Both views use the same certified data. This device remembers your choice.
DOE Cold Climate Heat Pump Challenge: 338 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
Simple view, for homeowners: top picks by size and what each rating measures →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 2.5%
- Qualifying models
- 338
- Qualifying certifications
- 1,206
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons3.3% · 180 of 5,427
- 2 tons1.9% · 37 of 1,941
- 2.5 to 3 tons2.1% · 63 of 2,942
- 3.5 to 4.5 tons2% · 56 of 2,834
- 5 tons and up0.4% · 2 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 3.3% · 180 of 5,427 |
| 2 tons | 1.9% · 37 of 1,941 |
| 2.5 to 3 tons | 2.1% · 63 of 2,942 |
| 3.5 to 4.5 tons | 2% · 56 of 2,834 |
| 5 tons and up | 0.4% · 2 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 1.8% | 117 / 6,438 |
| Non-ducted | 2% | 98 / 4,861 |
| Ducted and non-ducted | 5.3% | 123 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 176KOB-HH-PSX06HP-2AAMAKADEN · KO Serieswith ductless indoor unit KIB-PSX06WM-2AAMA | Kaden | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 215866628 |
| 177KOB-HH-UUX18HP-2AAMAKADEN · KO Serieswith ducted air handler KIB-HH-UUX18AH3-2AAMA | Kaden | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217970408 |
| 178KEENHYDHP18AAKEEN Home · KEEN Serieswith ducted air handler KEENULDAH18AA | KEEN Home | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 217596881 |
| 179KEENUMHP06AAKEEN Home · KEEN Serieswith ductless indoor unit KEENOWAH06AA | KEEN Home | 0.5 tons6,500 Btu/h · Non-ducted | 2.40 | 109% | 12.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 217596898 |
| 180ODUMOX230-06HFN10-M1XKepler · ODU Serieswith ducted air handler IDUMTI-06HWFN10-M1-D | Kepler | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218857674 |
| 181A-KHP06SA-1Kerr · A-KHP Serieswith ductless indoor unit B-KHP06SA-1 | Kerr | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 216097110 |
| 182A-VHP06SA-1COMFORT-AIRE · A-VHP Serieswith ductless indoor unit B-VHP06SA-1 | Lennox | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 216097104 |
| 183A-VXP18SA-1Comfort Aire · A Serieswith ducted air handler WXP18SA | Lennox | 1.5 tons18,000 Btu/h · Ducted | 2.10 | 103% | 10.8 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 217482406 |
| 184MWLD009S6S-1PLENNOX · MWLD Mini-Splitwith ductless indoor unit MWMD009S6-1P | Lennox | 1 ton9,000 Btu/h · Non-ducted | 2.15 | 114% | 10.5 | 25.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216411305 |
| 185MWLD015S6S-1PLENNOX · MWLD Mini-Splitwith ductless indoor unit MWMD015S6-1P | Lennox | 1.5 tons15,000 Btu/h · Non-ducted | 2.50 | 104% | 11.0 | 23.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216411307 |
| 186MWPD009S6S-1PLENNOX · MWPD Mini-Splitwith ductless indoor unit MWMD009S6-1P | Lennox | 1 ton9,000 Btu/h · Non-ducted | 2.15 | 114% | 10.5 | 25.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216411310 |
| 187MWPD015S6S-1PLENNOX · MWPD Mini-Splitwith ductless indoor unit MWMD015S6-1P | Lennox | 1.5 tons15,000 Btu/h · Non-ducted | 2.50 | 104% | 11.0 | 23.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216411312 |
| 188SL22KLV-024-230A**LENNOXwith indoor coil D(A,C,E)25D4J+TDR and furnace SLP99UH090XV36C | Lennox | 2 tons21,000 Btu/h · Ducted | 2.60 | 98% | 9.5 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 444 | 217443773 |
| 189SL22KLV-036-230A**LENNOXwith indoor coil D(A,C,E)37D4J+TDR and furnace SLP99UH090XV48C | Lennox | 2.5 tons32,600 Btu/h · Ducted | 2.76 | 105% | 9.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 182 | 217443793 |
| 190SL22KLV-060-230A**LENNOXwith indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60C | Lennox | 4.5 tons52,500 Btu/h · Ducted | 3.09 | 115% | 9.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 199 | 217443918 |
| 191KUMXA181ALG · KUMXA181A | LG | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.25 | 100% | 9.8 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214848473 |
| 192KUMXA241ALG · KUMXA241A | LG | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.13 | 100% | 9.8 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214848475 |
| 193KUMXA301ALG · KUMXA301A | LG | 2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.24 | 100% | 9.8 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214848477 |
| 194KUMXA361ALG · KUMXA361A | LG | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.27 | 100% | 11.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402345 |
| 195KUMXA421ALG · KUMXA421A | LG | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.29 | 100% | 11.0 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215402347 |
| 196KUMXA481ALG · KUMXA481A | LG | 4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.34 | 100% | 10.5 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215408636 |
| 197KUSXA241ALGwith ducted air handler D(A,C,E)25C3D+TDR | LG | 1.5 tons20,200 Btu/h · Ducted and non-ducted | 2.88 | 67% | 8.5 | 14.8 | CEE 25CEE 26CEE AdvXcelDOEES CC | 73 | 217198614 |
| 198KUSXA301ALGwith ducted air handler C(A,C,D,E)30C3D+TDR | LG | 2 tons21,400 Btu/h · Ducted and non-ducted | 3.43 | 61% | 8.5 | 15.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 96 | 217198620 |
| 199KUSXB091ALG · KUSXB091Awith ducted air handler KNUJB091A | LG | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.30 | 78% | 10.4 | 16.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 214826531 |
| 200KUSXB241ALGwith ducted air handler D(A,C,E)30C3D+TDR | LG | 1.5 tons20,400 Btu/h · Ducted and non-ducted | 2.95 | 67% | 8.5 | 15.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 112 | 217198651 |