 25CEE 26XcelES CC2215387267
6030H18FMH24XQCTCL · free matcht 24S R32TCL1.5 tons18,000 Btu/h · Non-ducted2.0078%10.025.0CEE 25CEE 26XcelES CC1218451113
6031H18FMHD3XPCTCL · Apex Multi Match SeriesTCL1.5 tons20,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0099%10.027.0CEE 25CEE 26XcelES CC3218374501
6032H18SBH22XPCTCL · CELLING FLOOR-singlewith ductless indoor unit H18FCHU1XAETCL2 tons22,200 Btu/h · Non-ducted2.0079%9.520.0CEE 25CEE 26XcelES CC5216706236
6033H18SBH23XQCTCL · BreezeIN R32 23Swith ductless indoor unit H18SBH23XQETCL1.5 tons18,000 Btu/h · Non-ducted1.8083%10.024.0CEE 25CEE 26XcelES CC1218451105
6034H18SEH19XACTCLwith ductless indoor unit H18SEH19XAETCL1.5 tons18,000 Btu/h · Non-ducted1.8069%9.521.0CEE 25CEE 261215387254
6035H18SUH23XGCTCL · EXHEATwith ductless indoor unit H18SUH23XGETCL1.5 tons18,000 Btu/h · Non-ducted1.8099%10.023.5CEE 25CEE 26XcelES CC1216506202
6036H18SVH20XQCTCL · VoxIn 21Swith ductless indoor unit H18SVH20XQETCL1.5 tons17,500 Btu/h · Non-ducted1.9570%9.021.0CEE 25CEE 26Xcel1218330419
6037H18TDHXPCTCL · Front returnwith ducted air handler H18FAHUDETCL1.5 tons18,000 Btu/h · Ducted1.90100%9.517.0CEE 25CEE 26XcelES CC1218332482
6038H24SAH20XQCTCL · Savein 20Swith ductless indoor unit H24SAH20XQETCL2 tons24,000 Btu/h · Non-ducted1.8067%9.520.0CEE 25CEE 261218330417
6039H24SBH20XPCTCL · BREEZEINwith ductless indoor unit H24CSHU1XAETCL2 tons23,000 Btu/h · Non-ducted2.0077%10.022.0CEE 25CEE 26XcelES CC5215570376
6040H24SBH23XQCTCL · BreezeIN R32 23Swith ductless indoor unit H24SBH23XQETCL2 tons23,000 Btu/h · Non-ducted2.1073%10.023.0CEE 25CEE 26XcelES CC1218451106
6041H24SDH20XQCTCL · Apex XS Series Unitary HPwith ducted air handler H24APH20UDETCL2 tons24,000 Btu/h · Ducted1.85100%10.019.0CEE 25CEE 26XcelES CC1218453815
6042H24SEH19XACTCLwith ductless indoor unit H24SEH19XAETCL2 tons24,000 Btu/h · Non-ducted2.1068%9.521.0CEE 25CEE 261215387255
6043H24SUH23XGCTCL · EXHEATwith ductless indoor unit H24SUH23XGETCL2 tons24,000 Btu/h · Non-ducted1.8093%10.023.0CEE 25CEE 26XcelES CC2216506203
6044H24SVH20XQCTCL · VoxIn 21Swith ductless indoor unit H24SVH20XQETCL2 tons23,000 Btu/h · Non-ducted2.2555%9.021.0CEE 25CEE 261218330348
6045H24TDH17XACTCL · IVS 18with ducted air handler H24AHH17XAETCL2 tons24,000 Btu/h · Ducted1.8075%8.518.0CEE 25CEE 26XcelES CC2216706227
6046H24TDHXPCTCL · Front returnwith ducted air handler H24FAHUDETCL2 tons24,000 Btu/h · Ducted1.90125%9.517.0CEE 25CEE 26XcelES CC1218332483
6047H27FMH22XPCTCL · MULIT ZONETCL2.5 tons27,000 Btu/h · Ducted and non-ducted2.0071%10.524.0CEE 25CEE 26XcelES CC2215387264
6048H27FMH24XQCTCL · free matcht 24S R32TCL2.5 tons28,000 Btu/h · Non-ducted2.0075%10.022.0CEE 25CEE 26XcelES CC1218451114
6049H27FMHD4XPCTCL · Apex Multi Match SeriesTCL2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%10.526.5CEE 25CEE 26XcelES CC3218374502
6050H30TDHXPCTCL · Front returnwith ducted air handler H30FAHUDETCL2.5 tons30,000 Btu/h · Ducted1.90100%9.517.0CEE 25CEE 26XcelES CC1218332484

Explore qualifying models by COP at 5°F