Skip to content

CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
7,576
Qualifying certifications
217,907
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%88% of rated models reach 50% (the lowest path) on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.076% of rated models reach 8 (the lowest path) on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.170% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.5At least 84% of rated models reach 9.8 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.3% · 3,270 of 5,427
2 tons65.9% · 1,279 of 1,941
2.5 to 3 tons54.8% · 1,612 of 2,942
3.5 to 4.5 tons44.6% · 1,264 of 2,834
5 tons and up31.8% · 151 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.8%2,113 / 6,438
Non-ducted66.3%3,223 / 4,861
Ducted and non-ducted96.6%2,240 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea412 of 55574.2%
Carrier313 of 84637%
Daikin145 of 41035.4%
TCL144 of 19275%
BlueRidge142 of 19473.2%
Lennox139 of 34140.8%
Trane134 of 37036.2%
York130 of 23954.4%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 12 of 304
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
276AASDCI7H4R30AIR-CON · G Serieswith ducted air handler AASDEM7H4R30-SAIR-CON2.5 tons27,000 Btu/h · Ducted2.1472%8.317.5CEE 25CEE 26Xcel2217655824
277AASDCI7H4R36AIR-CON · G Serieswith ducted air handler AASDEM7H4R36-SAIR-CON3 tons34,000 Btu/h · Ducted2.0064%8.318.5CEE 25CEE 261217655823
278AASDCI7H4R60AIR-CON · G Serieswith ducted air handler AASDEM7H4R60-SAIR-CON4.5 tons53,500 Btu/h · Ducted2.2474%9.518.8CEE 25CEE 26Xcel2217655822
279ASGCI8H4M18AIR-CONwith ducted air handler ASGEK8H4M18AIR-CON1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.320.0CEE 25CEE 26Xcel3217291581
280ASGCI8H4M24AIR-CONwith ductless indoor unit ASGEC8H4M24AIR-CON2 tons24,000 Btu/h · Non-ducted2.3074%10.522.0CEE 25CEE 26Xcel2217291583
281ASGCI8H4M48AIR-CONwith ductless indoor unit ASGEC8H4M48AIR-CON4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.0CEE 25CEE 26Xcel3217291589
282ASGCI8H4M60AIR-CONwith ducted air handler ASGEK8H4M60AIR-CON5 tons58,000 Btu/h · Ducted and non-ducted2.2067%9.717.0CEE 25CEE 262217291590
283AVDCI7H4T24AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T24AIR-CON2 tons24,000 Btu/h · Ducted2.1579%9.519.0CEE 25CEE 26Xcel1217548263
284AVDCI7H4T36AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T36AIR-CON3 tons33,000 Btu/h · Ducted2.0073%8.818.0CEE 25CEE 26Xcel1217548264
285AVDCI7H4T48AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T48AIR-CON4 tons47,000 Btu/h · Ducted2.3072%9.218.5CEE 25CEE 26Xcel1217548265
286AVDCI7H4T60AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T60AIR-CON4.5 tons55,000 Btu/h · Ducted2.3073%8.818.0CEE 25CEE 26Xcel1217548266
287AVPI7H4T24AIR-CONAIR-CON2 tons24,000 Btu/h · Ducted2.00103%9.019.0CEE 25CEE 26Xcel1218644490
288AVPI7H4T36AIR-CONAIR-CON3 tons33,000 Btu/h · Ducted2.0085%9.018.5CEE 25CEE 26Xcel1218644491
289AVPI7H4T48AIR-CONAIR-CON4 tons48,000 Btu/h · Ducted2.1073%8.818.0CEE 25CEE 26Xcel1218644492
290AVPI7H4T60AIR-CONAIR-CON4.5 tons56,000 Btu/h · Ducted2.0071%8.817.0CEE 25CEE 26Xcel1218644493
291HHHT-M-1-OUTAircoldwith ductless indoor unit HHHT-M-1-INAircold1 ton12,000 Btu/h · Non-ducted2.1075%9.522.0CEE 25CEE 26Xcel1218078178
292HHHT-M-2-OUTAircoldwith ductless indoor unit HHHT-M-2-INAircold1 ton12,000 Btu/h · Non-ducted2.0074%9.522.0CEE 25CEE 26Xcel1218078179
293A3TH36180OV1DGAirdachwith ducted air handler A3DH36000OE1DTAirdach3 tons33,000 Btu/h · Ducted2.0073%8.818.0CEE 25CEE 26Xcel1218797045
294A3TH60180OV1DGAirdachwith ducted air handler A3DH60000OE1DTAirdach4.5 tons55,000 Btu/h · Ducted2.3073%8.818.0CEE 25CEE 26Xcel1218797046
295A4TH36200MV1DGAIRDACHwith ducted air handler A4DH2400ME1DTAirdach2 tons24,000 Btu/h · Ducted2.0073%9.520.0CEE 25CEE 26Xcel2218045422
296A4TH60200MV1DGAIRDACHwith ducted air handler A4DH4800ME1DTAirdach4 tons47,000 Btu/h · Ducted2.0070%9.518.5CEE 25CEE 26Xcel2218045424
297ACSH0919VA1A3Airdachwith ductless indoor unit AIWH0900VA1A3Airdach1 ton9,100 Btu/h · Non-ducted1.8088%8.520.5CEE 25CEE 26Xcel1218071698
298ACSH0920VR1-A3Airdachwith ductless indoor unit AIWH0900VR1-A3Airdach1 ton9,100 Btu/h · Non-ducted1.8676%8.820.5CEE 25CEE 26Xcel1217101995
299ACSH0920VR1-D3Airdachwith ductless indoor unit AIWH0900VR1-D3Airdach1 ton9,100 Btu/h · Non-ducted1.9476%8.820.5CEE 25CEE 26Xcel1217101992
300ACSH1820VR1-D3Airdachwith ductless indoor unit AIWH1800VR1-D3Airdach1.5 tons18,000 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26Xcel1217101993

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report