Both views use the same certified data. This device remembers your choice.
Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.
Simple view, for homeowners: top picks by size and what each rating measures →
Xcel EnergyData as of updated · sources
- Share of models
- 52.7%
- Qualifying models
- 7,174
- Qualifying certifications
- 197,833
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|
| DuctedDucted equipment only | ≥ 15.2 | ≥ 10 | ≥ 1.75 | ≥ 70% |
| Non-ductedNon-ducted equipment only | ≥ 16 | ≥ 9 | ≥ 1.75 | ≥ 70% |
Where the thresholds fall
Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: Xcel 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Xcel 70% | 70% |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: Ducted 15.2 | 15.2 |
| Baseline: Non-ducted 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Non-ducted 9 | 9.0 |
| Baseline: Ducted 10 | 10.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.7% · 3,292 of 5,427
- 2 tons59.4% · 1,152 of 1,941
- 2.5 to 3 tons50.4% · 1,483 of 2,942
- 3.5 to 4.5 tons42.2% · 1,195 of 2,834
- 5 tons and up10.9% · 52 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.7% · 3,292 of 5,427 |
| 2 tons | 59.4% · 1,152 of 1,941 |
| 2.5 to 3 tons | 50.4% · 1,483 of 2,942 |
| 3.5 to 4.5 tons | 42.2% · 1,195 of 2,834 |
| 5 tons and up | 10.9% · 52 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.2% | 2,070 / 6,438 |
| Non-ducted | 61.3% | 2,978 / 4,861 |
| Ducted and non-ducted | 91.6% | 2,126 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 387 of 555 | 69.7% |
| Carrier | 246 of 846 | 29.1% |
| TCL | 138 of 192 | 71.9% |
| BlueRidge | 132 of 194 | 68% |
| Daikin | 125 of 410 | 30.5% |
| AUX | 124 of 189 | 65.6% |
| Lennox | 121 of 341 | 35.5% |
| Ephoca | 120 of 382 | 31.4% |
| Innova | 120 of 382 | 31.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1276W5HDM48K1X6AGrandaire · W5H Series | Carrier | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 218854070 |
| 1277W5HDM53K1X6AGrandaire · W5H Series | Carrier | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218854074 |
| 1278WD5CUHAH18AAK+TIC2025-0016GRANDAIREwith ducted air handler FM(C,U)5Z30**AL | Carrier | 1.5 tons18,400 Btu/h · Ducted | 2.04 | 83% | 9.0 | 16.0 | CEE 25CEE 26Xcel | 111 | 217399873 |
| 1279WD5CUHAH24AAKGRANDAIREwith ducted air handler FMA5X24**AL | Carrier | 2 tons22,600 Btu/h · Ducted | 2.10 | 91% | 9.0 | 17.0 | CEE 25CEE 26Xcel | 250 | 216739138 |
| 1280WD5CUHAH24AAK+TIC2025-0016GRANDAIREwith ducted air handler CP2403A*+TXV+TD | Carrier | 2 tons23,400 Btu/h · Ducted | 2.00 | 78% | 8.9 | 15.2 | Xcel | 4 | 218004343 |
| 1281XH936E2C11KENMORE · LX SERIESwith indoor coil CTF36B5ADS2+CC and furnace Z8VT080B12SMPC1 | Carrier | 3 tons35,200 Btu/h · Ducted | 2.00 | 94% | 9.5 | 18.0 | CEE 25CEE 26Xcel | 32 | 218601892 |
| 1282XH960E2C11KENMORE · LX SERIESwith indoor coil CTF60C5CGS2+CC and furnace Z8VT120C20SMPC1 | Carrier | 4 tons47,000 Btu/h · Ducted | 2.00 | 94% | 8.5 | 21.0 | CEE 25CEE 26Xcel | 34 | 218601869 |
| 1283A-VHP06SA-1CENTURY · A Serieswith ductless indoor unit B-VHP061A-1 | Century | 0.5 tons6,500 Btu/h · Non-ducted | 2.40 | 109% | 12.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217482454 |
| 1284A-VHP09SA-1CENTURY · A Serieswith ducted air handler B-VHP09DA-1 | Century | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.85 | 120% | 13.8 | 20.5 | CEE 25CEE 26XcelES CC | 5 | 217482458 |
| 1285A-VHP12SA-1CENTURY · A Serieswith ductless indoor unit B-VHP121A-1 | Century | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 92% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 5 | 217482459 |
| 1286A-VHP183A-1CENTURY · A Series | Century | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 95% | 10.4 | 25.0 | CEE 25CEE 26XcelES CC | 3 | 218425159 |
| 1287A-VHP18SA-1CENTURY · A Serieswith ducted air handler B-VHP18AA-1 | Century | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.20 | 92% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 7 | 217482410 |
| 1288A-VHP24SA-1CENTURY · A Serieswith ductless indoor unit B-VHP24SA-1 | Century | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.34 | 83% | 13.5 | 21.0 | CEE 25CEE 26XcelES CC | 5 | 218425157 |
| 1289A-VHP284A-1CENTURY · A Series | Century | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.5 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 218425162 |
| 1290A-VHP33SA-1CENTURY · A Serieswith ductless indoor unit B-VHP33SA-1 | Century | 3 tons33,000 Btu/h · Non-ducted | 1.98 | 97% | 10.5 | 19.5 | CEE 25CEE 26XcelES CC | 1 | 218425158 |
| 1291A-VHP365A-1CENTURY · A Series | Century | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 100% | 10.7 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 218425165 |
| 1292A-VHP486A-1CENTURY · A Series | Century | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 218425168 |
| 1293A-VHP556A-1CENTURY · A Series | Century | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218425172 |
| 1294A-VXP18SA-1CENTURY · A Serieswith ducted air handler WXP18SA | Century | 1.5 tons18,000 Btu/h · Ducted | 2.10 | 103% | 10.8 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217482412 |
| 1295A-VXP24SA-1CENTURY · A Serieswith ducted air handler WXP24SA | Century | 2 tons24,000 Btu/h · Ducted | 1.96 | 78% | 10.5 | 17.5 | CEE 25CEE 26XcelES CC | 4 | 217482413 |
| 1296A-VXP30SA-1CENTURY · A Serieswith ducted air handler WXP30SA | Century | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 100% | 10.2 | 17.5 | CEE 25CEE 26XcelES CC | 8 | 217482414 |
| 1297A-VXP36SA-1CENTURY · A Serieswith ducted air handler B-VXP36SA-1 | Century | 3 tons36,000 Btu/h · Ducted | 1.90 | 105% | 10.3 | 17.4 | CEE 25CEE 26XcelES CC | 7 | 217169707 |
| 1298A-VXP48SA-1CENTURY · A Serieswith ducted air handler B-VXP48SA-1 | Century | 4 tons48,000 Btu/h · Ducted | 1.90 | 92% | 9.5 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 217169708 |
| 1299A-VXP60SA-1CENTURY · A Serieswith ducted air handler MXP48/60D1A | Century | 4 tons47,000 Btu/h · Ducted | 1.83 | 74% | 8.1 | 15.2 | CEE 25CEE 26XcelES CC | 3 | 217169739 |
| 1300A-ZHP09SA-1CENTURY · A-ZHP Serieswith ductless indoor unit B-ZHP09SA-1 | Century | 1 ton9,000 Btu/h · Non-ducted | 2.00 | 113% | 14.6 | 33.3 | CEE 25CEE 26XcelES CC | 1 | 218404564 |