Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2025 Tier 1 (Split ASHP): 7,039 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
New to heat pump ratings? The Simple view explains them in plain words →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.1%
- Qualifying models
- 7,039
- Qualifying certifications
- 221,695
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,238 |
| 1.90 to under 2.00 | 1,351 |
| 2.00 to under 2.10 | 2,428 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 777 |
| 2.30 to under 2.40 | 512 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 519 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,400 |
| 75 to under 80% | 1,156 |
| 80 to under 85% | 799 |
| 85 to under 90% | 375 |
| 90 to under 95% | 720 |
| 95 to under 100% | 582 |
| 100 to under 105% | 758 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,112 |
| 7.8 to under 8.0 | 381 |
| 8.0 to under 8.3 | 724 |
| 8.3 to under 8.5 | 177 |
| 8.5 to under 8.8 | 1,450 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,500 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,372 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,627 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 603 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 14 |
| 13.0 to under 13.5 | 900 |
| 13.5 to under 14.0 | 338 |
| 14.0 to under 14.5 | 1,004 |
| 14.5 to under 15.0 | 192 |
| 15.0 to under 15.5 | 1,100 |
| 15.5 to under 16.0 | 284 |
| 16.0 to under 16.5 | 624 |
| 16.5 to under 17.0 | 188 |
| 17.0 to under 17.5 | 848 |
| 17.5 to under 18.0 | 214 |
| 18.0 to under 18.5 | 681 |
| 18.5 to under 19.0 | 393 |
| 19.0 to under 19.5 | 745 |
| 19.5 to under 20.0 | 182 |
| 20.0 to under 20.5 | 917 |
| 20.5 to under 21.0 | 162 |
| 21.0 to under 21.5 | 783 |
| 21.5 to under 22.0 | 162 |
| 22.0 to under 22.5 | 508 |
| 22.5 to under 23.0 | 197 |
| 23.0 to under 23.5 | 661 |
| 23.5 to under 24.0 | 111 |
| 24.0 to under 24.5 | 294 |
| 24.5 to under 25.0 | 151 |
| 25.0 to under 25.5 | 286 |
| 25.5 to under 26.0 | 75 |
| 26.0 to under 26.5 | 39 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 61 |
| 27.5 to under 28.0 | 22 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 22 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.0 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 2 |
| 8.0 to under 8.5 | 94 |
| 8.5 to under 9.0 | 214 |
| 9.0 to under 9.5 | 703 |
| 9.5 to under 10.0 | 831 |
| 10.0 to under 10.5 | 881 |
| 10.5 to under 11.0 | 1,359 |
| 11.0 to under 11.5 | 1,679 |
| 11.5 to under 12.0 | 1,904 |
| 12.0 to under 12.5 | 1,869 |
| 12.5 to under 13.0 | 951 |
| 13.0 to under 13.5 | 914 |
| 13.5 to under 14.0 | 232 |
| 14.0 to under 14.5 | 275 |
| 14.5 to under 15.0 | 114 |
| 15.0 to under 15.5 | 180 |
| 15.5 to under 16.0 | 5 |
| 16.0 to under 16.5 | 31 |
| 16.5 to under 17.0 | 23 |
| 17.0 to under 17.5 | 35 |
| 17.5 and above | 31 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons62.1% · 2,929 of 4,716
- 2 tons67.6% · 1,181 of 1,748
- 2.5–3 tons57.3% · 1,562 of 2,726
- 3.5–4.5 tons45.5% · 1,222 of 2,687
- 5 tons and up31.7% · 145 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 62.1% · 2,929 of 4,716 |
| 2 tons | 67.6% · 1,181 of 1,748 |
| 2.5–3 tons | 57.3% · 1,562 of 2,726 |
| 3.5–4.5 tons | 45.5% · 1,222 of 2,687 |
| 5 tons and up | 31.7% · 145 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.5% | 2,090 / 6,057 |
| Non-ducted | 69% | 2,822 / 4,089 |
| Ducted and non-ducted | 97.2% | 2,127 / 2,189 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 580 of 717 | 80.9% |
| Midea | 412 of 546 | 75.5% |
| Carrier | 328 of 816 | 40.2% |
| Daikin | 150 of 394 | 38.1% |
| Lennox | 147 of 337 | 43.6% |
| BlueRidge | 145 of 192 | 75.5% |
| Trane | 140 of 363 | 38.6% |
| TCL | 134 of 177 | 75.7% |
| Hisense | 129 of 161 | 80.1% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 2401FPHMR36A3DFriedrich · Floating Air Pro X Multi-Zone | Friedrich | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 100% | 10.0 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 215792846 |
| 2402FPHMR42A3DFriedrich · Floating Air Pro X Multi-Zone | Friedrich | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 75% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 215792843 |
| 2403FPHSR09A1BFRIEDRICHwith ductless indoor unit FAHSW09A1A | Friedrich | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 97% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 2 | 214826547 |
| 2404FPHSR09A1CFriedrich · Floating Air Prowith ductless indoor unit FAHSW09A1C | Friedrich | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 97% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 2 | 215792219 |
| 2405FPHSR09A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW09A3A | Friedrich | 1 ton9,000 Btu/h · Non-ducted | 2.09 | 100% | 11.0 | 25.0 | CEE 25CEE 26XcelES CC | 2 | 214232408 |
| 2406FPHSR09A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW09A3D | Friedrich | 1 ton9,000 Btu/h · Non-ducted | 2.09 | 100% | 11.0 | 25.0 | CEE 25CEE 26XcelES CC | 2 | 215792221 |
| 2407FPHSR12A1BFRIEDRICHwith ductless indoor unit FAHSW12A1A | Friedrich | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 2 | 214826548 |
| 2408FPHSR12A1CFriedrich · Floating Air Prowith ductless indoor unit FAHSW12A1C | Friedrich | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 2 | 215792220 |
| 2409FPHSR12A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW12A3A | Friedrich | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 92% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 2 | 214237688 |
| 2410FPHSR12A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW12A3D | Friedrich | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 92% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 2 | 215792222 |
| 2411FPHSR18A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW18A3A | Friedrich | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 2 | 214142519 |
| 2412FPHSR18A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW18A3D | Friedrich | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 2 | 215792223 |
| 2413FPHSR24A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW24A3A | Friedrich | 2 tons24,000 Btu/h · Non-ducted | 2.00 | 83% | 9.5 | 22.5 | CEE 25CEE 26XcelES CC | 2 | 214091820 |
| 2414FPHSR24A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW24A3D | Friedrich | 2 tons24,000 Btu/h · Non-ducted | 2.00 | 83% | 9.5 | 22.5 | CEE 25CEE 26XcelES CC | 2 | 215792224 |
| 2415FRP15AY42AJ2NFRIEDRICHwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | Friedrich | 3.5 tons39,000 Btu/h · Ducted | 2.20 | 51% | 7.8 | 15.2 | CEE 25ES CC | 148 | 216721555 |
| 2416FRP15AY48AJ2NFRIEDRICHwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | Friedrich | 4 tons45,000 Btu/h · Ducted | 2.30 | 54% | 7.8 | 15.2 | CEE 25CEE 26ES CC | 155 | 216721554 |
| 2417FRP17AY24AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY2417STANM and furnace FR972V0403A14UDS | Friedrich | 2 tons22,400 Btu/h · Ducted | 2.20 | 72% | 8.1 | 16.0 | CEE 25CEE 26XcelES CC | 92 | 218719256 |
| 2418FRP17AY36AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY3617STANM and furnace FR801V0503A14DZN | Friedrich | 3 tons34,200 Btu/h · Ducted | 2.00 | 91% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 247 | 218327885 |
| 2419FRP17AY48AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY4821STANM and furnace FR972V0705A21UPS | Friedrich | 3.5 tons44,500 Btu/h · Ducted | 2.10 | 75% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 192 | 218719321 |
| 2420FRP17AY60AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY6024STANM and furnace FR802V1005A21UHS | Friedrich | 4.5 tons56,500 Btu/h · Ducted | 2.00 | 80% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 79 | 218328121 |
| 2421FRP19AY24AJVCFRIEDRICH · K SERIESwith indoor coil TCFY2421HEAAM and furnace FR972V0603A17UPS | Friedrich | 2 tons22,800 Btu/h · Ducted | 2.10 | 77% | 8.5 | 21.0 | CEE 25CEE 26XcelES CC | 60 | 218728652 |
| 2422FRP19AY36AJVCFRIEDRICH · K SERIESwith indoor coil RCFY3621MEAAM and furnace FR972V0603A17UPS | Friedrich | 3 tons34,200 Btu/h · Ducted | 2.20 | 77% | 8.5 | 20.0 | CEE 25CEE 26XcelES CC | 37 | 218728667 |
| 2423FRP19AY48AJVCFRIEDRICH · K SERIESwith indoor coil RCFY4821SEAAM and furnace FR972V0705A21UPS | Friedrich | 4 tons45,500 Btu/h · Ducted | 2.20 | 76% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 28 | 218728685 |
| 2424FRP19AY60AJVCFRIEDRICH · K SERIESwith indoor coil RCFY6021SEAAM and furnace FR972V0855A21UPS | Friedrich | 4.5 tons53,500 Btu/h · Ducted | 2.10 | 84% | 8.1 | 17.0 | CEE 25CEE 26Xcel | 27 | 218728700 |
| 2425FSHSR09B1BFRIEDRICHwith ductless indoor unit FAHSW09A1A | Friedrich | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 63% | 9.0 | 20.0 | CEE 25CEE 26 | 2 | 214731356 |