Both views use the same certified data. This device remembers your choice.
ENERGY STAR Cold Climate: 5,489 qualifying heat pumps
Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).
Simple view, for homeowners: top picks by size and what each rating measures →
U.S. EPAData as of updated · sources
- Share of models
- 40.3%
- Qualifying models
- 5,489
- Qualifying certifications
- 134,768
- Paths
- Listing
Criteria
No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.
Source: U.S. EPA
Qualification by size
- Up to 1.5 tons45% · 2,441 of 5,427
- 2 tons44.4% · 861 of 1,941
- 2.5 to 3 tons37.9% · 1,114 of 2,942
- 3.5 to 4.5 tons36.1% · 1,022 of 2,834
- 5 tons and up10.7% · 51 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 45% · 2,441 of 5,427 |
| 2 tons | 44.4% · 861 of 1,941 |
| 2.5 to 3 tons | 37.9% · 1,114 of 2,942 |
| 3.5 to 4.5 tons | 36.1% · 1,022 of 2,834 |
| 5 tons and up | 10.7% · 51 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 26.1% | 1,679 / 6,438 |
| Non-ducted | 39.1% | 1,903 / 4,861 |
| Ducted and non-ducted | 82.2% | 1,907 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 477 of 729 | 65.4% |
| Midea | 355 of 555 | 64% |
| Carrier | 232 of 846 | 27.4% |
| Ephoca | 186 of 382 | 48.7% |
| Innova | 186 of 382 | 48.7% |
| BlueRidge | 125 of 194 | 64.4% |
| TCL | 124 of 192 | 64.6% |
| Rheem | 115 of 346 | 33.2% |
| Mitsubishi Electric | 103 of 156 | 66% |
| Lennox | 100 of 341 | 29.3% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 276ALC24-36H1BAprodr · ALC Serieswith ductless indoor unit CCA22-36HRFN1 | Aprodr | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.3 | 20.0 | CEE 25XcelES CC | 2 | 218035859 |
| 277ALC24-48H1BAprodr · ALC Serieswith ductless indoor unit CCA22-48HRFN1 | Aprodr | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.0 | CEE 25CEE 26XcelES CC | 2 | 218035860 |
| 278AM3OA-18HFN1Aprodr · AM Series | Aprodr | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.30 | 77% | 10.0 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217334316 |
| 279AM4OJ-27HFN1Aprodr · AM Series | Aprodr | 2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 217334318 |
| 280AM5OG-36HFN1Aprodr · AM Series | Aprodr | 3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 10.0 | 23.1 | CEE 25CEE 26XcelES CC | 3 | 217334321 |
| 281AM6OG-48HFN1Aprodr · AM Series | Aprodr | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 75% | 10.0 | 21.3 | CEE 25CEE 26XcelES CC | 3 | 217334324 |
| 282ASG24-09H1BAprodr · ASG Serieswith ductless indoor unit ASG24-09H1A | Aprodr | 1 ton9,000 Btu/h · Non-ducted | 2.21 | 73% | 10.7 | 24.5 | CEE 25CEE 26XcelES CC | 1 | 218035844 |
| 283ASG24-09H220V1BAprodr · ASG Serieswith ductless indoor unit ASG24-09H220V1A | Aprodr | 1 ton9,000 Btu/h · Non-ducted | 2.33 | 82% | 13.0 | 24.6 | CEE 25CEE 26XcelES CC | 1 | 218035846 |
| 284ASG24-12H220V1BAprodr · ASG Serieswith ductless indoor unit ASG24-12H220V1A | Aprodr | 1 ton12,000 Btu/h · Non-ducted | 2.36 | 72% | 11.5 | 23.1 | CEE 25CEE 26XcelES CC | 1 | 218035847 |
| 285ASG24-18H1BAprodr · ASG Serieswith ductless indoor unit ASG24-18H1A | Aprodr | 1.5 tons18,000 Btu/h · Non-ducted | 2.35 | 72% | 11.1 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 218035848 |
| 286ASG24-24H1BAprodr · ASG Serieswith ductless indoor unit ASG24-24H1A | Aprodr | 2 tons24,000 Btu/h · Non-ducted | 2.15 | 71% | 10.0 | 23.5 | CEE 25CEE 26XcelES CC | 1 | 218035849 |
| 287ATPRO24-09H1BAproDr · 24 SEER2with ductless indoor unit ATPRO24-09H1A | Aprodr | 1 ton9,000 Btu/h · Non-ducted | 1.89 | 75% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217221830 |
| 288ATPRO24-09H220V1BAproDr · 24 SEER2with ductless indoor unit ATPRO24-09H220V1A | Aprodr | 1 ton9,000 Btu/h · Non-ducted | 1.84 | 71% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217221832 |
| 289ATPRO24-12H1BAproDr · 24 SEER2with ductless indoor unit ATPRO24-12H1A | Aprodr | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217221831 |
| 290ATPRO24-12H220V1BAproDr · 24 SEER2with ductless indoor unit ATPRO24-12H220V1A | Aprodr | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217221833 |
| 291ATPRO24-18H1BAproDr · 24 SEER2with ductless indoor unit ATPRO24-18H1A | Aprodr | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217221834 |
| 292ATPRO24-24H1BAproDr · 24 SEER2with ductless indoor unit ATPRO24-24H1A | Aprodr | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 76% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217221835 |
| 293AB-GTMH18-230VOArmbridge · Multi-spilt series | Armbridge | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 104% | 11.0 | 23.3 | CEE 25CEE 26XcelES CC | 3 | 218059652 |
| 294AB-GTMH24-230VOArmbridge · Multi-spilt series | Armbridge | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.5 | 24.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218059653 |
| 295AB-GTMH36-230VOArmbridge · Multi-spilt series | Armbridge | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 92% | 11.0 | 24.0 | CEE 25CEE 26XcelES CC | 3 | 218059654 |
| 296AB-GTMH42-230VOArmbridge · Multi-spilt series | Armbridge | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 83% | 10.0 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218059664 |
| 297AB-GTMR18-230VOArmbridge · Multi-spilt series | Armbridge | 1.5 tons17,700 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 81% | 10.0 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218059647 |
| 298AB-GTMR24-230VOArmbridge · Multi-spilt series | Armbridge | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 218059648 |
| 299AB-GTMR30-230VOArmbridge · Multi-spilt series | Armbridge | 2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 77% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218059658 |
| 300AB-GTMR36-230VOArmbridge · Multi-spilt series | Armbridge | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 70% | 10.0 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218059659 |