Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,515 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,515
Qualifying certifications
189,411
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.6% · 2,905 of 4,715
2 tons60.8% · 1,062 of 1,748
2.5–3 tons50.3% · 1,369 of 2,724
3.5–4.5 tons42.1% · 1,130 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,933 / 6,056
Non-ducted63%2,573 / 4,087
Ducted and non-ducted91.8%2,009 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Lennox121 of 33735.9%
Ephoca120 of 38231.4%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 208 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
5176ML06HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML06HP230CALH-IRheem0.5 tons6,000 Btu/h · Non-ducted2.00150%15.635.0CEE 25CEE 26XcelES CC2215864344
5177ML06HP230NEXH-OMAINLINE · ML Serieswith ducted air handler ML06HP230LSDUC-IRheem0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC6215864373
5178ML09HP115GEN-OMAINLINE · ML Serieswith ductless indoor unit ML09HP115GEN-IRheem1 ton9,000 Btu/h · Non-ducted1.9672%9.021.5CEE 25CEE 26XcelES CC2217970307
5179ML09HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML09HP230CALH-IRheem1 ton9,000 Btu/h · Non-ducted2.00113%14.633.3CEE 25CEE 26XcelES CC2215864345
5180ML09HP230GEN-OMAINLINE · ML Serieswith ductless indoor unit ML09HP230GEN-IRheem1 ton9,000 Btu/h · Non-ducted2.0770%9.121.2CEE 25CEE 26XcelES CC2215864327
5181ML09HP230NEX-OMAINLINE · ML Serieswith ductless indoor unit ML09HP230NEX-IRheem1 ton9,000 Btu/h · Ducted and non-ducted2.3382%13.024.6CEE 25CEE 26XcelES CC12215864334
5182ML09HP230NEXH-OMAINLINE · ML Serieswith ducted air handler ML09HP230LSDUC-IRheem1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.4CEE 25CEE 26XcelES CC12215864374
5183ML09HP230WIN-OMAINLINE · ML Serieswith ductless indoor unit ML09HP230WIN-IRheem1 ton9,000 Btu/h · Non-ducted2.1670%9.719.0CEE 25CEE 26XcelES CC2215864321
5184ML12HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML12HP230CALH-IRheem1 ton12,000 Btu/h · Non-ducted2.00113%12.729.4CEE 25CEE 26XcelES CC2215864346
5185ML12HP230GEN-OMAINLINE · ML Serieswith ductless indoor unit ML12HP230GEN-IRheem1 ton12,000 Btu/h · Non-ducted1.9170%9.121.3CEE 25CEE 26XcelES CC2217970308
5186ML12HP230NEX-OMAINLINE · ML Serieswith ductless indoor unit ML12HP230CON-IRheem1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.6CEE 25CEE 26XcelES CC12215864362
5187ML12HP230NEXH-OMAINLINE · ML Serieswith ductless indoor unit ML12HP230STDCAS-IRheem1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.2CEE 25CEE 26XcelES CC12215864370
5188ML18HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML18HP230CALH-IRheem1.5 tons18,000 Btu/h · Non-ducted2.34113%—25.6XcelES CC2215864347
5189ML18HP230GEN-OMAINLINE · ML Serieswith ductless indoor unit ML18HP230GEN-IRheem1.5 tons18,000 Btu/h · Non-ducted2.1570%9.619.2CEE 25CEE 26XcelES CC2217970309
5190ML18HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML18HP230G3AHU-IRheem1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC19216623398
5191ML18HP230MUL - OMAINLINE · ML SeriesRheem1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC6217607317
5192ML18HP230MUL-O*MAINLINE · ML SeriesRheem1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC3216623555
5193ML18HP230MULH-OMAINLINE · ML SeriesRheem1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.0CEE 25CEE 26XcelES CC6215864421
5194ML18HP230MULH-O*MAINLINE · ML SeriesRheem1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.0CEE 25CEE 26XcelES CC3216623565
5195ML18HP230NEX-OMAINLINE · ML Serieswith ducted air handler ML18HP230HSDUC-IRheem1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.320.0CEE 25CEE 26XcelES CC16215864359
5196ML18HP230NEXH-OMAINLINE · ML Serieswith ducted air handler ML18HP230AHU-IRheem1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.018.0CEE 25CEE 26XcelES CC16215864295
5197ML24HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML24HP230CALH-IRheem2 tons24,000 Btu/h · Non-ducted2.3483%13.521.0CEE 25CEE 26XcelES CC2215864348
5198ML24HP230GEN-OMAINLINE · ML Serieswith ductless indoor unit ML24HP230GEN-IRheem2 tons24,000 Btu/h · Non-ducted2.1471%9.318.7CEE 25CEE 26XcelES CC2215864330
5199ML24HP230LMNT-OMAINLINE · ML Serieswith ducted air handler ML24HP230WMAHU-IRheem2 tons24,000 Btu/h · Ducted1.9678%10.417.4CEE 25CEE 26XcelES CC19216623409
5200ML24HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML24HP230G3AHU-IRheem2 tons24,000 Btu/h · Ducted2.1486%10.018.6CEE 25CEE 26XcelES CC21216623399

Explore qualifying models by COP at 5°F