Skip to content

CEE 2025 Tier 1 (Split ASHP): 7,036 qualifying heat pumps

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
57.1%
Qualifying models
7,036
Qualifying certifications
220,949
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2025 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%92% of rated models reach 45% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 45%45%
Baseline: Path A 60%60%

Source: AHRI Directory · as of

HSPF212,304 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0382
8.0 to under 8.3722
8.3 to under 8.5178
8.5 to under 8.81,451
8.8 to under 9.0196
9.0 to under 9.31,501
9.3 to under 9.5132
9.5 to under 9.81,370
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,102
15.5 to under 16.0283
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5918
20.5 to under 21.0161
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2025 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,870
12.5 to under 13.0950
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2025, by size
Show the data as a table
Share of models meeting CEE 2025, by size
GroupQualifying share
Up to 1.5 tons62.1% · 2,928 of 4,715
2 tons67.6% · 1,181 of 1,748
2.5–3 tons57.3% · 1,560 of 2,724
3.5–4.5 tons45.5% · 1,222 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted34.5%2,089 / 6,056
Non-ducted69%2,820 / 4,087
Ducted and non-ducted97.2%2,127 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree580 of 71780.9%
Midea412 of 54675.5%
Carrier328 of 81640.2%
Daikin150 of 39438.1%
Lennox147 of 33743.6%
BlueRidge145 of 19275.5%
Trane140 of 36338.6%
TCL134 of 17775.7%
Hisense129 of 16180.1%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2025 Tier 1 (Split ASHP), page 30 of 282
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
726BMS922XCBLUERIDGE · BMS Serieswith ductless indoor unit BMS922XWBlueRidge1 ton9,000 Btu/h · Non-ducted1.9570%9.021.5CEE 25CEE 26XcelES CC1215853887
727BMS922YCBLUERIDGE · BMS Serieswith ductless indoor unit BMS922YWBlueRidge1 ton9,000 Btu/h · Non-ducted1.9970%9.421.6CEE 25CEE 26XcelES CC1215853889
728BMS925XCBLUERIDGE · BMS Serieswith ductless indoor unit BMS925XWBlueRidge1 ton9,000 Btu/h · Non-ducted2.2272%10.025.4CEE 25CEE 26XcelES CC1215853895
729BMS926YCBLUERIDGE · BMS Serieswith ductless indoor unit BMC9HHYWBlueRidge1 ton9,000 Btu/h · Ducted and non-ducted2.3780%12.525.8CEE 25CEE 26XcelES CC6215853897
730BMS927HHYCBLUERIDGE · BMS Serieswith ducted air handler BMC9LCDBlueRidge1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.4CEE 25CEE 26XcelES CC6215853939
731BMS933SHYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS933SHYWBlueRidge1 ton9,000 Btu/h · Non-ducted2.00113%14.633.3CEE 25CEE 26XcelES CC1215853908
732BMSAH18HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH18IBlueRidge1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC2215853875
733BMSAH24HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH24IBlueRidge2 tons24,000 Btu/h · Ducted2.1486%10.018.6CEE 25CEE 26XcelES CC2215853876
734BMSAH30HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH30IBlueRidge2.5 tons30,000 Btu/h · Ducted1.97101%10.817.2CEE 25CEE 26XcelES CC2215853877
735BMSAH36HHCBLUERIDGE · BMS Serieswith ducted air handler BMS2AH36IBlueRidge3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC2215853872
736BMSAH48HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH48IBlueRidge4 tons48,000 Btu/h · Ducted2.00100%9.517.5CEE 25CEE 26XcelES CC2215853879
737BMSAH60HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH60IBlueRidge4.5 tons54,000 Btu/h · Ducted1.9098%9.517.5CEE 25CEE 26XcelES CC2215853880
738BMSAHS1819CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH18IBlueRidge1.5 tons18,000 Btu/h · Ducted2.0062%9.118.8CEE 25CEE 261215853863
739BMSAHS2418CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH24IBlueRidge2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC1215853864
740BMSAHS3017CBLUERIDGEwith ducted air handler BMS2AH30IBlueRidge2.5 tons30,000 Btu/h · Ducted2.0062%8.517.0CEE 251215853865
741BMSAHS3616CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH36IBlueRidge3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC1215853866
742BMSAHS4816CBLUERIDGE · BMS Serieswith ducted air handler BMS2AH48IBlueRidge4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC1215853867
743BNG2A18SCNBLUERIDGE · BNG Serieswith ducted air handler BNGFA18DH2BlueRidge1.5 tons18,000 Btu/h · Ducted2.0062%9.118.8CEE 25CEE 263216997498
744BNG2A24SCNBLUERIDGE · BNG Serieswith ducted air handler BNGFA24DH2BlueRidge2 tons24,000 Btu/h · Ducted1.8783%9.718.1CEE 25CEE 26XcelES CC3216997499
745BNG2A30SCNBLUERIDGEwith ducted air handler BNGFA30DH2BlueRidge2.5 tons30,000 Btu/h · Ducted2.0062%8.517.0CEE 254216997500
746BNG2A36SCNBLUERIDGE · BNG Serieswith ducted air handler BNGFA36DH2BlueRidge3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC4216997501
747BNG2A48SCNBLUERIDGE · BNG Serieswith ducted air handler BNGFA48DH2BlueRidge4 tons48,000 Btu/h · Ducted1.8579%8.516.0CEE 25CEE 26XcelES CC3216997502
748BNG2Z30SCNBLUERIDGE · NG2with ducted air handler BNG2Z30DH0BlueRidge2.5 tons27,000 Btu/h · Ducted2.1470%8.318.0CEE 25CEE 26Xcel2217992599
749BNG2Z36SCMBLUERIDGE · NG2with ducted air handler BNGFZ36DH0BlueRidge3 tons34,000 Btu/h · Ducted2.0064%8.319.0CEE 25CEE 261217992601
750BNG2Z36SCNBLUERIDGE · NG2with ducted air handler BNGFZ36DH0BlueRidge3 tons34,000 Btu/h · Ducted2.0064%8.319.0CEE 25CEE 261218043771

Explore qualifying models by COP at 5°F