Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
52.7%
Qualifying models
7,174
Qualifying certifications
197,833
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%64% of rated models reach 70% on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.1At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons60.7% · 3,292 of 5,427
2 tons59.4% · 1,152 of 1,941
2.5 to 3 tons50.4% · 1,483 of 2,942
3.5 to 4.5 tons42.2% · 1,195 of 2,834
5 tons and up10.9% · 52 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.2%2,070 / 6,438
Non-ducted61.3%2,978 / 4,861
Ducted and non-ducted91.6%2,126 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea387 of 55569.7%
Carrier246 of 84629.1%
TCL138 of 19271.9%
BlueRidge132 of 19468%
Daikin125 of 41030.5%
AUX124 of 18965.6%
Lennox121 of 34135.5%
Ephoca120 of 38231.4%
Innova120 of 38231.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 108 of 287
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2676GNS12HCH23R454OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS12HCH23R454IGENERALLUX STAR1 ton12,000 Btu/h · Non-ducted2.0092%10.023.0CEE 25CEE 26Xcel1215887346
2677GNS18HCH21R32OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS18HCH21R32IGENERALLUX STAR1.5 tons18,000 Btu/h · Non-ducted2.4976%9.821.0CEE 25CEE 26Xcel1215887344
2678GNS18HCH21R454OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS18HCH21R454IGENERALLUX STAR1.5 tons18,000 Btu/h · Non-ducted1.90100%10.021.0CEE 25CEE 26Xcel1215887347
2679GNS24HCH20R32OGENERALLUX STARwith ductless indoor unit GNS24HCH20R32IGENERALLUX STAR2 tons24,000 Btu/h · Non-ducted1.9077%8.519.5CEE 25CEE 26Xcel1215887345
2680GNS24HCH23R454OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS24HCH23R454IGENERALLUX STAR2 tons24,000 Btu/h · Non-ducted1.8483%9.522.5CEE 25CEE 26Xcel1215887348
2681A7CP21V24P-**AAC PRO · A7CP21V Serieswith ducted air handler 7AH2AV24PXCGree2 tons23,600 Btu/h · Ducted2.3075%10.020.5CEE 25CEE 26XcelES CC121217465740
2682A7CP21V36P-**AAC PRO · A7CP21V Serieswith indoor coil 7EH30BX-**+TDR and furnace A80UH2E090B12Gree3 tons33,200 Btu/h · Ducted2.4673%9.019.0CEE 25CEE 26XcelES CC161217466086
2683A7CP21V48P-**AAC PRO · A7CP21V Serieswith ducted air handler 7AH1AE60PX-Gree4 tons47,000 Btu/h · Ducted2.2079%9.019.5CEE 25CEE 26XcelES CC126217465940
2684A7CP21V60P-**AAC PRO · A7CP21V Serieswith indoor coil 7E[C,U]60CX-**+TDR and furnace A80US2V090C20Gree4.5 tons55,000 Btu/h · Ducted2.1865%8.520.5CEE 25CEE 26XcelES CC84217465776
2685AIRY09HP230V1AOGREE · Airywith ductless indoor unit AIRY09HP230V1AHGree1 ton9,100 Btu/h · Non-ducted2.11108%11.230.0CEE 25CEE 26CEE AdvXcelDOEES CC1217175296
2686AIRY12HP230V1AOGREE · Airywith ductless indoor unit AIRY12HP230V1AHGree1 ton12,000 Btu/h · Non-ducted2.00100%10.029.5CEE 25CEE 26XcelES CC1217175297
2687AIRY18HP230V1AOGREE · Airywith ductless indoor unit AIRY18HP230V1AHGree1.5 tons18,000 Btu/h · Non-ducted1.8097%10.027.5CEE 25CEE 26XcelES CC1217175298
2688AIRY24HP230V1AOGREE · Airywith ductless indoor unit AIRY24HP230V1AHGree2 tons22,000 Btu/h · Non-ducted1.80100%10.027.0CEE 25CEE 26XcelES CC1217175299
2689BH719M36P-**AAC PRO · BH719M Serieswith indoor coil BC748DCT-**+TDR and furnace B97DR902E4CGree3 tons34,800 Btu/h · Ducted2.2047%8.516.5CEE 25CEE 26Xcel317217504768
2690CHM09HP230V1R32AOGREE · Charmowith ductless indoor unit CHM09HP230V1R32AHGree1 ton9,100 Btu/h · Non-ducted1.9476%8.820.5CEE 25CEE 26XcelES CC1217607995
2691CHM12HP230V1R32AOGREE · Charmowith ductless indoor unit CHM12HP230V1R32AHGree1 ton12,000 Btu/h · Non-ducted1.7576%8.519.0XcelES CC1217607996
2692CHM18HP230V1R32AOGREE · Charmowith ductless indoor unit CHM18HP230V1R32AHGree1.5 tons18,000 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26XcelES CC1217607997
2693CHM30HP230V1R32AOGREEwith ductless indoor unit CHM30HP230V1R32AHGree2.5 tons30,000 Btu/h · Non-ducted1.8077%9.022.0CEE 25CEE 26Xcel1217607999
2694CHM36HP230V1R32AOGREE · Charmowith ductless indoor unit CHM36HP230V1R32AHGree3 tons33,600 Btu/h · Non-ducted1.8072%8.521.0CEE 25CEE 26XcelES CC1217608000
2695ENV09HP115V1R32AOGREE · Cliviawith ductless indoor unit ENV09HP115V1R32AHGree1 ton9,100 Btu/h · Non-ducted1.8392%10.527.0CEE 25CEE 26XcelES CC1214779341
2696ENV09HP230V1R32AOGREE · Ductedwith ducted air handler DUC09HP230V1R32AHGree1 ton9,100 Btu/h · Ducted and non-ducted2.1490%9.222.0CEE 25CEE 26XcelES CC6215413812
2697ENV12HP115V1R32AOGREE · Cliviawith ductless indoor unit ENV12HP115V1R32AHGree1 ton12,000 Btu/h · Non-ducted1.9579%9.524.5CEE 25CEE 26XcelES CC1214779343
2698ENV12HP230V1R32AOGREE · Cliviawith ductless indoor unit ENV12HP230V1R32AHGree1 ton12,000 Btu/h · Ducted and non-ducted1.9592%9.524.5CEE 25CEE 26XcelES CC6214779344
2699ENV18HP230V1R32AOGREE · Cliviawith ductless indoor unit ENV18HP230V1R32AHGree1.5 tons18,000 Btu/h · Ducted and non-ducted1.9081%9.024.5CEE 25CEE 26XcelES CC8214777850
2700ENV24HP230V1R32AOGREEwith ducted air handler DUC24HP230V1R32AHGree2 tons22,000 Btu/h · Ducted and non-ducted1.8082%9.019.5CEE 25CEE 26XcelES CC4215415518

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter